These "recommendations for drive selection" guide you step-by-step through this catalog to the required motor.
Step 1 |
Technical requirements for the motor | ||
---|---|---|---|
Determine the required product profile, the following are required: |
Rated frequency and rated voltage |
3 AC 50/60 Hz, | |
Duty |
Standard duty (continuous duty S1 according to DIN EN 60034-1) | ||
Degree of protection required |
IP.. | ||
Rated speed (No. of poles) |
n =................. rpm | ||
Rated output |
P =................. kW | ||
Rated torque |
M = P · 9550/n =................. Nm | ||
Type of construction |
IM.. | ||
Step 2 |
Environmental requirements for the motor |
||
Determine the installation conditions |
Ambient temperature |
? 40 °C |
>40 °C |
Site altitude |
?1000 m |
>1000 m | |
Factors for derating |
None |
Determine the factor for derating (for derating factor, see "Technical information" – "Coolant temperature and site altitude") | |
Step 3 |
For preliminary selection of the motor ? see subsequent pages and the corresponding "Preliminary selection of the motor" tables | ||
Determine the range of possible motors |
Select the frame size and therefore the possible motors on the basis of the following parameters: cooling method, degree of protection, rated output, rated speed and rated torque range. Note: The standard temperature range of the motors is from -20 to +40°C. | ||
Step 4 |
Detailed selection of the motor | ||
Determine the basic Order No. of the motor |
Determine the motor Order No. according to the following parameters: rated output, rated speed, rated torque and rated current from the "Selection and ordering data" for the motors that have already been identified as possibilities. | ||
Step 5 |
Selection of the special versions (see under "Special versions") | ||
Complete the motor Order No. |
Determine special versions and the associated Order codes (e.g. special voltages and types of construction, motor protection and degrees of protection, windings and insulation, colors and paint finish, mountings and mounting technology, etc.). | ||
Step 6 | |||
Select the frequency converter, if required |
For Order No. of the converter as well as its selection, see Catalogs D 11, D 11.1, DA 51.2 and DA 51.3. |
Order No. code
The order number consists of a combination of figures and letters and is divided into three blocks linked with hyphens for a better overview, e.g.
1LE1001-1DB20-1AA5-Z
H00
The first block (Positions 1 to 7) identifies the motor type; the second block (Positions 8 to 12) defines the motor frame size and length, the number of poles and in some cases the frequency/output; and in the third block (Positions 13 to 16), the frequency/output, type of construction and other design features are encoded.
For deviations in the second and third block from the catalog codes, either -Zor9 should be used as appropriate.
Ordering data:
- Complete Order No. and order code(s) or plain text.
- If a quotation has been requested, please specify the quotation number in addition to the Order No.
- When ordering a complete motor as a spare part, please specify the works serial No. for the previously supplied motor as well as the Order No.
Structure of the Order No.: |
Position: |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
? |
8 |
9 |
10 |
11 |
12 |
- |
13 |
14 |
15 |
16 |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC squirrel-cage motors, surface-cooled |
||||||||||||||||||||||||
Positions 1 to 4: Digit, letter, letter, digit |
New generation |
1 |
L |
E |
1 |
|||||||||||||||||||
Design or version (motor type)
|
||||||||||||||||||||||||
Positions 5 to 7: 3 digits |
|
0 |
0 |
1 |
||||||||||||||||||||
|
0 |
0 |
2 |
|||||||||||||||||||||
Positions 8, 9 and 11: Digit, letter, digit |
Motor frame size (frame size as a combination of shaft height and overall length, encoded) |
1 |
A..D |
0..6 |
||||||||||||||||||||
Position 10: Letter |
Number of poles A … D = 2-, 4-, 6-, 8-pole |
A..D |
||||||||||||||||||||||
Positions 12 and 13: 2 digits |
Voltage, circuit and frequency |
0..9 |
0..8 |
|||||||||||||||||||||
Position 14: Letter |
Type of construction (A … V) |
A..V |
||||||||||||||||||||||
Position 15: Letter |
Motor protection (A … Z; special versions encoded) |
A..Z |
||||||||||||||||||||||
Position 16: Digit |
Mechanical design (motor version and connection box position)
|
0
4 5 6 7 |
||||||||||||||||||||||
Special order versions: |
Z |
Ordering example
Selection criteria |
Requirement |
Structure of the Order No. |
---|---|---|
Motor type |
New generation Standard motor with high efficiency EFF1, |
1LE1001-?????-???? |
Motor frame size/No. of poles/speed |
4-pole/1500 rpm |
1LE1001-1DB2?-???? |
Rated output |
11 kW |
|
Voltage and frequency |
230 V?/400 VY, 50 Hz |
1LE1001-1DB22-2??? |
Type of construction |
IM V5 with protective cover1) |
1LE1001-1DB22-2C??-Z |
(Special versions) |
3 PTC thermistors |
1LE1001-1DB22-2CB?-Z |
Mechanical design |
Connection box on RHS |
1LE1001-1DB22-2CB5-Z |
Mounted separately driven fan |
1LE1001-1DB22-2CB5-Z |
1) Standard without protective cover – the protective cover is defined with OptionH00and this option must be ordered in addition.
2) No additional option must be specified in the order.
Determine themotor type according to cooling method, degree of protection and frame design (for further selection according to speed or number of poles, rated output, rated torque, rated speed and rated current, see the relevant "Preselection of the motor" tables)
Applications for surface-cooled motor types |
Cooling method |
Standard designation for degree of protection to DIN EN 60034 Part 5 |
Frame design |
Rated output at 50 Hz | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Motor frame sizes (shaft heights) | ||||||||||||
56 |
63 |
71 |
80 |
90 |
100 |
112 |
132 |
160 | ||||
General Line motors with shorter delivery time |
Self-ventilated |
IP55 |
Aluminum |
1.5 ... 18.5 kW | ||||||||
Energy-saving motors with improved efficiency (Improved Efficiency EFF2) |
Self-ventilated |
IP55 |
Aluminum |
0.75 ... 18.5 kW | ||||||||
Energy-saving motors with high efficiency (High Efficiency EFF1) |
Self-ventilated |
IP55 |
Aluminum |
0.75 ... 18.5 kW | ||||||||
Motors with increased output and improved efficiency |
Self-ventilated |
IP55 |
Aluminum |
2.2 ... 22 kW | ||||||||
Motors with increased output and high efficiency |
Self-ventilated |
IP55 |
Aluminum |
2.2 ... 22 kW | ||||||||
Motors without external fan and fan cover with improved efficiency |
Forced-air-cooled |
IP55 |
Aluminum |
0.75 ... 18.5 kW | ||||||||
Motors without external fan and fan cover with high efficiency |
Forced-air-cooled |
IP55 |
Aluminum |
0.75 ... 18.5 kW |