General information | | | |
Product brand name | SIPLUS |
Product designation | POM4220 Lowend | POM4220 Midrange | POM4220 mid-range phase control |
Type of control of heat emitters | Half-wave control | Half-wave control and soft start | Half-wave control, phase control and soft start |
Installation type/mounting | | | |
Mounting type | Screw mounting to rack |
Mounting position | vertical |
Type of ventilation | Self ventilation or forced ventilation |
Supply voltage | | | |
Type of supply voltage | AC |
Rated value (AC) | 230 V | 277 V |
Relative negative tolerance | 10 % | 25 % |
Relative positive tolerance | 10 % | 8 % |
Line frequency | | | |
| 50 Hz |
| 60 Hz |
| 5 % |
Mains buffering | | | |
| 1 s |
Resistance thermometer (RTD) | | | |
| Connector, 3-pole with spring-loaded connection | Connector, 3-pin |
| 1x (0.2 ... 10 mm?) | 1x (0.75 ... 16 mm?) |
| 1x (0.25 ... 6 mm?) | 1x (0.75 ... 16 mm?) |
| 1x (24 ... 8) | 1x (18 ... 4) |
Power supply for the electronics | | | |
Design of the power supply | Power supply via rack |
Power | | | |
Active power input, max. | 1 W |
Power electronics | | | |
Type of load | Ohmic load |
Power capacity, max. | 16.1 kW | 27.7 kW |
| 16.1 kW | 27.7 kW |
| 7.3 kW | 9 kW |
Switching capacity current per phase, max. | 35 A | 50 A |
Heating power | | | |
| 16 | 12 |
| 1 |
| 230 V | 277 V |
| 100 W |
| 1 449 W | 3 324 W | 4 432 W |
| 750 W | 1 600 W |
| 6.3 A | 12 A | 16 A |
| 57 A?·s | 68 A?·s | 120 A?·s |
| Safety fuse 6.3 A | Fuse 16 A |
| Transil Diode |
Integration and conversion time/resolution per channel | | | |
| Connector, 8-pin with tension spring connection | Connector, 6-pole with spring-loaded connection |
| 1x (0.2 ... 10 mm?) |
| 1x (0.25 ... 6 mm?) |
| 1x (24 ... 8) |
Interfaces | | | |
Interfaces/bus type | system interface |
Interrupts/diagnostics/status information | | | |
Number of status displays | 19 | 15 |
LED status display | LED green = ready, LED yellow = heating on/off, LED red = error display, LED red = error for each channel |
Diagnostics function | Voltage diagnostics |
Diagnostic messages | | | |
| Yes |
| Yes |
| Yes |
Integrated Functions | | | |
Monitoring functions | | | |
| Yes |
| NTC thermistor |
Potential separation | | | |
Design of electrical isolation | Optocoupler and/or protective impedance between main circuit and PELV |
between the outputs | No |
Isolation | | | |
Overvoltage category | III |
EMC | | | |
EMC interference emission | Limit value in accordance with IEC 61000-6-4:2007 + A1:2011 |
Electrostatic discharge acc. to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge |
Field-related interference acc. to IEC 61000-4-3 | 10 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz) |
Conducted interference due to burst acc. to IEC 61000-4-4 | 2 kV power supply lines, 2 kV load lines |
Conducted interference due to surge acc. to IEC 61000-4-5 | Supply and load lines: 1 kV symmetrical, 2 kV asymmetrical |
Conducted interference due to high-frequency radiation acc. to IEC 61000-4-6 | 10 V (0.15 ... 80 MHz) |
Degree and class of protection | | | |
IP degree of protection | IP20 |
Standards, approvals, certificates | | | |
Degree of pollution | 2 |
Device tag according to DIN EN 81346-2 | Q |
Ambient conditions | | | |
Ambient temperature during operation | | | |
| 0 °C |
| 55 °C |
Ambient temperature during storage/transportation | | | |
| -25 °C |
| 70 °C |
| -25 °C |
| 70 °C |
Air pressure acc. to IEC 60068-2-13 | | | |
| 860 hPa |
| 1 080 hPa |
| 660 hPa |
| 1 080 hPa |
| 2 000 m |
Relative humidity | | | |
| 95 % |
| 50 %; 95 % at 25 °C, decreasing linearly to 50 % at 50 °C |
Vibrations | | | |
| 10 ... 58 Hz / 0.075 mm, 58 ... 150 Hz / 1 g |
| 5 ... 8.5 Hz / 3.5 mm, 8.5 ... 500 Hz / 1 g |
Shock testing | | | |
| 15 g / 11 ms / 3 shocks/axis |
| 25 g / 6 ms / 1 000 shocks/axis |
Dimensions | | | |
Width | 36 mm |
Height | 285 mm |
Depth | 281 mm |