Siemens
01 2018
(4872) 700-366
skenergo@mail.ru
 01 2017  01 2016  

Article number

6BK1942-2AA00-0AA0

6BK1942-2CA00-0AA0

6BK1942-2CA00-0AA1

6BK1942-2DA00-0AA0

6BK1942-2FA00-0AA0

HCS POM4220 Lowend

HCS POM4220 Midrange

HCS POM4220 Midrange phase angle control

HCS POM4220 Highend

HCS POM4220 Flexible

General information

Product brand name

SIPLUS

Type of control of heat emitters

Half-wave control

Half-wave control and soft start

Half-wave control, phase control and soft start

Half-wave control

Installation type/mounting

Mounting type

Screw mounting to rack

Mounting position

vertical

Type of ventilation

Self ventilation or forced ventilation

Supply voltage

Type of supply voltage

AC

Rated value (AC)

230V

277V

Relative negative tolerance

10%

25%

Relative positive tolerance

10%

8%

2nd rated value (AC)

480V

110V

Relative negative tolerance

25%

10%

Relative positive tolerance

8%

15%

3rd rated value (AC)

70V

4th rated value (AC)

45V

Relative negative tolerance

10%

Relative positive tolerance

15%

Line frequency

  • Rated value 1

50Hz

  • Rated value 2

60Hz

  • Relative symmetrical tolerance

5%

Mains buffering

  • Recovery time after power failure, typ.

1s

Resistance thermometer (RTD)

  • Design of electrical connection for supply voltage

Connector, 3-pole with spring-loaded connection

Connector, 3-pin

  • Connectable conductor cross-sections, solid

1x (0.2 ... 10 mm)

1x (0.75 ... 16 mm)

  • Connectable conductor cross-sections, finely stranded with wire end processing

1x (0.25 ... 6 mm)

1x (0.75 ... 16 mm)

  • Connectable conductor cross-sections for AWG cables

1x (24 ... 8)

1x (18 ... 4)

Power supply for the electronics

Design of the power supply

Power supply via rack

Power

Active power input, max.

1W

Power electronics

Type of load

Ohmic load

Power capacity, max.

16.1kW

27.7kW

48kW

27.7kW

  • for delta connection with fan at 40 C, max.

48kW

  • for delta connection without fan at 40 C, max.

15.6kW

  • for star connection with fan at 40 C, max.

16.1kW

27.7kW

  • for star connection without fan at 40 C, max.

7.3kW

9kW

Switching capacity current per phase, max.

35A

50A

Short-time withstand current (SCCR) acc. to UL 508A

50kA

100kA

100kA

Heating power

  • Number of digital outputs

16

12

8

12

  • Number of heat emitters per output, max.

1

5

1

  • Output voltage for heating power

230V

277V

  • 2nd output voltage for heating power

400V

110V

  • 3rd output voltage for heating power

70V

  • 4th output voltage for heating power

45V

  • Power carrying capacity per output, min.

100W

400W

100W

  • Power carrying capacity per output, max.

1449W

3324W

4432W

9600W

4432W

  • for heating elements with high inrush current, max.

750W

1600W

2760W

1600W

  • Output current for heating power

6.3A

12A

16A

20A

16A

  • Melting I2t value

57As

68As

20As

120As

20As

  • Design of short-circuit protection per output

Safety fuse 6.3 A

Fuse 16 A

Melting fuse 25 A

Fuse 16 A

  • Design of overvoltage protection

Transil Diode

Integration and conversion time/resolution per channel

  • Design of electrical connection at output for heating and fan

Connector, 8-pin with tension spring connection

Connector, 6-pole with spring-loaded connection

Plug, 4-pole, with spring-loaded connection

Connector, 6-pole with spring-loaded connection

  • Connectable conductor cross-sections, solid

1x (0.2 ... 10 mm)

  • Connectable conductor cross-sections, finely stranded with wire end processing

1x (0.25 ... 6 mm)

  • Connectable conductor cross-sections for AWG cables, stranded

1x (24 ... 8)

Interfaces

Interfaces/bus type

system interface

Interrupts/diagnostics/status information

Number of status displays

19

15

11

15

LED status display

LED green = ready, LED yellow = heating on/off, LED red = error display, LED red = error for each channel

Diagnostics function

Voltage diagnostics

Voltage and current diagnosis

Voltage diagnostics

Diagnostic messages

  • Wire-break

Yes

  • Fuse blown

Yes

  • Heat emitter defect

Yes

  • Parallel-connected heating elements

No

Yes

No

Integrated Functions

Monitoring functions

  • Temperature monitoring

Yes

  • Type of temperature monitoring

NTC thermistor

Measuring functions

  • Voltage measurement

No

Yes

No

  • Current measurement

No

Yes

No

Potential separation

Design of electrical isolation

Optocoupler and/or protective impedance between main circuit and PELV

between the outputs

No

Isolation

Overvoltage category

III

Degree of pollution

2

EMC

EMC interference emission

Limit value in accordance with IEC 61000-6-4:2007 + A1:2011

Electrostatic discharge acc. to IEC 61000-4-2

4 kV contact discharge / 8 kV air discharge

Field-related interference acc. to IEC 61000-4-3

10 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz)

Conducted interference due to burst acc. to IEC 61000-4-4

2 kV power supply lines, 2 kV load lines

Conducted interference due to surge acc. to IEC 61000-4-5

Supply and load lines: 1 kV symmetrical, 2 kV asymmetrical

Conducted interference due to high-frequency radiation acc. to IEC 61000-4-6

10 V (0.15 ... 80 MHz)

Degree and class of protection

IP degree of protection

IP20

Standards, approvals, certificates

CE mark

Yes

UL approval

Yes

No

Yes

RCM (formerly C-TICK)

Yes

KC approval

Yes

EAC (formerly Gost-R)

Yes

China RoHS compliance

Yes

Device tag according to DIN EN 81346-2

Q

Ambient conditions

Ambient temperature during operation

  • min.

0C

  • max.

55C

Ambient temperature during storage/transportation

  • Storage, min.

-25C

  • Storage, max.

70C

  • Transportation, min.

-25C

  • Transportation, max.

70C

Air pressure acc. to IEC 60068-2-13

  • Operation, min.

860hPa

  • Operation, max.

1080hPa

  • Storage, min.

660hPa

  • Storage, max.

1080hPa

  • Installation altitude above sea level, max.

2000m

Relative humidity

  • Operation at 25 ℃, max.

95%

  • Operation at 50 ℃, max.

50%; 95 % at 25 C, decreasing linearly to 50 % at 50 C

Vibrations

  • Vibration resistance during operation acc. to IEC 60068-2-6

10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1 g

  • Vibration resistance during storage acc. to IEC 60068-2-6

5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1 g

Shock testing

  • Shock resistance during operation acc. to IEC 60068-2-27

15 g / 11 ms / 3 shocks/axis

  • Shock resistance during storage acc. to IEC 60068-2-29

25 g / 6 ms / 1 000 shocks/axis

Dimensions

Width

36mm

Height

285mm

Depth

281mm



















  © " " 2007-2022