Order No. supplements
Motor type |
Frame size |
Positions 12 and 13: Voltages (voltage codes) | |||||||
---|---|---|---|---|---|---|---|---|---|
Standard voltages |
Further voltages | ||||||||
50 Hz |
50 Hz |
||||||||
230 V?/400 VY |
400 V?/690 VY |
500 VY |
500 V? |
220 V?/380 VY |
380 V?/660 VY |
415 VY |
415 V? | ||
60 Hz |
Rated voltage range | ||||||||
460 VY |
460 V? |
(210 … 230 V?/360 … 400 VY) 1) |
(360 … 400 V?/625 … 695 VY) 1) |
(395 … 435 VY) 1) |
(395 … 435 V?) 1) | ||||
see "Selection and ordering data" for outputs at 60 Hz |
|||||||||
22 |
34 |
27 |
40 |
21 |
33 |
23 |
35 | ||
1LE1001?1A..???…?? |
100 L |
O |
O |
O |
O |
? |
? |
? |
? |
1LE1001?1B..???…?? |
112 M |
O |
O |
O |
O |
? |
? |
? |
? |
1LE1001?1C..???…?Z |
132 S/M |
O |
O |
O |
O |
? |
? |
? |
? |
1LE1001?1D..???…?Z |
160 M/L |
O |
O |
O |
O |
? |
? |
? |
? |
O Without additional charge
? With additional charge
Order other voltages with voltage code9 in position 12, code0 in position 13 and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Voltages").
1) A rated voltage range is also specified on the rating plate.
Motor type |
Frame size |
Position 14: Types of construction (type letter) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Without flange |
With flange (acc. to DIN EN 50347) | ||||||||||||
IM B3 |
IM B6 |
IM B7 |
IM B8 |
IM V6 |
IM V5 |
Flange size |
IM B5 |
IM V1 |
IM V3 |
IM B35 | |||
A |
T |
U |
V |
D |
C |
F |
G |
H |
J | ||||
Order No. supplement –Z |
– |
– |
– |
– |
– |
– |
– |
– |
– |
– |
– | ||
1LE1002?1A...?.?..?Z |
100 L |
? |
? |
? |
? |
? |
? |
FF 215 |
? |
? |
? |
? | |
1LE1002?1B...?.?..?Z |
112 M |
? |
? |
? |
? |
? |
? |
FF 215 |
? |
? |
? |
? | |
1LE1001?1C...?.?..?Z |
132 S/M |
? |
? |
? |
? |
? |
? |
FF 265 |
? |
? |
? |
? | |
1LE1001?1D...?.?..?Z |
160 M/L |
? |
? |
? |
? |
? |
? |
FF 300 |
? |
? |
? |
? |
Motor type |
Frame size |
Position 14: Types of construction (type letter) | |||||
---|---|---|---|---|---|---|---|
With standard flange (acc. to DIN EN 50347) | |||||||
Flange size |
IM B14 |
IM V19 |
IM V18 |
IM B34 | |||
K |
L |
M |
N | ||||
Order No. supplement –Z |
– |
– |
– |
– |
– | ||
1LE1001?1A...?.?..?Z |
100 L |
FT 130 |
? |
? |
? |
? | |
1LE1001?1B...?.?..?Z |
112 M |
FT 130 |
? |
? |
? |
? | |
1LE1001?1C...?.?..?Z |
132 S/M |
FT 165 |
? |
? |
? |
? | |
1LE1001?1D...?.?..?Z |
160 M/L |
FT 215 |
? |
? |
? |
? |
? Standard version
? With additional charge
1) The types of construction IM B6/7/8, IM V6 and IM V5 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B3 is then stamped on the rating plate.
2) The type of construction is stamped on the rating plate. When ordering with condensation drainage holes (order codeH03), it is absolutely necessary to specify the type of construction for the exact position of the condensation drainage holes during manufacture.
3) The types of construction IM V3 and IM V1 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B5 is then stamped on the rating plate.
4) The types of construction IM V19 and IM V18 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B14 is then stamped on the rating plate.
Motor type |
Frame size |
Position 15: Motor protection (motor protection letter) | ||||||
---|---|---|---|---|---|---|---|---|
Without |
Motor protection with PTC thermistors with 3 embedded temperature sensors |
Motor protection with PTC thermistors with 6 embedded temperature sensors |
Motor temperature detection with embedded temperature sensor |
NTC thermistors for tripping |
Temperature detectors for tripping1) | |||
A |
B |
C |
F |
Z |
Z | |||
Order code |
Q2A |
Q3A | ||||||
1LE1001?1A...?..?.?Z |
100 L |
? |
? |
? |
? |
? |
? | |
1LE1001?1B...?..?.?Z |
112 M |
? |
? |
? |
? |
? |
? | |
1LE1001?1C...?..?.?Z |
132 S/M |
? |
? |
? |
? |
? |
? | |
1LE1001?1D...?..?.?Z |
160 M/L |
? |
? |
? |
? |
? |
? |
? Standard version
? With additional charge
1) For appropriate tripping unit, see Catalog LV 1.
Motor type |
Motor frame size |
Position 16: Connection box (connection box code) | |||
---|---|---|---|---|---|
Connection box |
Connection box |
Connection box |
Connection box | ||
4 |
5 |
6 |
7 | ||
1LE1001?1A ...?...??Z |
100 L |
? |
? |
? |
? |
1LE1001?1B ...?...??Z |
112 M |
? |
? |
? |
? |
1LE1001?1C ...?...??Z |
132 S/M |
? |
? |
? |
? |
1LE1001?1D ...?...??Z |
160 M/L |
? |
? |
? |
? |
? Standard version
? With additional charge
1) With type of construction, cast feet as standard. Screwed-on feet are available with order codeH01, see "Special versions".