Aluminum series 1LE1, frame sizes 100 to 160 – self-ventilated motors with increased output and improved/high efficiency
Type of construction IM B3
Types of construction IM B5 and IM V1
For flange dimensions, see "Flange dimensions" (Z = the number of retaining holes)
Type of construction IM B35
For flange dimensions, see "Flange dimensions" (Z = the number of retaining holes)
Type of construction IM B14
For flange dimensions, see "Flange dimensions" (Z = the number of retaining holes)
For motor |
Dimension designation acc. toIEC | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Frame size |
Number of poles |
A |
AA |
AB |
AC |
AD |
AD' |
AF |
AF' |
AG |
AQ |
AS |
B* |
BA |
BA' |
BB |
BC |
BE |
BE' |
C |
CA* |
H |
HA |
Y1) |
100 L |
2, 4, 6, 8 |
160 |
42 |
196 |
198 |
166 |
166 |
125.5 |
125.5 |
135 |
195 |
63.5 |
140 |
37.5 |
– |
176 |
33.5 |
50 |
25 |
63 |
176.2 |
100 |
12 |
45 |
112 M |
2, 4, 6, 8 |
190 |
46 |
226 |
222 |
177 |
177 |
136.5 |
136.5 |
135 |
195 |
63.5 |
140 |
35.4 |
– |
176 |
26 |
50 |
25 |
70 |
155 |
112 |
12 |
52 |
132 M |
2, 4, 6, 8 |
216 |
53 |
256 |
262 |
202 |
202 |
159.5 |
159.5 |
155 |
260 |
70.5 |
178 |
38 |
– |
218 |
26.5 |
48 |
24 |
89 |
178.5 |
132 |
15 |
69 |
160 L |
2, 4, 6, 8 |
254 |
60 |
300 |
314 |
236.5 |
236.5 |
190 |
190 |
175 |
260 |
77.5 |
254 |
44 |
– |
300 |
47 |
57 |
28.5 |
108 |
208 |
160 |
18 |
85 |
* This dimension is assigned in DIN EN 50347 to the frame size listed.
1)Additional information: not a standard dimension acc. to DIN 50347.
For motor |
Dimension designation acc. toIEC |
DE shaft extension |
NDE shaft extension | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Frame size |
Number of poles |
HH |
K |
K’ |
L 1) |
L1 |
D1 |
LC |
LL |
LM |
D |
DB |
E |
EB |
ED |
F |
GA |
DA |
DC |
EA |
EC |
EE |
FA |
GC |
100 L |
2, 4, 6, 8 |
96.5 |
12 |
16 |
430.5 |
7 |
32 |
489.2 |
112 |
463.5 |
28 |
M10 |
60 |
50 |
5 |
8 |
31 |
24 |
M8 |
50 |
40 |
5 |
8 |
27 |
112 M |
2, 4, 6, 8 |
96 |
12 |
16 |
414 |
7 |
32 |
475 |
112 |
447 |
28 |
M10 |
60 |
50 |
5 |
8 |
31 |
24 |
M8 |
50 |
40 |
5 |
8 |
27 |
132 M |
2, 4, 6, 8 |
115.5 |
12 |
16 |
515 |
8.5 |
39 |
585.5 |
130 |
550.5 |
38 |
M12 |
80 |
70 |
5 |
10 |
41 |
28 |
M10 |
60 |
50 |
5 |
8 |
31 |
160 L |
2, 4, 6, 8 |
155 |
15 |
19 |
664 |
10 |
45 |
790 |
145 |
698 |
42 |
M16 |
110 |
90 |
10 |
12 |
45 |
42 |
M16 |
110 |
90 |
10 |
12 |
45 |
1) The length is specified as far as the tip of the fan cover.