Application-orientated design of SINAMICSG120SINAMICSG120 standard inverters are modular inverters for standard drives. Selection of the SINAMICSG120 is reduced to two or three steps thanks to the modular system used. Selecting the Control UnitThe optimum Control Unit is selected first, based on the number of I/Os and any additional functions required such as Safety Integrated or HVAC. The communication options are already integrated and do not have to be additionally ordered or plugged in. Threeproduct series are available corresponding to the particular application. CU230P‑2 Control Units The CU230P‑2 Control Units have been specifically designed for pump, fan and compressor applications. Control Unit CU240E‑2 The CU240E‑2 Control Unit is suitable for a wide range of applications in general machine construction, such as conveyor belts, mixers and extruders. CU250S‑2 Control Units The CU250S‑2 Control Units are suitable for applications involving single drives with exacting speed control requirements such as extruders and centrifuges, and for positioning tasks such as conveyor belts, lifting/lowering devices, etc. They can also be used to implement multi-motor drives without DC coupling such as wire-drawing machines and simple material lines.
1) SSM is possible only with PROFIsafe. Optional memory card with firmware V4.7 SP6 for CU230P‑2, CU240E‑2 and CU250S‑2 Control Units
Optional memory cards with licenses for CU250S‑2 Control Units only
For additional information about firmware V4.7 SP6: https://support.industry.siemens.com/cs/document/109482094 Optional memory cards with firmware V4.6 or V4.7 for existing installations when service is required
For an overview and more information on all available firmware versions, see https://support.industry.siemens.com/cs/document/67364620 Selecting the Power ModuleThe optimum power unit can be quickly selected based on the required motor power, the supply voltage and the braking cycles to be expected. Power Modules in degree of protection IP20 are intended for installation in a control cabinet. PM240‑2 and PM240 Power Modules IP20 degree of protection PM240‑2 Power Modules have an integrated braking chopper (four-quadrant applications) and are suitable for a large number of applications in general machinery construction. The same applies for PM240 Power Modules, but the PM240 Power Modules in frame size FSGX do not have an integrated braking chopper. A plug-in Braking Module is optionally available for this purpose. PM250 Power Modules degree of protection IP20 PM250 Power Modules are suitable for the same applications as the PM240‑2/PM240. Any braking energy is directly fed back into the line supply (four-quadrant applications a braking resistor is not required). The Power Modules can be combined with the following Control Units:
PM240, PM240‑2 and PM250 Power Modules
1) Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for low overload (LO). Low overload (LO) generally applies for applications with low dynamic response (continuous operation), quadratic torque characteristic with low break loose torque and low speed accuracy. Examples: Centrifugal pumps, radial/axial fans, rotary piston fans, radial compressors, vacuum pumps, chain conveyors, agitators. High Overload (HO) generally applies for applications with increased dynamic response (cyclic operation) and constant torque characteristics with high break loose torque. Examples: Gear pumps, eccentric worm pumps, mills, mixers, crushers, lifting/lowering gear, centrifuges. 2) The rated output current Irated is based on the duty cycle for low overload (LO). These current values are applicable for 200V, 400V or 690V. 3) 160kW ... 250kW, PM240 Power Modules (frame size FSGX). 4) The PM240‑2 Power Module with Article No. 6SL3210-1PE11-8. L1 corresponds to 0.37kW (0.5 hp) with duty cycle HO. Data based on a duty cycle with low overload (LO). Data based on duty cycle with high overload (HO), see section Power Modules. Selecting optional system componentsIntelligent Operator Panel IOP Graphic display with bar-type diagrams, e.g. for status values suchas pressure or flowrate. User-friendly commissioning, diagnostics and local operator control using a large plain text display, clear menu navigation and application wizards. Intelligent Operator Panel IOP Handheld A handheld version of the IOP can be ordered for mobile use. In addition to the IOP, this includes a housing with rechargeable batteries, charging unit and RS232 connecting cable. Basic Operator Panel BOP-2 Menu navigation and 2-line display permit fast and user-friendly commissioning of the inverter. Simple basic commissioning by simultaneously displaying parameter and parameter value, as well as the option of filtering parameters. Door mounting kit for IOP/BOP‑2 Using the optionally available door mounting kit, the IOP/BOP‑2 can be mounted in a control cabinet door with just a few manual operations (IP54/ULType12 degree of protection is achieved). Push-through mounting frame for Push Through variants of the PM240‑2 Power Modules It is advisable to use an optionally available mounting frame to install the push-through unit in a control cabinet. This mounting frame includes the necessary seals and frame to ensure compliance with degree of protection IP54. If the Power Module is installed without use of the optional mounting frame, the user is responsible for ensuring that the requisite degree of protection is provided. The kit contains all the necessary nuts and seals. Memory card The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced, the drive system is immediately ready for use again. The memory card can also be used to upgrade the firmware of the Control Unit. Brake Relay The Brake Relay allows the Power Module to be connected to an electromechanical motor brake. This allows the motor brake to be controlled directly from the Control Unit. Safe Brake Relay The Safe Brake Relay allows the Power Module to be safely connected to an electromechanical motor brake, allowing the brake to be directly and safely controlled from the CU250S‑2 Control Unit in accordance with IEC61508 SIL2 and ENISO13849‑1 PLd and Category 3. PC inverter connection kit 2 For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool or SINAMICS Startdrive) has been installed. Shield connection kit for Power Modules The shield connection kit makes it easier to connect the shields of supply and control cables, provides mechanical strain relief and thus ensures optimum EMC performance. The shield connection kit is included in the scope of delivery of PM240‑2 Power Modules, frame sizes FSA to FSF. Shield connection kit for Control Units The shield connection kit offers optimum shield connection and strain relief for all signal and communication cables. It includes a matching shield bonding plate and all of the necessary connecting and retaining elements for mounting.
1) Approved only for CU230P‑2HVAC and CU230P‑2DP Control Units with firmware version V4.6 and higher. 2) The STARTER commissioning tool is also available on the Internet at http://www.siemens.com/starter 3) The SINAMICS Startdrive commissioning tool is also available on Internet at https://support.industry.siemens.com/cs/document/68034568 Line-side power componentsThe following line-side power components are available for SINAMICSG120 standard inverters: Line filters With one of the additional line filters, the Power Module attains a higher radio interference class. Line reactors Line reactors smooth the current drawn by the inverter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the inverter. Note: A DC link reactor is integrated in the PM240‑2 Power Modules FSD to FSF and therefore no line reactor is required. Recommended line-side power components Furthermore, this is a recommendation for additional line-side components, such as fuses and circuit breakers (line-side components must be dimensioned in accordance with IEC standards). Additional information about the line-side power components can be found in Catalogs LV10, IC10 and IC10AO as well as the Industry Mall. DC link componentsThe following DC link components are available for the SINAMICSG120 standard inverters: Braking resistors Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with PM240 and PM240‑2 Power Modules. They are equipped with an integrated braking chopper (electronic switch). There is an optional plug-in Braking Module for frame size FSGX. Braking Module A Braking Module and the matching external braking resistor are required to bring drives with a PM240 Power Module, frame sizeFSGX, to a controlled standstill in the event of a power failure (e.g. emergency retraction or EMERGENCY STOP Category1) or to limit the DC link voltage during a short period of generator operation. The Braking Module houses the power electronics and the associated control circuit. Load-side power componentsThe following load-side power components are available for the SINAMICSG120 standard inverters. This means that during operation with output reactors or sine-wave filters, longer, shielded motor cables are possible and the motor service life can be extended: Output reactors Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected. Sine-wave filters Sine-wave filters limit the rate of voltage rise (dv/dt) and the peak voltages on the motor winding. Similar to an output reactor, they enable the connection of longer motor cables. Additional optionsFurther selected supplementary products are available from Siemens Partners. Spare partsSpare parts kit for Control Units The spare parts kit contains small parts for all variants of the following SINAMICSG120 Control Units:
Shield connection kits for PM240‑2 Power Modules A shield connection kit is supplied as standard with PM240‑2 Power Modules in frame sizes FSA to FSF. This shield connection kit is also available as a spare part. Replacement door for PM240 Power Modules, frame size FSGX A complete replacement door can be ordered for the PM240 Power Module, frame size FSGX. Terminal cover kits for frame sizes FSD to FSF The terminal cover kit includes a replacement cover for the connecting terminals. Terminal cover kits which are suitable for the PM240‑2 and PM250 Power Modules are available. Replacement connectors for PM240‑2 Power Modules A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the PM240‑2 Power Module. Fan units for PM240‑2 Power Modules The fans of PM240‑2 Power Modules are designed for extra long service life. For special requirements, replacement fans are available that can be exchanged quickly and easily. Replacement fans for PM240 and PM250 Power Modules The fans of PM240 and PM250 Power Modules are designed for extra long service life. Replacement fans can be ordered for special applications. |
skener.ru Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 DENDOR Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 SKW-FS - Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30 SKW-FK - |
2018 | 2017 | 2016 | 2015 | 2014 | 2013 | 2012 | | | | |