Siemens
(4872) 700-366
skenergo@mail.ru
Forced-air cooled, no external fan or fan cover, high efficiency
Order No. supplements

Motor type

Frame size

Positions 12 and 13: Voltages (voltage codes)

Standard voltages

Further voltages

50Hz

50 Hz

230V?/400VY

400V?/690VY

500VY

500V?

220V?/380VY

380V?/660VY

415VY

415V?

60Hz

Rated voltage range

460VY

460V?

(210230V?/360400VY)1)

(360400V?/625695VY)1)

(395435VY)1)

(395435V?)1)

see "Selection and ordering data" for outputs at 60Hz

22

34

27

40

21

33

23

35

1LE1001?1A..?????
F90

100L

O

O

O

O

?

?

?

?

1LE1001?1B..?????
F90

112M

O

O

O

O

?

?

?

?

1LE1001?1C..????Z
F90

132S/M

O

O

O

O

?

?

?

?

1LE1001?1D..????Z
F90

160M/L

O

O

O

O

?

?

?

?


OWithout additional charge

?With additional charge

Order other voltages with voltage code9 in position 12, code0 in position 13 and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Voltages").

1)A rated voltage range is also specified on the rating plate.

Motor type

Frame size

Position 14: Types of construction (type letter)

Without flange

With flange (acc. toDINEN50347)

IMB3
1) 2)

IMB6
2)

IMB7
2)

IMB8
2)

IMV6
2)

IMV5
without
protective cover
2)

Flange size

IMB5
2) 3

IMV1
wihout
protective cover
2)

IMV3
2)

IMB35

A

T

U

V

D

C

F

G

H

J

Order No. supplementZ
with order code

1LE1002?1A...?.?..?Z
F90

100L

?

?

?

?

?

?

FF215

?

?

?

?

1LE1002?1B...?.?..?Z
F90

112M

?

?

?

?

?

?

FF215

?

?

?

?

1LE1001?1C...?.?..?Z
F90

132S/M

?

?

?

?

?

?

FF265

?

?

?

?

1LE1001?1D...?.?..?Z
F90

160M/L

?

?

?

?

?

?

FF300

?

?

?

?


Motor type

Frame size

Position 14: Types of construction (type letter)

With standard flange (acc. toDINEN50347)

Flange size

IMB14
2)4)

IMV19
2)

IMV18
wihout
protective cover
2)

IMB34

K

L

M

N

Order No. supplementZ
with order code

1LE1001?1A...?.?..?Z
F90

100L

FT130

?

?

?

?

1LE1001?1B...?.?..?Z
F90

112M

FT130

?

?

?

?

1LE1001?1C...?.?..?Z
F90

132S/M

FT165

?

?

?

?

1LE1001?1D...?.?..?Z
F90

160M/L

FT215

?

?

?

?


?Standard version

?With additional charge

1)The types of construction IMB6/7/8, IMV6 and IMV5 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IMB3 is then stamped on the rating plate.

2)The type of construction is stamped on the rating plate. When ordering with condensation drainage holes (order codeH03), it is absolutely necessary to specify the type of construction for the exact position of the condensation drainage holes during manufacture.

3)The types of construction IMV3 and IMV1 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IMB5 is then stamped on the rating plate.

4)The types of construction IMV19 and IMV18 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IMB14 is then stamped on the rating plate.

Motor type

Frame size

Position 15: Motor protection (motor protection letter)

Without
motor protection

Motor protection with PTC thermistors with 3 embedded temperature sensors
for tripping1)

Motor protection with PTC thermistors with 6 embedded temperature sensors
for alarm and tripping1)

Motor temperature detection with embedded temperature sensor
KTY 84-1301)

NTC thermistors for tripping

Temperature detectors for tripping1)

A

B

C

F

Z

Z

Order code

Q2A

Q3A

1LE1001?1A...?..?.?Z
F90

100L

?

?

?

?

?

?

1LE1001?1B...?..?.?Z
F90

112M

?

?

?

?

?

?

1LE1001?1C...?..?.?Z
F90

132S/M

?

?

?

?

?

?

1LE1001?1D...?..?.?Z
F90

160M/L

?

?

?

?

?

?


?Standard version

?With additional charge

1)For appropriate tripping unit, see Catalog LV1.

Motor type

Motor frame size

Position 16: Connection box (connection box code)

Connection box
top1)

Connection box
on RHS2)

Connection box
on LHS2)

Connection box
bottom2)

4

5

6

7

1LE1001?1A...?...??Z
F90

100L

?

?

?

?

1LE1001?1B...?...??Z
F90

112M

?

?

?

?

1LE1001?1C...?...??Z
F90

132S/M

?

?

?

?

1LE1001?1D...?...??Z
F90

160M/L

?

?

?

?


?Standard version

?With additional charge

1) With type of construction, cast feet as standard. Screwed-on feet are available with order codeH01, see "Special versions".

2) With type of construction, screwed-on feet as standard.



  © " " 2007-2016
  (4872) 700-366
.