Article number | 6GK5302-7GD00-1EA3 | 6GK5302-7GD00-1GA3 | 6GK5302-7GD00-2EA3 | 6GK5302-7GD00-2GA3 |
|---|
Transmission rate | | | | | Transfer rate | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | Interfaces for communication integrated | | | | | Number of electrical connections | | | | | | 2 | 2 | 2 | 2 | Number of 10/100/1000 Mbit/s RJ45 ports Integrated | 2 | 2 | 2 | 2 | Number of 100 Mbit/s SC ports | | | | | | 0 | 0 | 0 | 0 | Number of 100 Mbit/s LC ports | | | | | | | | 7 | 7 | Number of 1000 Mbit/s LC ports | | | | | | 0 | 0 | 0 | 0 | | 7 | | | | Interfaces others | | | | | Number of electrical connections | | | | | | 1 | 1 | 2 | 2 | | 1 | 1 | 2 | 2 | | 1 | 1 | 2 | 2 | Type of electrical connection | | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 2 x 4-pole terminal block | 2 x 4-pole terminal block | design of the removable storage | | | | | | Yes | Yes | Yes | Yes | Signal-Inputs/outputs | | | | | Operating voltage of the signaling contacts | | | | | | 24V | 24V | 24V | 24V | Operating current of the signaling contacts | | | | | | 0.1A | 0.1A | 0.1A | 0.1A | Supply voltage, current consumption, power loss | | | | | Type of voltage supply redundant power supply unit | No | No | Yes | Yes | Type of voltage of the supply voltage | DC | DC | DC | DC | Supply voltage | | | | | | 24V | 24V | 24V | 24V | | 19.2V | 19.2V | 19.2V | 19.2V | | 57.6V | 57.6V | 57.6V | 57.6V | Supply voltage 2 Rated value | | | | | | DC | DC | DC | DC | Supply voltage at DC | 24V | 24V | 24V | 24V | | 19.2...57.6V | 19.2...57.6V | 19.2...57.6V | 19.2...57.6V | Product component fusing at power supply input | Yes | Yes | Yes | Yes | Fuse protection type at input for supply voltage | T 4 A / 125 V | T 4 A / 125 V | T 4 A / 125 V | T 4 A / 125 V | Consumed current maximum | 0.75A | 0.75A | 0.75A | 0.75A | Power loss [W] | | | | | | 17W | 17W | 17W | 17W | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | Relative humidity | | | | | | 95% | 95% | 95% | 95% | Protection class IP | IP30 | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | | Design | compact | compact | compact | compact | Width | 216mm | 216mm | 216mm | 216mm | Height | 143mm | 143mm | 143mm | 143mm | Depth | 110mm | 110mm | 110mm | 110mm | Net weight | 1.8kg | 1.8kg | 2.03kg | 1.8kg | Product feature conformal coating | No | Yes | No | Yes | Mounting type | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | Product properties, functions, components general | | | | | Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s | 100 | 100 | 100 | 100 | Cascading in cases of star topology | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | Product functions management, configuration | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Identification & maintenance function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Diagnosis | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions VLAN | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | | Yes | Yes | Yes | Yes | Number of VLANs maximum | 255 | 255 | 255 | 255 | Number of VLANs - dynamic maximum | 255 | 255 | 255 | 255 | Protocol is supported GVRP | Yes | Yes | Yes | Yes | Product functions DHCP | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Redundancy | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported Media Redundancy Protocol (MRP) | Yes | Yes | Yes | Yes | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Security | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | Product functions Time | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals | | | | | Standard | | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | | UL 508 | UL 508 | UL 508 | UL 508 | | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | Standards, specifications, approvals CE | | | | | Certificate of suitability CE marking | Yes | Yes | Yes | Yes | Standard | | | | | | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | Standards, specifications, approvals miscellaneous | | | | | Certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | | Yes | Yes | Yes | Yes | | No | No | No | No | | | | | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals ship classification | | | | | Marine classification association | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | No | No | No | | Yes | No | No | No | Standards, specifications, approvals product conformity | | | | | MTBF at 40 C | 27.2y | 27.2y | 19.6y | 19.6y |
Article number | 6GK5302-7GD00-3EA3 | 6GK5302-7GD00-3GA3 | 6GK5302-7GD00-4EA3 | 6GK5302-7GD00-4GA3 |
|---|
Transmission rate | | | | | Transfer rate | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | Interfaces for communication integrated | | | | | Number of electrical connections | | | | | | 2 | 2 | 2 | 2 | Number of 10/100/1000 Mbit/s RJ45 ports Integrated | 2 | 2 | 2 | 2 | Number of 100 Mbit/s SC ports | | | | | | 0 | 0 | 0 | 0 | Number of 100 Mbit/s LC ports | | | | | | 7 | 7 | 7 | 7 | Number of 1000 Mbit/s LC ports | | | | | | 0 | 0 | 0 | 0 | Interfaces others | | | | | Number of electrical connections | | | | | | 1 | 1 | 2 | 2 | | 1 | 1 | 1 | 1 | | | | 1 | 1 | Type of electrical connection | | | | | | 3-pole terminal block | 3-pole terminal block | 3-pole terminal block | 3-pole terminal block | | 3-pole terminal block | 3-pole terminal block | 2 x 3-pole terminal block | 2 x 3-pole terminal block | design of the removable storage | | | | | | Yes | Yes | Yes | Yes | Signal-Inputs/outputs | | | | | Operating voltage of the signaling contacts | | | | | | 276V | 276V | 276V | 276V | | 230V | 230V | 230V | 230V | Operating current of the signaling contacts | | | | | | 5A | 5A | 5A | 5A | | 0.1A | 0.1A | 0.1A | 0.1A | Supply voltage, current consumption, power loss | | | | | Type of voltage supply redundant power supply unit | No | No | Yes | Yes | Type of voltage of the supply voltage | AC | AC | AC | AC | Supply voltage | | | | | | 230V | 230V | 230V | 230V | | 80...276V | 80...276V | 80...276V | 80...276V | Supply voltage 2 Rated value | | | | | | DC | DC | DC | DC | Supply voltage at DC | 220V | 220V | 220V | 220V | | 46.25...300V | 46.25...300V | 46.25...300V | 46.25...300V | Product component fusing at power supply input | Yes | Yes | Yes | Yes | Fuse protection type at input for supply voltage | T 2 A / 250 V | T 2 A / 250 V | T 2 A / 250 V | T 2 A / 250 V | Consumed current maximum | 0.08A | 0.08A | 0.08A | 0.08A | Power loss [W] | | | | | | 18W | 18W | 18W | 18W | | 18W | 18W | 18W | 18W | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | Relative humidity | | | | | | 95% | 95% | 95% | 95% | Protection class IP | IP30 | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | | Design | compact | compact | compact | compact | Width | 216mm | 216mm | 216mm | 216mm | Height | 143mm | 143mm | 143mm | 143mm | Depth | 110mm | 110mm | 110mm | 110mm | Net weight | 1.85kg | 1.85kg | 2.12kg | 2.12kg | Product feature conformal coating | No | Yes | No | Yes | Mounting type | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | Product properties, functions, components general | | | | | Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s | 100 | 100 | 100 | 100 | Cascading in cases of star topology | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | Product functions management, configuration | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Identification & maintenance function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Diagnosis | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions VLAN | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | | Yes | Yes | Yes | Yes | Number of VLANs maximum | 255 | 255 | 255 | 255 | Number of VLANs - dynamic maximum | 255 | 255 | 255 | 255 | Protocol is supported GVRP | Yes | Yes | Yes | Yes | Product functions DHCP | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Redundancy | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported Media Redundancy Protocol (MRP) | Yes | Yes | Yes | Yes | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Security | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | Product functions Time | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals | | | | | Standard | | | | | | - | - | - | - | | UL 508, CSA C22.2 No. 142-M1987 | UL 508, CSA C22.2 No. 142-M1987 | UL 508, CSA C22.2 No. 142-M1987 | UL 508, CSA C22.2 No. 142-M1987 | | - | - | - | - | | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | Standards, specifications, approvals CE | | | | | Certificate of suitability CE marking | Yes | Yes | Yes | Yes | Standard | | | | | | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | Standards, specifications, approvals miscellaneous | | | | | Certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals ship classification | | | | | Marine classification association | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | Standards, specifications, approvals product conformity | | | | | MTBF at 40 C | 22.8y | 22.8y | 15.3y | 15.3y |
Article number | 6GK5307-2FD00-1EA3 | 6GK5307-2FD00-1GA3 | 6GK5307-2FD00-2EA3 | 6GK5307-2FD00-2GA3 |
|---|
Transmission rate | | | | | Transfer rate | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | Interfaces for communication integrated | | | | | Number of electrical connections | | | | | | 7 | 7 | 7 | 7 | Number of 10/100 Mbit/s RJ45 ports Integrated | 5 | 5 | 5 | 5 | Number of 10/100/1000 Mbit/s RJ45 ports Integrated | 2 | 2 | 2 | 2 | Number of 100 Mbit/s SC ports | | | | | | 0 | 0 | 0 | 0 | Number of 100 Mbit/s LC ports | | | | | | 2 | 2 | 2 | 2 | Number of 1000 Mbit/s LC ports | | | | | | 0 | 0 | 0 | 0 | Interfaces others | | | | | Number of electrical connections | | | | | | 1 | 1 | 2 | 2 | | 1 | 1 | 2 | 2 | | 1 | 1 | 2 | 2 | Type of electrical connection | | | | | | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | 2-pole terminal block | | 4-pole terminal block | 4-pole terminal block | 2 x 4-pole terminal block | 2 x 4-pole terminal block | design of the removable storage | | | | | | Yes | Yes | Yes | Yes | Signal-Inputs/outputs | | | | | Operating voltage of the signaling contacts | | | | | | 24V | 24V | 24V | 24V | Operating current of the signaling contacts | | | | | | 0.1A | 0.1A | 0.1A | 0.1A | Supply voltage, current consumption, power loss | | | | | Type of voltage supply redundant power supply unit | No | No | Yes | Yes | Type of voltage of the supply voltage | DC | DC | DC | DC | Supply voltage | | | | | | 24V | 24V | 24V | 24V | | 19.2V | 19.2V | 19.2V | 19.2V | | 57.6V | 57.6V | 57.6V | 57.6V | Supply voltage 2 Rated value | | | | | | DC | DC | DC | DC | Supply voltage at DC | 24V | 24V | 24V | 24V | | 19.2...57.6V | 19.2...57.6V | 19.2...57.6V | 19.2...57.6V | Product component fusing at power supply input | Yes | Yes | Yes | Yes | Fuse protection type at input for supply voltage | T 4 A / 125 V | T 4 A / 125 V | T 4 A / 125 V | T 4 A / 125 V | Consumed current maximum | 0.75A | 0.75A | 0.75A | 0.75A | Power loss [W] | | | | | | 12W | 12W | 12W | 12W | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | Relative humidity | | | | | | 95% | 95% | 95% | 95% | Protection class IP | IP30 | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | | Design | compact | compact | compact | compact | Width | 216mm | 216mm | 216mm | 216mm | Height | 143mm | 143mm | 143mm | 143mm | Depth | 110mm | 110mm | 110mm | 110mm | Net weight | 1.8kg | 1.8kg | 2.03kg | 2.03kg | Product feature conformal coating | No | Yes | No | Yes | Mounting type | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | Product properties, functions, components general | | | | | Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s | 100 | 100 | 100 | 100 | Cascading in cases of star topology | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | Product functions management, configuration | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Identification & maintenance function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Diagnosis | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions VLAN | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | | Yes | Yes | Yes | Yes | Number of VLANs maximum | 255 | 255 | 255 | 255 | Number of VLANs - dynamic maximum | 255 | 255 | 255 | 255 | Protocol is supported GVRP | Yes | Yes | Yes | Yes | Product functions DHCP | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Redundancy | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported Media Redundancy Protocol (MRP) | Yes | Yes | Yes | Yes | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Security | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | Product functions Time | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals | | | | | Standard | | | | | | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4 | | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 | | UL 508 | UL 508 | UL 508 | UL 508 | | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4 | | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | Standards, specifications, approvals CE | | | | | Certificate of suitability CE marking | Yes | Yes | Yes | Yes | Standard | | | | | | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | Standards, specifications, approvals miscellaneous | | | | | Certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | | Yes | Yes | Yes | Yes | | No | No | No | No | | | | | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals ship classification | | | | | Marine classification association | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | Standards, specifications, approvals product conformity | | | | | MTBF at 40 C | 29.9y | 29.9y | 20.9y | 20.9y |
Article number | 6GK5307-2FD00-3EA3 | 6GK5307-2FD00-3GA3 | 6GK5307-2FD00-4EA3 | 6GK5307-2FD00-4GA3 |
|---|
Transmission rate | | | | | Transfer rate | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | 10Mbit/s,100Mbit/s,1000Mbit/s | Interfaces for communication integrated | | | | | Number of electrical connections | | | | | | 7 | 7 | 7 | 7 | Number of 10/100 Mbit/s RJ45 ports Integrated | 5 | 5 | 5 | 5 | Number of 10/100/1000 Mbit/s RJ45 ports Integrated | 2 | 2 | 2 | 2 | Number of 100 Mbit/s SC ports | | | | | | 0 | 0 | 0 | 0 | Number of 100 Mbit/s LC ports | | | | | | 2 | 2 | 2 | 2 | Number of 1000 Mbit/s LC ports | | | | | | 0 | 0 | 0 | 0 | Interfaces others | | | | | Number of electrical connections | | | | | | 1 | 1 | 2 | 2 | | 1 | 1 | 1 | 1 | | | | 1 | 1 | Type of electrical connection | | | | | | 3-pole terminal block | 3-pole terminal block | 3-pole terminal block | 3-pole terminal block | | 3-pole terminal block | 3-pole terminal block | 2 x 3-pole terminal block | 2 x 3-pole terminal block | design of the removable storage | | | | | | Yes | Yes | Yes | Yes | Signal-Inputs/outputs | | | | | Operating voltage of the signaling contacts | | | | | | 276V | 276V | 276V | 276V | | 230V | 230V | 230V | 230V | Operating current of the signaling contacts | | | | | | 5A | 5A | 5A | 5A | | 0.1A | 0.1A | 0.1A | 0.1A | Supply voltage, current consumption, power loss | | | | | Type of voltage supply redundant power supply unit | No | No | Yes | Yes | Type of voltage of the supply voltage | AC | AC | AC | AC | Supply voltage | | | | | | 230V | 230V | 230V | 230V | | 80...276V | 80...276V | 80...276V | 80...276V | Supply voltage 2 Rated value | | | | | | DC | DC | DC | DC | Supply voltage at DC | 220V | 220V | 220V | 220V | | 46.25...300V | 46.25...300V | 46.25...300V | 46.25...300V | Product component fusing at power supply input | Yes | Yes | Yes | Yes | Fuse protection type at input for supply voltage | T 2 A / 250 V | T 2 A / 250 V | T 2 A / 250 V | T 2 A / 250 V | Consumed current maximum | 0.08A | 0.08A | 0.08A | 0.08A | Power loss [W] | | | | | | 18W | 18W | 18W | 18W | | 18W | 18W | 18W | 18W | Permitted ambient conditions | | | | | Ambient temperature | | | | | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | -40...+70C | -40...+70C | -40...+70C | -40...+70C | | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | A maximum operating temperature of +85 C is permissible for a duration of 16 hours | Relative humidity | | | | | | 95% | 95% | 95% | 95% | Protection class IP | IP30 | IP30 | IP30 | IP30 | Design, dimensions and weight | | | | | Design | compact | compact | compact | compact | Width | 216mm | 216mm | 216mm | 216mm | Height | 143mm | 143mm | 143mm | 143mm | Depth | 110mm | 110mm | 110mm | 110mm | Net weight | 1.85kg | 1.85kg | 2.12kg | 2.12kg | Product feature conformal coating | No | Yes | No | Yes | Mounting type | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | Product properties, functions, components general | | | | | Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s | 100 | 100 | 100 | 100 | Cascading in cases of star topology | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | any (depending only on signal propagation time) | Product functions management, configuration | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Identification & maintenance function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Diagnosis | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions VLAN | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | | Yes | Yes | Yes | Yes | Number of VLANs maximum | 255 | 255 | 255 | 255 | Number of VLANs - dynamic maximum | 255 | 255 | 255 | 255 | Protocol is supported GVRP | Yes | Yes | Yes | Yes | Product functions DHCP | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Redundancy | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported Media Redundancy Protocol (MRP) | Yes | Yes | Yes | Yes | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Product functions Security | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | Product functions Time | | | | | Product function | | | | | | Yes | Yes | Yes | Yes | Protocol is supported | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals | | | | | Standard | | | | | | - | - | - | - | | UL 508, CSA C22.2 No. 142-M1987 | UL 508, CSA C22.2 No. 142-M1987 | UL 508, CSA C22.2 No. 142-M1987 | UL 508, CSA C22.2 No. 142-M1987 | | - | - | - | - | | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | EN 61000-6-4:2007 (Class A) | | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | EN 61000-6-2:2005 | Standards, specifications, approvals CE | | | | | Certificate of suitability CE marking | Yes | Yes | Yes | Yes | Standard | | | | | | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | IEC 61850, IEEE 1613 | Standards, specifications, approvals miscellaneous | | | | | Certificate of suitability | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | EN 61000-6-2:2005, EN 61000-6-4:2007 | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | Standards, specifications, approvals ship classification | | | | | Marine classification association | | | | | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | Yes | Yes | Yes | Yes | | Yes | Yes | Yes | Yes | | No | No | No | No | | No | No | No | No | Standards, specifications, approvals product conformity | | | | | MTBF at 40 C | 24.6y | 24.6y | 16.1y | 16.1y |
|
|