In DIN EN 50347, the frame sizes are allocated flange FF with through holes and flange FT with tapped holes. The designation of flange A and C according to DIN 42948 (invalid since 09/2003) are also listed for information purposes. See the table below.
(Z = the number of retaining holes)
Frame size |
Type of construction |
Flange type |
Flange with |
Dimension designation acc. to IEC | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
According to DIN EN 50347 |
Acc. to DIN 42948 |
LA |
LE |
M |
N |
P |
S |
T |
Z | |||
63 M |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 115 |
A 140 |
8 |
23 |
115 |
95 |
140 |
10 |
3 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 75 |
C 90 |
– |
23 |
75 |
60 |
90 |
M5 |
2.5 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 100 |
C 120 |
– |
23 |
100 |
80 |
120 |
M6 |
3 |
4 | |
71 M |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 130 |
A 160 |
9 |
30 |
130 |
110 |
160 |
10 |
3.5 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 85 |
C 105 |
– |
30 |
85 |
70 |
105 |
M6 |
2.5 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 115 |
C 140 |
– |
30 |
115 |
95 |
140 |
M8 |
3 |
4 | |
80 M |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 165 |
A 200 |
10 |
40 |
165 |
130 |
200 |
12 |
3.5 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 100 |
C 120 |
– |
40 |
100 |
80 |
120 |
M6 |
3 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 130 |
C 160 |
– |
40 |
130 |
110 |
160 |
M8 |
3.5 |
4 | |
90 S, 90 L |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 165 |
A 200 |
10 |
50 |
165 |
130 |
200 |
12 |
3.5 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 115 |
C 140 |
– |
50 |
115 |
95 |
140 |
M8 |
3 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 130 |
C 160 |
– |
50 |
130 |
110 |
160 |
M8 |
3.5 |
4 | |
100 L |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 215 |
A 250 |
11 |
60 |
215 |
180 |
250 |
14.5 |
4 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 130 |
C 160 |
– |
60 |
130 |
110 |
160 |
M8 |
3.5 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 165 |
C 200 |
– |
60 |
165 |
130 |
200 |
M10 |
3.5 |
4 | |
112 M |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 215 |
A 250 |
11 |
60 |
215 |
180 |
250 |
14.5 |
4 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 130 |
C 160 |
– |
60 |
130 |
110 |
160 |
M8 |
3.5 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 165 |
C 200 |
– |
60 |
165 |
130 |
200 |
M10 |
3.5 |
4 | |
132 S, 132 M |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 265 |
A 300 |
12 |
80 |
265 |
230 |
300 |
14.5 |
4 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 165 |
C 200 |
– |
80 |
165 |
130 |
200 |
M10 |
3.5 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 215 |
C 250 |
– |
80 |
215 |
180 |
250 |
M12 |
4 |
4 | |
160 M, 160 L |
IM B5, IM B35, IM V1, IM V3 |
Flange |
FF 300 |
A 350 |
13 |
110 |
300 |
250 |
350 |
18.5 |
5 |
4 |
IM B14, IM B34, IM V18, IM V19 |
Standard flange |
FT 215 |
C 250 |
– |
110 |
215 |
180 |
250 |
M12 |
4 |
4 | |
IM B14, IM B34, IM V18, IM V19 |
Special flange |
FT 265 |
C 300 |
– |
110 |
265 |
230 |
300 |
M12 |
4 |
4 | |
180 M, 180 L |
IM B5, IM V1, IM V3 |
Flange |
FF 300 |
A 350 |
13 |
110 |
300 |
250 |
350 |
18.5 |
5 |
4 |
200 L |
IM B5 |
Flange |
FF 350 |
A 400 |
15 |
110 |
350 |
300 |
400 |
18.5 |
5 |
4 |
225 S, 225 M |
||||||||||||
2-pole |
IM B5, IM V1, IM V3 |
Flange |
FF 400 |
A 450 |
16 |
110 |
400 |
350 |
450 |
18.5 |
5 |
8 |
4- to 8-pole |
140 |
|||||||||||
250 M |
IM B5, IM V1, IM V3 |
Flange |
FF 500 |
A 550 |
18 |
140 |
500 |
450 |
550 |
18,5 |
5 |
8 |
280 S, 280 M |
IM B5, IM V1, IM V3 |
Flange |
FF 500 |
A 550 |
18 |
140 |
500 |
450 |
550 |
18.5 |
5 |
8 |
315 S, 315 M, |
||||||||||||
2-pole |
IM B5, IM V1, IM V3 |
Flange |
FF 600 |
A 660 |
22 |
140 |
600 |
550 |
660 |
24 |
6 |
8 |
4- to 8-pole |
170 |