Preliminary selection of the motor according to motor type/series, speed or number of poles, frame size, rated output, rated torque, rated speed and rated current
Self-ventilated motors for temperature/time classes F200 and F300
Speed (No. of poles) |
Frame size |
Rated output |
Rated speed |
Rated torque |
Rated current at 400 V |
---|---|---|---|---|---|
rpm |
kW |
rpm |
Nm |
A | |
Aluminum series 1LA7 and 1LA5, cast-iron series 1LG6 (motors with external fan) | |||||
3000, 2-pole |
80 M ... 315 L |
0.75 ... 200 |
2830 ... 2985 |
2.5 ... 640 |
2.1 ... 325 |
1500, 4-pole |
80 M ... 315 L |
0.55 ... 200 |
1395 ... 1488 |
3.7 ... 1284 |
1.86 ... 345 |
1000, 6-pole |
80 M ... 315 L |
0.37 ... 160 |
910 ... 990 |
3.9 ... 1543 |
1.2 ... 285 |
1500/3000, 4-/2-pole |
80 M ... 160 L |
The electrical data can be calculated and supplied on receipt of order. | |||
1000/1500, 6-/4-pole |
80 M ... 200 L |
||||
750/1500, 8-/4-pole |
80 M ... 200 L |
Forced-air cooled motors for temperature/time classes F200 and F300
Speed (No. of poles) |
Frame size |
Rated output |
Rated speed |
Rated torque |
Rated current at 400 V |
---|---|---|---|---|---|
rpm |
kW |
rpm |
Nm |
A | |
Aluminum series 1PP7 and 1PP5, cast-iron series 1PP6 (motors without an external fan) | |||||
3000, 2-pole |
80 M ... 315 L |
0.75 ... 200 |
2830 ... 2985 |
2.5 ... 640 |
2.1 ... 325 |
1500, 4-pole |
80 M ... 315 L |
0.55 ... 200 |
1395 ... 1488 |
3.7 ... 1284 |
1.86 ... 345 |
1000, 6-pole |
80 M ... 315 L |
0.37 ... 160 |
910 ... 990 |
3.9 ... 1543 |
1.2 ... 285 |
1500/3000, 4-/2-pole |
80 M ... 160 L |
The electrical data can be calculated and supplied on receipt of order. | |||
1000/1500, 6-/4-pole |
80 M ... 200 L |
||||
750/1500, 8-/4-pole |
80 M ... 200 L |
Self-ventilated motors for temperature/time class F400
Speed (No. of poles) |
Frame size |
Rated output |
Rated speed |
Rated torque |
Rated current at 400 V |
---|---|---|---|---|---|
rpm |
kW |
rpm |
Nm |
A | |
Cast-iron series 1LA6 and 1LG6 (motors with external fan) | |||||
3000, 2-pole |
100 L ... 315 L |
3 ... 190 |
2875 ... 2982 |
10 ... 608 |
6.5 ... 325 |
1500, 4-pole |
100 L ... 315 L |
2.2 ... 200 |
1410 ... 1490 |
15 ... 1284 |
5.5 ... 345 |
1000, 6-pole |
100 L ... 315 L |
1.5 ... 160 |
925 ... 990 |
15 ... 1546 |
4.5 ... 285 |
1500/3000, 4-/2-pole |
100 L ... 160 L |
The electrical data can be calculated and supplied on receipt of order. | |||
1000/1500, 6-/4-pole |
100 L ... 160 L |
||||
750/1500, 8-/4-pole |
100 L ... 160 L |
Forced-air cooled motors for temperature/time class F400
Speed (No. of poles) |
Frame size |
Rated output |
Rated speed |
Rated torque |
Rated current at 400 V |
---|---|---|---|---|---|
rpm |
kW |
rpm |
Nm |
A | |
Cast-iron series 1PP6 (motors without external fan) | |||||
3000, 2-pole |
100 L ... 315 L |
3 ... 190 |
2875 ... 2982 |
10 ... 608 |
6.5 ... 325 |
1500, 4-pole |
100 L ... 315 L |
2.2 ... 200 |
1410 ... 1490 |
15 ... 1284 |
5.5 ... 345 |
1000, 6-pole |
100 L ... 315 L |
1.5 ... 160 |
925 ... 990 |
15 ... 1546 |
4.5 ... 285 |
1500/3000, 4-/2-pole |
100 L ... 160 M |
The electrical data can be calculated and supplied on receipt of order. | |||
1000/1500, 6-/4-pole |
100 L ... 160 L |
||||
750/1500, 8-/4-pole |
100 L ... 160 L |