SCALANCE X-300EEC managed

Order number

6GK5302-7GD00-1EA3

6GK5302-7GD00-1GA3

6GK5302-7GD00-2EA3

6GK5302-7GD00-2GA3

Product type designation

SCALANCE X302-7EEC

SCALANCE X302-7EEC

SCALANCE X302-7EEC

SCALANCE X302-7EEC

Transmission rate

 

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

Interfaces

 

 

 

 

Number of electrical/optical connections

 

 

 

 

  • ? for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

 

 

 

 

  • ? for network components or terminal equipment

2

2

2

2

Type of electrical connection

 

 

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

Number of optical interfaces

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

7

7

7

7

Design of the optical interface

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

Connectable optical power relative to 1 mW

 

 

 

 

  • ? of the transmitter output

-19 ... -14

-19 ... -14

-19 ... -14

-19 ... -14

  • ? of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Damping ratio of the FOC transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 ... 5 km

0 ... 5 km

0 ... 5 km

0 ... 5 km

Interfaces for communication integrated

 

 

 

 

Number of 100 Mbit/s SC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Number of 1000 Mbit/s LC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Interfaces others

 

 

 

 

Number of electrical connections

 

 

 

 

  • ? for signaling contact

1

1

2

2

  • ? for power supply

1

1

2

2

  • ? for redundant voltage supply

1

1

2

2

Type of electrical connection

 

 

 

 

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

4-pole terminal block

4-pole terminal block

2 x 4-pole terminal block

2 x 4-pole terminal block

design of the removable storage

 

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

 

Operating voltage of the signaling contacts

 

 

 

 

  • ? for DC Rated value

24 V

24 V

24 V

24 V

Operating current of the signaling contacts

 

 

 

 

  • ? for DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of voltage supply redundant power supply unit

No

No

Yes

Yes

Type of voltage of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • ? external

24 V

24 V

24 V

24 V

  • ? external

19.2 ... 57.6 V

19.2 ... 57.6 V

19.2 ... 57.6 V

19.2 ... 57.6 V

Supply voltage 2 Rated value

  • ? Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • ? for DC

24 V

24 V

24 V

24 V

  • ? for DC Rated value minimum

19.2 V

19.2 V

19.2 V

19.2 V

  • ? for DC Rated value maximum

57.6 V

57.6 V

57.6 V

57.6 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Fuse protection type at input for supply voltage

T 4 A / 125 V

T 4 A / 125 V

T 4 A / 125 V

T 4 A / 125 V

Consumed current maximum

0.75 A

0.75 A

0.75 A

0.75 A

Active power loss

 

 

 

 

  • ? for DC at 24 V

17 W

17 W

17 W

17 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? Note

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity

 

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Ambient condition

 

 

 

 

  • ? for operation

Conformal coating, no

Conformal coating, yes

Conformal coating, no

Conformal coating, yes

Coating

Conformal Coating, no

Conformal Coating, yes

Conformal Coating, no

Conformal Coating, yes

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

compact

compact

compact

compact

Width

216 mm

216 mm

216 mm

216 mm

Height

143 mm

143 mm

143 mm

143 mm

Depth

110 mm

110 mm

110 mm

110 mm

Net weight

1.8 kg

1.8 kg

2.03 kg

1.8 kg

Mounting type

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

  • ? 19-inch installation

Yes

Yes

Yes

Yes

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

Yes

Yes

  • ? S7-1500 rail mounting

No

No

No

No

Product properties, functions, components general

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

100

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

 

Product function

 

 

 

 

  • ? CLI

Yes

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

Yes

  • ? RMON

Yes

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

Yes

  • ? multiport mirroring

Yes

Yes

Yes

Yes

  • ? CoS

Yes

Yes

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? Telnet

Yes

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

Yes

  • ? BOOTP

Yes

Yes

Yes

Yes

  • ? GMRP

Yes

Yes

Yes

Yes

  • ? DCP

Yes

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

 

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

 

Product function

 

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

Yes

  • ? SysLog

Yes

Yes

Yes

Yes

Product functions VLAN

 

 

 

 

Product function

 

 

 

 

  • ? VLAN - port based

Yes

Yes

Yes

Yes

  • ? VLAN - protocol-based

No

No

No

No

  • ? VLAN - IP-based

No

No

No

No

  • ? VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functions DHCP

 

 

 

 

Product function

 

 

 

 

  • ? DHCP client

Yes

Yes

Yes

Yes

  • ? DHCP Option 82

Yes

Yes

Yes

Yes

  • ? DHCP Option 66

Yes

Yes

Yes

Yes

  • ? DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

 

 

 

 

Product function

 

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

 

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • ? Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? STP/RSTP

Yes

Yes

Yes

Yes

  • ? STP

Yes

Yes

Yes

Yes

  • ? RSTP

Yes

Yes

Yes

Yes

  • ? MSTP

No

No

No

No

  • ? RSTP big network support

Yes

Yes

Yes

Yes

  • ? LACP

Yes

Yes

Yes

Yes

Product functions Security

 

 

 

 

Product function

 

 

 

 

  • ? ACL - MAC-based

Yes

Yes

Yes

Yes

  • ? ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SSH

Yes

Yes

Yes

Yes

Product functions Time

 

 

 

 

Product function

 

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? NTP

Yes

Yes

Yes

Yes

  • ? SNTP

Yes

Yes

Yes

Yes

  • ? IEEE 1588 profile default

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • ? for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

  • ? for safety from CSA and UL

UL 508

UL 508

UL 508

UL 508

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

No

No

  • ? IEC 61850-3

Yes

Yes

Yes

Yes

  • ? IEEE 1613

Yes

Yes

Yes

Yes

MTBF at 40 °C

27.2 y

27.2 y

19.6 y

19.6 y


Order number

6GK5302-7GD00-3EA3

6GK5302-7GD00-3GA3

6GK5302-7GD00-4EA3

6GK5302-7GD00-4GA3

Product type designation

SCALANCE X302-7EEC

SCALANCE X302-7EEC

SCALANCE X302-7EEC

SCALANCE X302-7EEC

Transmission rate

 

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

Interfaces

 

 

 

 

Number of electrical/optical connections

 

 

 

 

  • ? for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

 

 

 

 

  • ? for network components or terminal equipment

2

2

2

2

Type of electrical connection

 

 

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

Number of optical interfaces

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

7

7

7

7

Design of the optical interface

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

Connectable optical power relative to 1 mW

 

 

 

 

  • ? of the transmitter output

-19 ... -14

-19 ... -14

-19 ... -14

-19 ... -14

  • ? of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Damping ratio of the FOC transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 ... 5 km

0 ... 5 km

0 ... 5 km

0 ... 5 km

Interfaces for communication integrated

 

 

 

 

Number of 100 Mbit/s SC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Number of 1000 Mbit/s LC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Interfaces others

 

 

 

 

Number of electrical connections

 

 

 

 

  • ? for signaling contact

1

1

2

2

  • ? for power supply

1

1

1

1

  • ? for redundant voltage supply

1

1

Type of electrical connection

 

 

 

 

  • ? for signaling contact

3-pole terminal block

3-pole terminal block

3-pole terminal block

3-pole terminal block

  • ? for power supply

3-pole terminal block

3-pole terminal block

2 x 3-pole terminal block

2 x 3-pole terminal block

design of the removable storage

 

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

 

Operating voltage of the signaling contacts

 

 

 

 

  • ? with AC Rated value

276 V

276 V

276 V

276 V

  • ? for DC Rated value

230 V

230 V

230 V

230 V

Operating current of the signaling contacts

 

 

 

 

  • ? with AC maximum

5 A

5 A

5 A

5 A

  • ? for DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of voltage supply redundant power supply unit

No

No

Yes

Yes

Type of voltage of the supply voltage

AC

AC

AC

AC

Supply voltage

 

 

 

 

  • ? with AC

230 V

230 V

230 V

230 V

  • ? with AC Rated value

80 ... 276 V

80 ... 276 V

80 ... 276 V

80 ... 276 V

Supply voltage 2 Rated value

  • ? Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • ? for DC

220 V

220 V

220 V

220 V

  • ? for DC Rated value minimum

46.25 V

46.25 V

46.25 V

46.25 V

  • ? for DC Rated value maximum

300 V

300 V

300 V

300 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Fuse protection type at input for supply voltage

T 2 A / 250 V

T 2 A / 250 V

T 2 A / 250 V

T 2 A / 250 V

Consumed current maximum

0.08 A

0.08 A

0.08 A

0.08 A

Active power loss

 

 

 

 

  • ? with AC at 230 V

18 W

18 W

18 W

18 W

  • ? for DC at 250 V

18 W

18 W

18 W

18 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? Note

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity

 

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Ambient condition

 

 

 

 

  • ? for operation

Conformal coating, no

Conformal coating, yes

Conformal coating, no

Conformal coating, yes

Coating

Conformal Coating, no

Conformal Coating, yes

Conformal Coating, no

Conformal Coating, yes

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

compact

compact

compact

compact

Width

216 mm

216 mm

216 mm

216 mm

Height

143 mm

143 mm

143 mm

143 mm

Depth

110 mm

110 mm

110 mm

110 mm

Net weight

1.85 kg

1.85 kg

2.12 kg

2.12 kg

Mounting type

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

  • ? 19-inch installation

Yes

Yes

Yes

Yes

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

Yes

Yes

  • ? S7-1500 rail mounting

No

No

No

No

Product properties, functions, components general

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

100

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

 

Product function

 

 

 

 

  • ? CLI

Yes

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

Yes

  • ? RMON

Yes

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

Yes

  • ? multiport mirroring

Yes

Yes

Yes

Yes

  • ? CoS

Yes

Yes

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? Telnet

Yes

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

Yes

  • ? BOOTP

Yes

Yes

Yes

Yes

  • ? GMRP

Yes

Yes

Yes

Yes

  • ? DCP

Yes

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

 

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

 

Product function

 

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

Yes

  • ? SysLog

Yes

Yes

Yes

Yes

Product functions VLAN

 

 

 

 

Product function

 

 

 

 

  • ? VLAN - port based

Yes

Yes

Yes

Yes

  • ? VLAN - protocol-based

No

No

No

No

  • ? VLAN - IP-based

No

No

No

No

  • ? VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functions DHCP

 

 

 

 

Product function

 

 

 

 

  • ? DHCP client

Yes

Yes

Yes

Yes

  • ? DHCP Option 82

Yes

Yes

Yes

Yes

  • ? DHCP Option 66

Yes

Yes

Yes

Yes

  • ? DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

 

 

 

 

Product function

 

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

 

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • ? Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? STP/RSTP

Yes

Yes

Yes

Yes

  • ? STP

Yes

Yes

Yes

Yes

  • ? RSTP

Yes

Yes

Yes

Yes

  • ? MSTP

No

No

No

No

  • ? RSTP big network support

Yes

Yes

Yes

Yes

  • ? LACP

Yes

Yes

Yes

Yes

Product functions Security

 

 

 

 

Product function

 

 

 

 

  • ? ACL - MAC-based

Yes

Yes

Yes

Yes

  • ? ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SSH

Yes

Yes

Yes

Yes

Product functions Time

 

 

 

 

Product function

 

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? NTP

Yes

Yes

Yes

Yes

  • ? SNTP

Yes

Yes

Yes

Yes

  • ? IEEE 1588 profile default

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • ? for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • ? for FM

-

-

-

-

  • ? for hazardous zone

-

-

-

-

  • ? for safety from CSA and UL

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

  • ? for hazardous zone from CSA and UL

-

-

-

-

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

No

No

  • ? IEC 61850-3

Yes

Yes

Yes

Yes

  • ? IEEE 1613

Yes

Yes

Yes

Yes

MTBF at 40 °C

22.8 y

22.8 y

15.3 y

15.3 y


Order number

6GK5307-2FD00-1EA3

6GK5307-2FD00-1GA3

6GK5307-2FD00-2EA3

6GK5307-2FD00-2GA3

Product type designation

SCALANCE X307-2EEC

SCALANCE X307-2EEC

SCALANCE X307-2EEC

SCALANCE X307-2EEC

Transmission rate

 

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

Interfaces

 

 

 

 

Number of electrical/optical connections

 

 

 

 

  • ? for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

 

 

 

 

  • ? for network components or terminal equipment

7

7

7

7

Type of electrical connection

 

 

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

Number of optical interfaces

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

2

2

2

2

Design of the optical interface

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

Connectable optical power relative to 1 mW

 

 

 

 

  • ? of the transmitter output

-19 ... -14

-19 ... -14

-19 ... -14

-19 ... -14

  • ? of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Damping ratio of the FOC transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 ... 5 km

0 ... 5 km

0 ... 5 km

0 ... 5 km

Interfaces for communication integrated

 

 

 

 

Number of 100 Mbit/s SC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Number of 1000 Mbit/s LC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Interfaces others

 

 

 

 

Number of electrical connections

 

 

 

 

  • ? for signaling contact

1

1

2

2

  • ? for power supply

1

1

2

2

  • ? for redundant voltage supply

1

1

2

2

Type of electrical connection

 

 

 

 

  • ? for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • ? for power supply

4-pole terminal block

4-pole terminal block

2 x 4-pole terminal block

2 x 4-pole terminal block

design of the removable storage

 

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

 

Operating voltage of the signaling contacts

 

 

 

 

  • ? for DC Rated value

24 V

24 V

24 V

24 V

Operating current of the signaling contacts

 

 

 

 

  • ? for DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of voltage supply redundant power supply unit

No

No

Yes

Yes

Type of voltage of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • ? external

24 V

24 V

24 V

24 V

  • ? external

19.2 ... 57.6 V

19.2 ... 57.6 V

19.2 ... 57.6 V

19.2 ... 57.6 V

Supply voltage 2 Rated value

  • ? Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • ? for DC

24 V

24 V

24 V

24 V

  • ? for DC Rated value minimum

19.2 V

19.2 V

19.2 V

19.2 V

  • ? for DC Rated value maximum

57.6 V

57.6 V

57.6 V

57.6 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Fuse protection type at input for supply voltage

T 4 A / 125 V

T 4 A / 125 V

T 4 A / 125 V

T 4 A / 125 V

Consumed current maximum

0.75 A

0.75 A

0.75 A

0.75 A

Active power loss

 

 

 

 

  • ? for DC at 24 V

12 W

12 W

12 W

12 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? Note

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity

 

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Ambient condition

 

 

 

 

  • ? for operation

Conformal coating, no

Conformal coating, yes

Conformal coating, no

Conformal coating, yes

Coating

Conformal Coating, no

Conformal Coating, yes

Conformal Coating, no

Conformal Coating, yes

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

compact

compact

compact

compact

Width

216 mm

216 mm

216 mm

216 mm

Height

143 mm

143 mm

143 mm

143 mm

Depth

110 mm

110 mm

110 mm

110 mm

Net weight

1.8 kg

1.8 kg

2.03 kg

2.03 kg

Mounting type

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

  • ? 19-inch installation

Yes

Yes

Yes

Yes

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

Yes

Yes

  • ? S7-1500 rail mounting

No

No

No

No

Product properties, functions, components general

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

100

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

 

Product function

 

 

 

 

  • ? CLI

Yes

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

Yes

  • ? RMON

Yes

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

Yes

  • ? multiport mirroring

Yes

Yes

Yes

Yes

  • ? CoS

Yes

Yes

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? Telnet

Yes

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

Yes

  • ? BOOTP

Yes

Yes

Yes

Yes

  • ? GMRP

Yes

Yes

Yes

Yes

  • ? DCP

Yes

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

 

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

 

Product function

 

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

Yes

  • ? SysLog

Yes

Yes

Yes

Yes

Product functions VLAN

 

 

 

 

Product function

 

 

 

 

  • ? VLAN - port based

Yes

Yes

Yes

Yes

  • ? VLAN - protocol-based

No

No

No

No

  • ? VLAN - IP-based

No

No

No

No

  • ? VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functions DHCP

 

 

 

 

Product function

 

 

 

 

  • ? DHCP client

Yes

Yes

Yes

Yes

  • ? DHCP Option 82

Yes

Yes

Yes

Yes

  • ? DHCP Option 66

Yes

Yes

Yes

Yes

  • ? DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

 

 

 

 

Product function

 

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

 

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • ? Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? STP/RSTP

Yes

Yes

Yes

Yes

  • ? STP

Yes

Yes

Yes

Yes

  • ? RSTP

Yes

Yes

Yes

Yes

  • ? MSTP

No

No

No

No

  • ? RSTP big network support

Yes

Yes

Yes

Yes

  • ? LACP

Yes

Yes

Yes

Yes

Product functions Security

 

 

 

 

Product function

 

 

 

 

  • ? ACL - MAC-based

Yes

Yes

Yes

Yes

  • ? ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SSH

Yes

Yes

Yes

Yes

Product functions Time

 

 

 

 

Product function

 

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? NTP

Yes

Yes

Yes

Yes

  • ? SNTP

Yes

Yes

Yes

Yes

  • ? IEEE 1588 profile default

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • ? for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • ? for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • ? for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4

  • ? for safety from CSA and UL

UL 508

UL 508

UL 508

UL 508

  • ? for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, UL 1604 and 2279-15, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

No

No

  • ? IEC 61850-3

Yes

Yes

Yes

Yes

  • ? IEEE 1613

Yes

Yes

Yes

Yes

MTBF at 40 °C

29.9 y

29.9 y

20.9 y

20.9 y


Order number

6GK5307-2FD00-3EA3

6GK5307-2FD00-3GA3

6GK5307-2FD00-4EA3

6GK5307-2FD00-4GA3

Product type designation

SCALANCE X307-2EEC

SCALANCE X307-2EEC

SCALANCE X307-2EEC

SCALANCE X307-2EEC

Transmission rate

 

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

Interfaces

 

 

 

 

Number of electrical/optical connections

 

 

 

 

  • ? for network components or terminal equipment maximum

9

9

9

9

Number of electrical connections

 

 

 

 

  • ? for network components or terminal equipment

7

7

7

7

Type of electrical connection

 

 

 

 

  • ? for network components or terminal equipment

RJ45 port

RJ45 port

RJ45 port

RJ45 port

Number of optical interfaces

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

2

2

2

2

Design of the optical interface

 

 

 

 

  • ? for fiber optic cable at 100 Mbit/s

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

LC port (multimode up to 5 km)

Connectable optical power relative to 1 mW

 

 

 

 

  • ? of the transmitter output

-19 ... -14

-19 ... -14

-19 ... -14

-19 ... -14

  • ? of the receiver input maximum

-14 dB

-14 dB

-14 dB

-14 dB

Optical sensitivity relating to 1 mW of the receiver input minimum

-32 dB

-32 dB

-32 dB

-32 dB

Damping ratio of the FOC transmission link minimum necessary

0 dB

0 dB

0 dB

0 dB

Range at the optical interface depending on the optical fiber used

0 ... 5 km

0 ... 5 km

0 ... 5 km

0 ... 5 km

Interfaces for communication integrated

 

 

 

 

Number of 100 Mbit/s SC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Number of 1000 Mbit/s LC ports

 

 

 

 

  • ? for multimode

0

0

0

0

Interfaces others

 

 

 

 

Number of electrical connections

 

 

 

 

  • ? for signaling contact

1

1

2

2

  • ? for power supply

1

1

1

1

  • ? for redundant voltage supply

1

1

Type of electrical connection

 

 

 

 

  • ? for signaling contact

3-pole terminal block

3-pole terminal block

3-pole terminal block

3-pole terminal block

  • ? for power supply

3-pole terminal block

3-pole terminal block

2 x 3-pole terminal block

2 x 3-pole terminal block

design of the removable storage

 

 

 

 

  • ? C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

 

Operating voltage of the signaling contacts

 

 

 

 

  • ? with AC Rated value

276 V

276 V

276 V

276 V

  • ? for DC Rated value

230 V

230 V

230 V

230 V

Operating current of the signaling contacts

 

 

 

 

  • ? with AC maximum

5 A

5 A

5 A

5 A

  • ? for DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of voltage supply redundant power supply unit

No

No

Yes

Yes

Type of voltage of the supply voltage

AC

AC

AC

AC

Supply voltage

 

 

 

 

  • ? with AC

230 V

230 V

230 V

230 V

  • ? with AC Rated value

80 ... 276 V

80 ... 276 V

80 ... 276 V

80 ... 276 V

Supply voltage 2 Rated value

  • ? Type of voltage 2 of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • ? for DC

220 V

220 V

220 V

220 V

  • ? for DC Rated value minimum

46.25 V

46.25 V

46.25 V

46.25 V

  • ? for DC Rated value maximum

300 V

300 V

300 V

300 V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Fuse protection type at input for supply voltage

T 2 A / 250 V

T 2 A / 250 V

T 2 A / 250 V

T 2 A / 250 V

Consumed current maximum

0.08 A

0.08 A

0.08 A

0.08 A

Active power loss

 

 

 

 

  • ? with AC at 230 V

18 W

18 W

18 W

18 W

  • ? for DC at 250 V

18 W

18 W

18 W

18 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • ? during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • ? Note

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

A maximum operating temperature of +85 °C is permissible for a duration of 16 hours

Relative humidity

 

 

 

 

  • ? at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Ambient condition

 

 

 

 

  • ? for operation

Conformal coating, no

Conformal coating, yes

Conformal coating, no

Conformal coating, yes

Coating

Conformal Coating, no

Conformal Coating, yes

Conformal Coating, no

Conformal Coating, yes

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

 

 

 

 

Design

compact

compact

compact

compact

Width

216 mm

216 mm

216 mm

216 mm

Height

143 mm

143 mm

143 mm

143 mm

Depth

110 mm

110 mm

110 mm

110 mm

Net weight

1.85 kg

1.85 kg

2.12 kg

2.12 kg

Mounting type

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

Wall mounting is possible only with an additional wall bracket; 19" mounting only with installation of two X-300EEC switches in pairs using a mounting plate

  • ? 19-inch installation

Yes

Yes

Yes

Yes

  • ? 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • ? wall mounting

Yes

Yes

Yes

Yes

  • ? S7-300 rail mounting

Yes

Yes

Yes

Yes

  • ? S7-1500 rail mounting

No

No

No

No

Product properties, functions, components general

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

100

Cascading in cases of star topology

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

 

Product function

 

 

 

 

  • ? CLI

Yes

Yes

Yes

Yes

  • ? web-based management

Yes

Yes

Yes

Yes

  • ? MIB support

Yes

Yes

Yes

Yes

  • ? TRAPs via email

Yes

Yes

Yes

Yes

  • ? Configuration with STEP 7

Yes

Yes

Yes

Yes

  • ? RMON

Yes

Yes

Yes

Yes

  • ? Port mirroring

Yes

Yes

Yes

Yes

  • ? multiport mirroring

Yes

Yes

Yes

Yes

  • ? CoS

Yes

Yes

Yes

Yes

  • ? with IRT PROFINET IO switch

No

No

No

No

  • ? PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • ? switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? Telnet

Yes

Yes

Yes

Yes

  • ? HTTP

Yes

Yes

Yes

Yes

  • ? HTTPS

Yes

Yes

Yes

Yes

  • ? TFTP

Yes

Yes

Yes

Yes

  • ? FTP

Yes

Yes

Yes

Yes

  • ? BOOTP

Yes

Yes

Yes

Yes

  • ? GMRP

Yes

Yes

Yes

Yes

  • ? DCP

Yes

Yes

Yes

Yes

  • ? LLDP

Yes

Yes

Yes

Yes

  • ? IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

 

 

 

 

  • ? I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • ? I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SNMP v1

Yes

Yes

Yes

Yes

  • ? SNMP v2

Yes

Yes

Yes

Yes

  • ? SNMP v3

Yes

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

 

Product function

 

 

 

 

  • ? Port diagnostics

Yes

Yes

Yes

Yes

  • ? Statistics Packet Size

Yes

Yes

Yes

Yes

  • ? Statistics packet type

Yes

Yes

Yes

Yes

  • ? Error statistics

Yes

Yes

Yes

Yes

  • ? SysLog

Yes

Yes

Yes

Yes

Product functions VLAN

 

 

 

 

Product function

 

 

 

 

  • ? VLAN - port based

Yes

Yes

Yes

Yes

  • ? VLAN - protocol-based

No

No

No

No

  • ? VLAN - IP-based

No

No

No

No

  • ? VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functions DHCP

 

 

 

 

Product function

 

 

 

 

  • ? DHCP client

Yes

Yes

Yes

Yes

  • ? DHCP Option 82

Yes

Yes

Yes

Yes

  • ? DHCP Option 66

Yes

Yes

Yes

Yes

  • ? DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

 

 

 

 

Product function

 

 

 

 

  • ? Ring redundancy

Yes

Yes

Yes

Yes

  • ? High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

 

 

 

 

  • ? media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • ? redundancy procedure STP

Yes

Yes

Yes

Yes

  • ? redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • ? redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • ? Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? STP/RSTP

Yes

Yes

Yes

Yes

  • ? STP

Yes

Yes

Yes

Yes

  • ? RSTP

Yes

Yes

Yes

Yes

  • ? MSTP

No

No

No

No

  • ? RSTP big network support

Yes

Yes

Yes

Yes

  • ? LACP

Yes

Yes

Yes

Yes

Product functions Security

 

 

 

 

Product function

 

 

 

 

  • ? ACL - MAC-based

Yes

Yes

Yes

Yes

  • ? ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • ? IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • ? Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • ? broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? SSH

Yes

Yes

Yes

Yes

Product functions Time

 

 

 

 

Product function

 

 

 

 

  • ? SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • ? NTP

Yes

Yes

Yes

Yes

  • ? SNTP

Yes

Yes

Yes

Yes

  • ? IEEE 1588 profile default

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • ? for EMC

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

IEC 61850, IEEE 1613

  • ? for FM

-

-

-

-

  • ? for hazardous zone

-

-

-

-

  • ? for safety from CSA and UL

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

UL 508, CSA C22.2 No. 142-M1987

  • ? for hazardous zone from CSA and UL

-

-

-

-

  • ? for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • ? for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • ? CE marking

Yes

Yes

Yes

Yes

  • ? C-Tick

Yes

Yes

Yes

Yes

  • ? KC approval

Yes

Yes

Yes

Yes

  • ? Railway application in accordance with EN 50155

No

No

No

No

  • ? Railway application in accordance with EN 50124-1

No

No

No

No

  • ? IEC 61850-3

Yes

Yes

Yes

Yes

  • ? IEEE 1613

Yes

Yes

Yes

Yes

MTBF at 40 °C

24.6 y

24.6 y

16.1 y

16.1 y


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2016
Каталог продуктов Siemens Industry Приводная техника Техника автоматизации Системы автоматизации Системы визуализации SIMATIC HMI Системы идентификации Промышленные коммуникации SIMATIC NET Введение Industrial Ethernet PROFINET Введение Привода Контроллеры Система управления процессами SIMATIC PCS 7 Распределенная периферия Система управления перемещениями SIMOTION Системы ЧПУ SINUMERIK Устройства отображения и контроля Активные сетевые компоненты Промышленные ПК Коммутационные и защитные приборы для распределения энергии Обзор системы Измерительные приборы SENTRON Конфигурирование, визуализация и управление с SIMATIC Конфигурирование, визуализация и управление с SENTRON Производственные датчики Пассивные сетевые компоненты Сетевые компоненты для Industrial Ethernet Industrial Ethernet коммутаторы Компактные коммутаторы CSM Неуправляемые коммутаторы SCALANCE X-000 Неуправляемые коммутаторы/конверторы SCALANCE X-100 Управляемые коммутаторы SCALANCE X-200 Управляемые коммутаторы SCALANCE X-200IRT Управляемые коммутаторы SCALANCE X-300 Управляемые коммутаторы SCALANCE X-300 Коммутаторы SIPLUS SCALANCE X-300 Управляемые коммутаторы SCALANCE XR-300 Управляемый коммутатор SCALANCE X-300PoE Управляемый коммутатор SCALANCE XR-300PoE Управляемые коммутаторы SCALANCE X-300EEC Управляемые коммутаторы SCALANCE XR-300EEC Конвертирующие модули для SCALANCE X-300 Управляемые коммутаторы (Уровень 3) SCALANCE X-400 Управляемые коммутаторы (уровень 3) SCALANCE X-500 Безопасность передачи данных в промышленных сетях Промышленные беспроводные коммуникации Промышленная мобильная коммуникация Маршрутизаторы Аппаратура управления Блоки питания SITOP Датчики Инжиниринговые пакеты Engineering / Network management / Diagnostics Технологические компоненты PROFINET Системный интерфейс к SIMATIC HMI PROFIBUS AS-интерфейс IO-Link Промышленная беспроводная связь SINAUT ST7 Информационная безопасность в промышленности Сетевые переходы ECOFAST Промышленные аппараты управления SIRIUS Промышленные информационные технологии Управление на базе РС Системы управления процессом Датчики Блоки питания Продукты для специальных требований Автоматизация и безопасность зданий Низковольтная коммутационная техника Технология безопасности Системные решения и продукты для отраслей Сервис ... и все, что Вам еще необходимо




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика