Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
(4872) 700-366
skenergo@mail.ru
Forced-air cooled, no external fan or fan cover, high efficiency
Order No. supplements

Motor type

Frame size

Positions 12 and 13: Voltages (voltage codes)

Standard voltages

Further voltages

50 Hz

50 Hz

230 V?/400 VY

400 V?/690 VY

500 VY

500 V?

220 V?/380 VY

380 V?/660 VY

415 VY

415 V?

60 Hz

Rated voltage range

460 VY

460 V?

(210 … 230 V?/360 … 400 VY) 1)

(360 … 400 V?/625 … 695 VY) 1)

(395 … 435 VY) 1)

(395 … 435 V?) 1)

see "Selection and ordering data" for outputs at 60 Hz

22

34

27

40

21

33

23

35

1LE1001?1A..???…??
F90

100 L

1LE1001?1B..???…??
F90

112 M

1LE1001?1C..???…?Z
F90

132 S/M

1LE1001?1D..???…?Z
F90

160 M/L


O Without additional charge

? With additional charge

Order other voltages with voltage code9 in position 12, code0 in position 13 and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Voltages").

1) A rated voltage range is also specified on the rating plate.

Motor type

Frame size

Position 14: Types of construction (type letter)

Without flange

With flange (acc. to DIN EN 50347)

IM B3
1) 2)

IM B6
2)

IM B7
2)

IM B8
2)

IM V6
2)

IM V5
without
protective cover
2)

Flange size

IM B5
2) 3

IM V1
wihout
protective cover
2)

IM V3
2)

IM B35

A

T

U

V

D

C

F

G

H

J

Order No. supplement –Z
with order code

1LE1002?1A...?.?..?Z
F90

100 L

FF 215

1LE1002?1B...?.?..?Z
F90

112 M

FF 215

1LE1001?1C...?.?..?Z
F90

132 S/M

FF 265

1LE1001?1D...?.?..?Z
F90

160 M/L

FF 300


Motor type

Frame size

Position 14: Types of construction (type letter)

With standard flange (acc. to DIN EN 50347)

Flange size

IM B14
2) 4)

IM V19
2)

IM V18
wihout
protective cover
2)

IM B34

K

L

M

N

Order No. supplement –Z
with order code

1LE1001?1A...?.?..?Z
F90

100 L

FT 130

1LE1001?1B...?.?..?Z
F90

112 M

FT 130

1LE1001?1C...?.?..?Z
F90

132 S/M

FT 165

1LE1001?1D...?.?..?Z
F90

160 M/L

FT 215


? Standard version

? With additional charge

1) The types of construction IM B6/7/8, IM V6 and IM V5 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B3 is then stamped on the rating plate.

2) The type of construction is stamped on the rating plate. When ordering with condensation drainage holes (order codeH03), it is absolutely necessary to specify the type of construction for the exact position of the condensation drainage holes during manufacture.

3) The types of construction IM V3 and IM V1 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B5 is then stamped on the rating plate.

4) The types of construction IM V19 and IM V18 without protective cover are also possible as long as no condensation drainage holes (order codeH03) and no stamping of these types of construction on the rating plate are required. As standard, the type of construction IM B14 is then stamped on the rating plate.

Motor type

Frame size

Position 15: Motor protection (motor protection letter)

Without
motor protection

Motor protection with PTC thermistors with 3 embedded temperature sensors
for tripping1)

Motor protection with PTC thermistors with 6 embedded temperature sensors
for alarm and tripping1)

Motor temperature detection with embedded temperature sensor
KTY 84-1301)

NTC thermistors for tripping

Temperature detectors for tripping1)

A

B

C

F

Z

Z

Order code

Q2A

Q3A

1LE1001?1A...?..?.?Z
F90

100 L

1LE1001?1B...?..?.?Z
F90

112 M

1LE1001?1C...?..?.?Z
F90

132 S/M

1LE1001?1D...?..?.?Z
F90

160 M/L


? Standard version

? With additional charge

1) For appropriate tripping unit, see Catalog LV 1.

Motor type

Motor frame size

Position 16: Connection box (connection box code)

Connection box
top 1)

Connection box
on RHS 2)

Connection box
on LHS 2)

Connection box
bottom 2)

4

5

6

7

1LE1001?1A ...?...??Z
F90

100 L

1LE1001?1B ...?...??Z
F90

112 M

1LE1001?1C ...?...??Z
F90

132 S/M

1LE1001?1D ...?...??Z
F90

160 M/L


? Standard version

? With additional charge

1) With type of construction, cast feet as standard. Screwed-on feet are available with order codeH01, see "Special versions".

2) With type of construction, screwed-on feet as standard.


Каталог оборудования

Приводная техника

Двигатели переменного тока

Низковольтные двигатели

Low-Voltage Motors - IEC Squirrel-Cage Motors

1LE1 motor generation

Orientation

Forced-air cooled, no external fan or fan cover, high efficiency

Special versions

Accessories and spare parts

Dimensions

Standard motors up to frame size 315 L

Non-standard motors frame size 315 and above

Explosion-proof motors

Motors operating with frequency converters

Pump motors

Fan motors

Compressor motors

Smoke-extraction motors

Marine motors

Синхронные двигатели с возбуждением от постояннымх магнитов

Асинхронные серводвигатели/двигатели главного движения

Синхронные двигатели

Моментные двигатели 1FW

Мотор-шпиндель 2SP1 ECS

Линейные двигатели

Линейные двигатели 1FN

Шаговые двигатели 1FL3 SIMOSTEP

Системы измерения

Стояночный тормоз

Асинхронные двигатели - стандартная линия

Двигатели постоянного тока

Децентрализованная приводная техника

Преобразователи

Преобразователи постоянного тока

Инструментальное программное обеспечение

Дополнительные компоненты

Техника автоматизации

Коммуникации и сети

Низковольтная коммутационная техника

Электроустановочная техника

Специализированные сенсоры

Блоки питания

Технология безопасности

Системные решения и продукты для отраслей

Сервис

Автоматизация процесса

... и все, что Вам еще необходимо


  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика