Note
The following overall dimensions and dimension drawings are only applicable for self-ventilated 1LA7/1LA5 and 1LG6 motors with special insulation for voltages up to 690 V. For overall dimensions of 1LA8/1PQ8 motors with special insulation for voltages up to 690 V, see the section “Non-standard motors”.
For overall dimensions and dimension drawings for surface-cooled motors with standard insulation for voltages up to 500 V, see the relevant section.
Overall dimensions
Frame size |
Type |
Number of poles |
Dimensions |
|
|
|
|
---|---|---|---|---|---|---|---|
100 L |
1LA7 |
372 |
135 |
100 |
196 |
2 x M32 x 1.5 | |
112 M |
1LA7 |
393 |
148 |
112 |
226 |
2 x M32 x 1.5 | |
132 S/132 M |
1LA7 |
452.5 |
167 |
132 |
256 |
2 x M32 x 1.5 | |
160 M/160 L |
1LA7 |
588 |
197 |
160 |
300 |
2 x M40 x 1.5 | |
180 M/180 L |
1LA5 |
712 |
258 |
180 |
339 |
2 x M40 x 1.5 | |
1LG6 183 |
2 |
720 |
262 |
180 |
339 |
2 x M40 x 1.5 | |
1LG6 183 |
4 |
669 |
262 |
180 |
339 |
2 x M40 x 1.5 | |
1LG6 186 |
4, 6, 8 |
720 |
262 |
180 |
339 |
2 x M40 x 1.5 | |
200 L |
1LA5 |
769,5 |
305 |
200 |
388 |
2 x M50 x 1.5 | |
1LG6 206 |
720 |
300 |
200 |
378 |
2 x M50 x 1.5 | ||
1LG6 207 |
777 |
300 |
200 |
378 |
2 x M50 x 1.5 | ||
1LG6 207 |
4, 8 |
720 |
300 |
200 |
378 |
2 x M50 x 1.5 | |
225 S/225 M |
1LA5 |
806 |
305 |
225 |
426 |
2 x M50 x 1.5 | |
1LA5 |
2 |
776 |
305 |
225 |
426 |
2 x M50 x 1.5 | |
1LG6 220 |
4, 8 |
789 |
325 |
225 |
436 |
2 x M50 x 1.5 | |
1LG6 223 |
2 |
819 |
325 |
225 |
436 |
2 x M50 x 1.5 | |
1LG6 223 |
4, 6, 8 |
849 |
325 |
225 |
436 |
2 x M50 x 1.5 | |
1LG6 228 |
2 |
869 |
325 |
225 |
436 |
2 x M50 x 1.5 | |
1LG6 228 |
4, 6 |
899 |
325 |
225 |
436 |
2 x M50 x 1.5 | |
250 M |
1LG6 253 |
2, 6, 8 |
887 |
392 |
250 |
490 |
2 x M63 x 1.5 |
1LG6 253 |
4 |
957 |
392 |
250 |
490 |
2 x M63 x 1.5 | |
1LG6 258 |
2, 4, 6 |
957 |
392 |
250 |
490 |
2 x M63 x 1.5 | |
280 S/280 M |
1LG6 280 |
2, 4, 6, 8 |
960 |
432 |
280 |
540 |
2 x M63 x 1.5 |
1LG6 283 |
2, 4 |
1070 |
432 |
280 |
540 |
2 x M63 x 1.5 | |
1LG6 283 |
6, 8 |
960 |
432 |
280 |
540 |
2 x M63 x 1.5 | |
1LG6 288 |
2, 4, 6 |
1070 |
432 |
280 |
540 |
2 x M63 x 1.5 | |
315 S/315 M/315 L |
1LG6 310 |
2 |
1072 |
500 |
315 |
610 |
2 x M63 x 1.5 |
1LG6 310 |
4, 6, 8 |
1102 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 313 |
8 |
1102 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 313 |
2 |
1232 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 313 |
4, 6 |
1262 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 316 |
2 |
1232 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 316 |
4, 6, 8 |
1262 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 317 |
8 |
1262 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 317 |
2 |
1372 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 317 |
4, 6 |
1402 |
500 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 318 |
2 |
1372 |
651 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 318 |
4 |
1402 |
651 |
315 |
610 |
2 x M63 x 1.5 | |
1LG6 318 |
6, 8 |
1402 |
500 |
315 |
610 |
2 x M63 x 1.5 |
Notes on the dimensions
- Dimension designations according to DIN EN 50347 and IEC 60072.
- Fits
The shaft extensions specified in the dimension tables (DIN 748) and centering spigot diameters (DIN EN 50347) are machined with the following fits:
Dimension designation |
ISO fit DIN ISO 286-2 | |
---|---|---|
D, DA |
up to 30 |
j6 |
over 30 to 50 |
k6 | |
over 50 |
m6 | |
N |
up to 250 |
j6 |
over 250 |
h6 | |
F, FA |
h9 | |
K |
H17 | |
S |
Flange (FF) |
H17 |
The drilled holes of couplings and belt pulleys should have an ISO fit of at least H7.
- Dimension tolerances
For the following dimensions, the permissible deviations are given below:
Dimension designation |
Dimension |
Permitted deviation |
---|---|---|
H |
up to 250 |
–0.5 |
over 250 |
–1.0 | |
E, EA |
–0.5 |
Keyways and feather keyways (dimensions GA, GC, F and FA) are made in compliance with DIN 6885 Part 1.
- All dimensions are specified in mm.