Flow calculation and measurement- Dedicated volume flow calculation with DSP technology
- 100 Hz update rate for all output on all primary process values
- Maximum data age from sensor to output is 20 ms
- Independent low flow cut-off settings for volume and mass flow, standard volume flow and velocity
- Zero-point adjustment on command from discrete input or host system
Operation and display- User-configurable operation display
- Full graphical display 240 x 160 pixels with up to 6 programmable views
- Self-explaining alarm handling/log in clear text
- Help text for all parameters appears automatically in the configuration menu
- SensorFlash technology stores production specific system documentation and provides removable memory of all flowmeter setups and functions
- Calibration certificates (with ordered calibration)
- Non-volatile memory backup of operational data
- Transfer of user configuration to other flowmeters
- 4GB SD card for storage and data logging
- Audit trail of all parameter changes
- Alarm logging
Alarms and safety- Advanced diagnosis and service menu enhances troubleshooting and meter validation
- Configurable upper and lower alarm and warning limits for all process values
- Alarm handling can be selected between Siemens and NAMUR standard configurations
Outputs and control- Monitoring comprising of 3 individually configurable totalizers
- Multi-parameter outputs, configurable outputs assigned individually to any of the following parameters:
- Volume flow
- Standard volume flow
- Mass flow
- Flow velocity
- Sound velocity
- Density
- Process viscosity
- Process pressure
- Process/medium temperature
Up to six I/O channels are configured as follows. Channel 1Channel 1 is 4 to 20 mA analog output with HART 7.5. The current signal can be configured for massflow, volumeflow and includes the availability of active or passive function selected by wiring on the non-Ex terminals. Alternative Modbus RTU RS 485 is available. Channel 2Channel 2 is a signal output which can be freely configured for any process variable. - Analog current (0/4 to 20 mA)
- Frequency or pulse
- Operational and alarm status
Channels 3 and 4Channels 3 and 4 can be ordered with signal (freely configured for any process variable) or relay outputs, or signal input. Signal outputSignal output can be user configured to: - Analog current (0/4 to 20 mA)
- Frequency or pulse
- Redundant frequency or pulse (linked to channel 2)
- Operational and alarm status
Signal inputSignal input can be user-configured for: - Totalizer reset functions
- Force outputs or freeze process values
- Initiate automatic zero point adjustment
RelayRelay output(s) can be user configured to: 4-20 mA signal outputs and inputs are ordered as active or passive for Ex versions, active and passive for non-Ex versions - function selected by wiring on the terminals. During initial commissioning of the flowmeter, all outputs can be forced to a preset value for simulation, verification or calibration purposes. Channels 5 and 6- RTD temperature inputs for 1000, 500 or 100 О© RTD's -
2, 3 or 4 wire RTD's supported
Approvals and certificatesThe SITRANS FST030 transmitter was designed to comply with or exceed the requirements of international standards and regulations.
|