SINAMICS G120 standard inverters
Application-orientated design of SINAMICS G120

SINAMICS G120 standard inverters are modular inverters for standard drives. Selection of the SINAMICS G120 is reduced to two or three steps thanks to the modular system used.

Selecting the Control Unit

The optimum Control Unit is selected first, based on the number of I/Os and any additional functions required such as Safety Integrated or HVAC. The communication options are already integrated and do not have to be additionally ordered or plugged in. Three product series are available corresponding to the particular application.

CU230P?2 Control Units

The CU230P?2 Control Units have been specifically designed for pump, fan and compressor applications.
The CU230P?2 is the Control Unit for the pump, fan and compressor inverters SINAMICS G120P and SINAMICS G120P Cabinet. More information can be found in Catalog D 35.

CU240B?2 and CU240E?2 Control Units

The CU240B?2 and CU240E?2 Control Units are suitable for a wide range of applications in general machine construction, such as conveyor belts, mixers and extruders.

CU250S?2 Control Units

The CU250S?2 Control Units are suitable for applications involving single drives with exacting speed control requirements such as extruders and centrifuges, and for positioning tasks such as conveyor belts, lifting/lowering devices, etc. They can also be used to implement multi-motor drives without DC coupling such as wire-drawing machines and simple material lines.

 

Description

Fieldbus

Profile

Inputs
Outputs

Integrated safety technology

Fail-safe
digital inputs
digital outputs

Control Unit

 

 

 

 

 

 

Article No.

CU230P?2 series - the specialist for pumps, fans, compressors, water, buildings

Technology functions (selection): Free function locks (FFB), 4 ? PID controller, cascade connection, hibernation mode, essential service mode, multi-zone control

CU230P?2 HVAC

  • USS
  • Modbus RTU
  • BACnet MS/TP
  • FLN P1 protocol

6 DI
4 AI

3 DO
2 AO

6SL3243-0BB30-1HA3

CU230P?2 DP

  • PROFIBUS DP
  • PROFIdrive

6SL3243-0BB30-1PA3

CU230P?2 PN

  • PROFINET
  • PROFIdrive
  • PROFIenergy

6SL3243-0BB30-1FA0

  • EtherNet/IP
  • ODVA AC drive
  • SINAMICS profile

CU240B?2 series – for basic applications with variable-speed drives – without encoder

Technology functions (selection): Free function blocks (FFB), 1 ? PID controller, motor holding brake

CU240B?2

  • USS
  • Modbus RTU

4 DI
1 AI

1 DO
1 AO

6SL3244-0BB00-1BA1

CU240B?2 DP

  • PROFIBUS DP
  • PROFIdrive

6SL3244-0BB00-1PA1

CU240E?2 series – for standard applications in general machinery construction, such as conveyor belts, mixers and extruders – without encoder

Technology functions (selection): Free function blocks (FFB), 1 ? PID controller, motor holding brake

CU240E?2

  • USS
  • Modbus RTU

6 DI
2 AI

3 DO
2 AO

STO

1 F-DI
(opt. for each 2 DI)

6SL3244-0BB12-1BA1

CU240E?2 DP

  • PROFIBUS DP
  • PROFIdrive
  • PROFIsafe

6SL3244-0BB12-1PA1

CU240E?2 PN

  • PROFINET
  • PROFIdrive
  • PROFIsafe
  • PROFIenergy

6SL3244-0BB12-1FA0

  • EtherNet/IP
  • ODVA AC drive
  • SINAMICS profile

CU240E?2 F

  • USS
  • Modbus RTU

STO, SS1, SLS, SDI

3 F-DI
(opt. for each 2 DI)

6SL3244-0BB13-1BA1

CU240E?2 DP?F

  • PROFIBUS DP
  • PROFIdrive
  • PROFIsafe

STO, SS1, SLS, SSM 1), SDI

6SL3244-0BB13-1PA1

CU240E?2 PN?F

  • PROFINET
  • PROFIdrive
  • PROFIsafe
  • PROFIenergy

6SL3244-0BB13-1FA0

  • EtherNet/IP
  • ODVA AC drive
  • SINAMICS profile

CU250S?2 series – for complex applications such as extruders and centrifuges – with and without encoder (basic positioner (EPos) optional)

Technology functions (selection): Free function blocks (FFB), 1 ? PID controller, motor holding brake

CU250S?2

  • USS
  • Modbus RTU

11 DI
2 AI

3 DO
2 AO

4 DI/DO (DI can be used as high-speed inputs)

STO, SBC, SS1

3 F-DI
(opt. for each 2 DI)

1 F-DO
(opt. for each 2 DO)

6SL3246-0BA22-1BA0

CU250S?2 DP

  • PROFIBUS DP
  • PROFIdrive
  • PROFIsafe

6SL3246-0BA22-1PA0

CU250S?2 PN

  • PROFINET
  • PROFIdrive
  • PROFIsafe
  • PROFIenergy

6SL3246-0BA22-1FA0

  • EtherNet/IP
  • ODVA AC drive
  • SINAMICS profile

CU250S?2 CAN

  • CANopen

6SL3246-0BA22-1CA0



1) SSM is possible only with PROFIsafe.

Optional memory card with firmware V4.7 SP6 HF1 for CU230P?2, CU240B?2, CU240E?2 and CU250S?2 Control Units

Description

Suitable for

Article No.

SINAMICS SD card

512 MB + firmware V4.7 SP6 HF1 (Multicard V4.7 SP6 HF1)

CU230P?2
CU240B?2
CU240E?2
CU250S?2

6SL3054-7TD00-2BA0



Optional memory cards with licenses for CU250S?2 Control Units only

Description

SINAMICS SD card
512 MB + licenses

SINAMICS SD card
512 MB + firmware V4.7 SP6 HF1 (Multicard V4.7 SP6 HF1) + licenses

Licenses (without SD card)
for upgrading license
of an existing SD card

 

Article No.

Article No.

Article No.

License Extended Functions
Basic positioner (EPos)

6SL3054-4AG00-2AA0-Z

E01

6SL3054-7TD00-2BA0-Z

E01

6SL3074-7AA04-0AA0

License Extended Functions
Safety (SLS, SSM, SDI)

6SL3054-4AG00-2AA0-Z

F01

6SL3054-7TD00-2BA0-Z

F01

6SL3074-0AA10-0AA0

Licenses Extended Functions
Basic positioner (EPos) + Safety (SLS, SSM, SDI)

6SL3054-4AG00-2AA0-Z

E01+F01

6SL3054-7TD00-2BA0-Z

E01+F01



Additional information on firmware V4.7 SP6 HF1:

https://support.industry.siemens.com/cs/document/109482094

Optional memory cards with firmware V4.6 or V4.7 for existing installations when service is required

Description

Suitable for

Article No.

SINAMICS SD card

512 MB + firmware V4.6 (Multicard V4.6)

CU230P?2
CU240B?2
CU240E?2
CU250S?2

6SL3054-7EG00-2BA0

SINAMICS SD card

512 MB + firmware V4.7 (Multicard V4.7)

CU230P?2
CU240B?2
CU240E?2
CU250S?2

6SL3054-7EH00-2BA0



For more information on firmware V4.6:

https://support.industry.siemens.com/cs/document/67385235

For more information on firmware V4.7:

https://support.industry.siemens.com/cs/document/92554110

Selecting the Power Module

The optimum power unit can be quickly selected based on the required motor power, the supply voltage and the braking cycles to be expected. Power Modules in degree of protection IP20 are intended for installation in a control cabinet.

PM230 Power Modules – degree of protection IP20

PM230 Power Modules are designed for applications involving pumps, fans and compressors with a square characteristic. They do not have an integrated braking chopper (single-quadrant applications).

PM230 Power Modules with integrated filter class A or class B, degree of protection IP55/UL Type 12, 0.37 kW to 90 kW (0.5 to 125 hp) are integral components of the SINAMICS G120P for pumps, fans and compressors. More information can be found in Catalog D 35.

PM240?2 and PM240 Power Modules – IP20 degree of protection

PM240?2 Power Modules have an integrated braking chopper (four-quadrant applications) and are suitable for a large number of applications in general machinery construction. The same applies for PM240 Power Modules, but the PM240 Power Modules in frame size FSGX do not have an integrated braking chopper. A plug-in Braking Module is optionally available for this purpose.

PM250 Power Modules – degree of protection IP20

PM250 Power Modules are suitable for the same applications as the PM240?2/PM240. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking resistor is not required).

The Power Modules can be combined with the following Control Units:

Control Units

Power Modules degree of protection IP20

 

PM230 1)

PM240?2/PM240

PM250

CU230P?2

CU240B?2

CU240E?2

CU250S?2



1) PM230 Power Modules with integrated filter class A or class B, degree of protection IP55/UL Type 12, 0.37 kW to 90 kW (0.5 to 125 hp) are integral components of the SINAMICS G120P for pumps, fans and compressors. The CU230P?2 is the Control Unit for SINAMICS G120P and SINAMICS G120P Cabinet for pumps, fans and compressors. More information can be found in Catalog D 35.

 

PM230, PM240 and PM240?2 Power Modules

Rated power 1)

 

Rated output current Irated2)

PM230 Power Module
Degree of protection IP20 3)

The following Control Units are supported: CU230P?2 ..., CU240B?2 ..., CU240E?2 ...

 

PM240?2 Power Modules 4)
Degree of protection IP20

All CUs pluggable

kW

hp

A

Article No.

 

Article No.

200 ... 240 V 1 AC/3 AC

0.55

0.75

3.2

 

6SL3210-1PB13-0?L0

0.75

1

4.2

 

6SL321?-1PB13-8?L0

1.1

1.5

6

 

6SL3210-1PB15-5?L0

1.5

2

7.4

 

6SL3210-1PB17-4?L0

2.2

3

10.4

 

6SL321?-1PB21-0?L0

3

4

13.6

 

6SL3210-1PB21-4?L0

4

5

17.5

 

6SL321?-1PB21-8?L0

200 ... 240 V 3 AC

5.5

7.5

22

 

6SL3210-1PC22-2?L0

7.5

10

28

 

6SL3210-1PC22-8?L0

11

15

42

NEW

6SL3210-1PC24-2UL0

15

20

54

NEW

6SL3210-1PC25-4UL0

18.5

25

68

NEW

6SL3210-1PC26-8UL0

22

30

80

NEW

6SL3210-1PC28-0UL0

30

40

104

NEW

6SL3210-1PC31-1UL0

37

50

130

NEW

6SL3210-1PC31-3UL0

45

60

154

NEW

6SL3210-1PC31-6UL0

55

75

178

NEW

6SL3210-1PC31-8UL0

380 ... 480 V 3 AC

0.37 5)

0.5

1.3

6SL3210-1NE11-3?L1

 

5)

0.55

0.75

1.7

6SL3210-1NE11-7?L1

 

6SL3210-1PE11-8?L1

0.75

1

2.2

6SL3210-1NE12-2?L1

 

6SL3210-1PE12-3?L1

1.1

1.5

3.1

6SL3210-1NE13-1?L1

 

6SL3210-1PE13-2?L1

1.5

2

4.1

6SL3210-1NE14-1?L1

 

6SL3210-1PE14-3?L1

2.2

3

5.9

6SL3210-1NE15-8?L1

 

6SL3210-1PE16-1?L1

3

4

7.7

6SL321?-1NE17-7?L1

 

6SL321?-1PE18-0?L1

4

5

10.2

6SL3210-1NE21-0?L1

 

6SL3210-1PE21-1?L0

5.5

7.5

13.2

6SL3210-1NE21-3?L1

 

6SL3210-1PE21-4?L0

7.5

10

18

6SL321?-1NE21-8?L1

 

6SL321?-1PE21-8?L0

11

15

26

6SL3210-1NE22-6?L1

 

6SL3210-1PE22-7?L0

15

20

32

6SL3210-1NE23-2?L1

 

6SL321?-1PE23-3?L0

18.5

25

38

6SL321?-1NE23-8?L1

NEW

6SL3210-1PE23-8?L0

22

30

45

6SL3210-1NE24-5?L0

NEW

6SL3210-1PE24-5?L0

30

40

60

6SL3210-1NE26-0?L0

NEW

6SL3210-1PE26-0?L0

37

50

75

6SL3210-1NE27-5?L0

NEW

6SL3210-1PE27-5?L0

45

60

90

6SL3210-1NE28-8?L0

NEW

6SL3210-1PE28-8?L0

55

75

110

6SL3210-1NE31-1?L0

NEW

6SL3210-1PE31-1?L0

75

100

145

6SL3210-1NE31-5?L0

NEW

6SL3210-1PE31-5?L0

90

125

178

NEW

6SL3210-1PE31-8?L0

110

150

205

NEW

6SL3210-1PE32-1?L0

132

200

250

NEW

6SL3210-1PE32-5?L0

160

250

302

4)

6SL3224-0XE41-3UA0

200

300

370

4)

6SL3224-0XE41-6UA0

250

400

477

4)

6SL3224-0XE42-0UA0

500 ... 690 V 3 AC

11

10

14

NEW

6SL3210-1PH21-4?L0

15

15

19

NEW

6SL3210-1PH22-0?L0

18.5

20

23

NEW

6SL3210-1PH22-3?L0

22

25

27

NEW

6SL3210-1PH22-7?L0

30

30

35

NEW

6SL3210-1PH23-5?L0

37

40

42

NEW

6SL3210-1PH24-2?L0

45

50

52

NEW

6SL3210-1PH25-2?L0

55

60

62

NEW

6SL3210-1PH26-2?L0

75

75

80

NEW

6SL3210-1PH28-0?L0

90

100

100

NEW

6SL3210-1PH31-0?L0

110

100

115

NEW

6SL3210-1PH31-2?L0

132

125

142

NEW

6SL3210-1PH31-4?L0

Heat sink variant

 

 

             ^

 

             ^

Standard

 

 

             0

 

             0

Push-through

 

 

             1

 

             1

Integrated line filter

 

 

                               ^

 

                               ^

Without

(for IT systems)

 

                               U

 

                               U

Class A

(for TN systems)

 

                               A

 

                               A



1) Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for low overload (LO). Low overload (LO) generally applies for applications with low dynamic response (continuous operation), quadratic torque characteristic with low break loose torque and low speed accuracy. Examples: Centrifugal pumps, radial/axial fans, rotary piston fans, radial compressors, vacuum pumps, chain conveyors, agitators. High Overload (HO) generally applies for applications with increased dynamic response (cyclic operation) and constant torque characteristics with high break loose torque. Examples: Gear pumps, eccentric worm pumps, mills, mixers, crushers, lifting/lowering gear, centrifuges.

2) The rated output current Irated is based on the duty cycle for low overload (LO). These current values are applicable for 200 V, 400 V or 690 V.

3) PM230 Power Modules with integrated filter class A or class B, degree of protection IP55/UL Type 12, 0.37 kW to 90 kW (0.5 to 125 hp) are integral components of the SINAMICS G120P for pumps, fans and compressors. The CU230P?2 is the Control Unit for SINAMICS G120P and SINAMICS G120P Cabinet for pumps, fans and compressors. More information can be found in Catalog D 35.

4) 160 kW ... 250 kW (250 to 400 hp), PM240 Power Modules (frame size FSGX).

5) The PM240?2 Power Module with Article No. 6SL3210-1PE11-8. L1 corresponds to 0.37 kW (0.5 hp) with duty cycle HO.

Data based on a duty cycle with low overload (LO). Data based on duty cycle with high overload (HO), see section Power Modules.

PM250 Power Modules

Rated power 1)

 

Rated output current Irated2)

PM250 Power Module
Degree of protection IP20

All CUs pluggable

kW

hp

A

Article No.

380 ... 480 V 3 AC

7.5

10

18

6SL3225-0BE25-5AA1

11

15

25

6SL3225-0BE27-5AA1

15

20

32

6SL3225-0BE31-1AA1

18.5

25

38

6SL3225-0BE31-5?A0

22

30

45

6SL3225-0BE31-8?A0

30

40

60

6SL3225-0BE32-2?A0

37

50

75

6SL3225-0BE33-0?A0

45

60

90

6SL3225-0BE33-7?A0

55

75

110

6SL3225-0BE34-5?A0

75

100

145

6SL3225-0BE35-5?A0

90

125

178

6SL3225-0BE37-5?A0

Integrated line filter

 

 

                               ^

Without

(for IT systems)

 

                               U

Class A

(for TN systems)

 

                               A

Class B

(for TN systems)

 

Integrated line filter not available, as external option only



1) Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for low overload (LO). Low overload (LO) generally applies for applications with low dynamic response (continuous operation), quadratic torque characteristic with low break loose torque and low speed accuracy. Examples: Centrifugal pumps, radial/axial fans, rotary piston fans, radial compressors, vacuum pumps, chain conveyors, agitators. High Overload (HO) generally applies for applications with increased dynamic response (cyclic operation) and constant torque characteristics with high break loose torque. Examples: Gear pumps, eccentric worm pumps, mills, mixers, crushers, lifting/lowering gear, centrifuges.

2) The rated output current Irated is based on the duty cycle for low overload (LO). These current values are applicable for 400 V.

Data based on a duty cycle with low overload (LO). Data based on duty cycle with high overload (HO), see section Power Modules.

Selecting optional system components

Intelligent Operator Panel IOP

Graphic display with bar-type diagrams, e.g. for status values such as pressure or flowrate.

User-friendly commissioning, diagnostics and local operator control using a large plain text display, clear menu navigation and application wizards.

Intelligent Operator Panel IOP Handheld

A handheld version of the IOP can be ordered for mobile use. In addition to the IOP, this includes a housing with rechargeable batteries, charging unit and RS232 connecting cable.

Basic Operator Panel BOP-2

Menu navigation and 2-line display permit fast and user-friendly commissioning of the inverter.

Simple basic commissioning by simultaneously displaying parameter and parameter value, as well as the option of filtering parameters.

Door mounting kit for IOP/BOP?2

Using the optionally available door mounting kit, the IOP/BOP?2 can be mounted in a control cabinet door with just a few manual operations (IP54/UL Type 12 degree of protection is achieved).

Push-through mounting frame for push-through variants of the PM230 and PM240-2 Power Modules

It is advisable to use an optionally available mounting frame to install the push-through unit in a control cabinet. This mounting frame includes the necessary seals and frame to ensure compliance with degree of protection IP54. If the Power Module is installed without use of the optional mounting frame, the user is responsible for ensuring that the requisite degree of protection is provided. The kit contains all the necessary nuts and seals.

Memory card

The parameter settings for an inverter can be stored on the SINAMICS SD card. When service is required, e.g. after the inverter has been replaced, the drive system is immediately ready for use again. The memory card can also be used to upgrade the firmware of the Control Unit.

Brake Relay

The Brake Relay allows the Power Module to be connected to an electromechanical motor brake, thereby allowing the motor brake to be driven directly by the Control Unit.

Safe Brake Relay

The Safe Brake Relay allows the Power Module to be safely connected to an electromechanical motor brake, allowing the brake to be directly and safely controlled from the CU250S?2 Control Unit in accordance with IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3.

PC inverter connection kit 2

For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool or SINAMICS Startdrive) has been installed.

Shield connection kit for Power Modules

The shield connection kit makes it easier to connect the shields of supply and control cables, provides mechanical strain relief and thus ensures optimum EMC performance. The shield connection kit is included in the scope of supply of the PM230 Power Modules, frame sizes FSA to FSC, and the PM240?2 Power Modules, frame sizes FSA to FSF.

Shield connection kit for Control Units

The shield connection kit offers optimum shield connection and strain relief for all signal and communication cables. It includes a matching shield bonding plate and all of the necessary connecting and retaining elements for mounting.

Description

 

Article No.

Intelligent Operator Panel IOP

 

 

  • German, English, French, Italian, Spanish, Portuguese, Dutch, Swedish, Russian, Czech, Polish, Turkish, Finnish

 

6SL3255-0AA00-4JA1

  • Chinese (simplified), English, German

NEW

6SL3255-0AA00-4JC1

Operator Panel IOP Handheld

 

6SL3255-0AA00-4HA0

Operator Panel BOP?2

 

6SL3255-0AA00-4CA1

Door mounting kit

for IOP/BOP?2

 

6SL3256-0AP00-0JA0

Push-through mounting frame

 

 

  • For PM230 and PM240?2 Power Modules, degree of protection IP20 – push-through variants

 

 

  • Frame size FSA

 

6SL3260-6AA00-0DA0

  • Frame size FSB

 

6SL3260-6AB00-0DA0

  • Frame size FSC

 

6SL3260-6AC00-0DA0

Memory card

 

 

  • SINAMICS SD card 1)
    512 MB

 

6SL3054-4AG00-2AA0

Brake Relay

 

6SL3252-0BB00-0AA0

Safe Brake Relay

 

6SL3252-0BB01-0AA0

PC inverter connection kit 2

 

6SL3255-0AA00-2CA0

Shield plates

 

 

  • For PM230 Power Modules in degree of protection IP20, standard and push-through variants

 

 

  • Frame sizes FSA to FSC

 

Supplied with the Power Modules, available as a spare part

Shield connection kits

 

 

  • For PM230 Power Module in degree of protection IP20

 

 

  • Frame sizes FSD and FSE

 

6SL3262-1AD00-0DA0

  • Frame size FSF

 

6SL3262-1AF00-0DA0

  • For PM240?2 Power Modules

 

 

  • Frame sizes FSA to FSF

 

Supplied with the Power Modules, available as a spare part

  • For PM250 Power Modules

 

 

  • Frame size FSC

 

6SL3262-1AC00-0DA0

  • Frame sizes FSD and FSE

 

6SL3262-1AD00-0DA0

  • Frame size FSF

 

6SL3262-1AF00-0DA0

  • For Control Units

 

 

  • For CU230P?2 HVAC and CU230P?2 DP

 

6SL3264-1EA00-0FA0

  • For CU240B?2 and CU240E?2

 

6SL3264-1EA00-0HA0

  • For CU230P?2 PN, CU240E?2 PN and CU240E?2 PN?F

 

6SL3264-1EA00-0HB0

  • For CU250S?2

 

6SL3264-1EA00-0LA0

STARTER commissioning tool 2)

on DVD?ROM

 

6SL3072-0AA00-0AG0

SINAMICS Startdrive commissioning tool 3)

on DVD?ROM

 

6SL3072-4DA02-0XG0



1) Approved only for CU230P?2 HVAC and CU230P?2 DP Control Units with firmware version V4.6 and higher.

2) The STARTER commissioning tool is also available on the Internet at http://www.siemens.com/starter

3) The SINAMICS Startdrive commissioning tool is also available on Internet at https://support.industry.siemens.com/cs/document/68034568

Line-side power components

The following line-side power components are available for SINAMICS G120 standard inverters:

Line filters

With one of the additional line filters, the Power Module reaches a higher radio interference class.

Line reactors
(only for PM240?2 Power Modules, frame sizes FSA to FSC, and PM240 FSGX)

Line reactors smooth the current drawn by the inverter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the inverter.

Note:

A DC link reactor is integrated in the PM240?2 Power Modules FSD to FSF and therefore no line reactor is required.

Recommended line-side power components

Furthermore, this is a recommendation for additional line-side components, such as fuses and circuit breakers (line-side components must be dimensioned in accordance with IEC standards).

Additional information about the line-side power components can be found in Catalogs LV 10, IC 10 and IC 10 AO as well as the Industry Mall.

DC link components

The following DC link components are available for the SINAMICS G120 standard inverters:

Braking resistors
(for PM240 and PM240?2 Power Modules only)

Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with PM240 and PM240?2 Power Modules. They are equipped with an integrated braking chopper (electronic switch). There is an optional plug-in Braking Module for frame size FSGX.

Braking Module
(for PM240 Power Modules, frame size FSGX only)

A Braking Module and the matching external braking resistor are required to bring drives with a PM240 Power Module, frame size FSGX, to a controlled standstill in the event of a power failure (e.g. emergency retraction or EMERGENCY STOP Category 1) or to limit the DC link voltage during a short period of generator operation. The Braking Module includes the power electronics and the associated control circuit.

Load-side power components

The following load-side power components are available for the SINAMICS G120 standard inverters. This means that during operation with output reactors or sine-wave filters, longer, shielded motor cables are possible and the motor service life can be extended:

Output reactors
(not for PM240-2 Power Modules, frame sizes FSD to FSF, as these have an integrated DC link reactor)

Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.

Sine-wave filter
(not available for PM230 and PM240?2 Power Modules)

Sine-wave filters limit the rate of voltage rise (dv/dt) and the peak voltages on the motor winding. Similar to an output reactor, they enable the connection of longer motor cables.

Additional options

Further selected supplementary products are available from Siemens Partners.
Please select “Drive Options” as the technology in the "Solution Partner Finder” :
http://www.siemens.com/automation/partnerfinder

Spare parts

Spare Parts Kit for Control Units

The Spare Parts Kit contains small parts for all variants of the following SINAMICS G120 Control Units:

  • CU230P?2
  • CU240B?2
  • CU240E?2
  • CU240E?2 F
  • CU250S?2

Shield connection kits for PM240?2 Power Modules

A shield connection kit is supplied as standard with PM240?2 Power Modules in frame sizes FSA to FSF. This shield connection kit is also available as a spare part.

Shield plates for PM230 Power Modules

PM230 Power Modules in degree of protection IP20, frame sizes FSA to FSC, are supplied with a shield plate for motor and signal cables. This shield plate is also available as a spare part.

Replacement door for PM240 Power Modules, frame size FSGX

A complete replacement door can be ordered for the PM240 Power Module, frame size FSGX.

Terminal cover kits for frame sizes FSD to FSF

The terminal cover kit includes a replacement cover for the connecting terminals. Terminal cover kits, which are suitable for the Power Modules PM230 in degree of protection IP20, standard version, PM240?2, and PM250 are available.

Replacement connectors for PM240?2 Power Modules

A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the PM240?2 Power Module.

Fan units for PM230 and PM240?2 Power Modules

The fans of PM230 and PM240-2 Power Modules are designed for extra long service life. For special requirements, replacement fans are available that can be exchanged quickly and easily.

Replacement fans for PM240 and PM250 Power Modules

The fans of PM240 and PM250 Power Modules are designed for extra long service life. Replacement fans can be ordered for special applications.

















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
Êàòàëîã îáîðóäîâàíèÿ 2017
Siemens Industry Catalog Drive Technology Automation Technology Automation Systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial Communication Introduction Industrial Ethernet PROFINET Introduction Drive Systems SINAMICS G SINAMICS G120 standard inverters Control Units SINAMICS G120C compact inverters SINAMICS G120P and G120P Cabinet pump, fan, compressor converters SINAMICS G120D distributed inverters SINAMICS G130 Drive converter chassis units SINAMICS G150 Drive converter cabinet units SINAMICS S high-performance drives SINAMICS medium-voltage drive converter DC converter Controller SIMATIC PCS 7 process control systems Distributed I/O Motion Control Systems CNC Controls Operator panels Industrial PC Switching and Protection Devices for Power Distribution Power Monitoring SENTRON Measuring Devices Configuring, Visualizing and Controlling with SIMATIC Configuring, Visualizing and Controlling with SENTRON Industrial Identification Systems Network Components Industrial Controls SITOP power supplies Software and Tools Network management and diagnostics Technology Components PROFIBUS AS-Interface IO-Link Industrial Wireless Communication Industrial Remote Communication Industrial Security Industrial Controls Manufacturing Execution Systems (MES) SIMATIC IT PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supplies Products for specific requirements Energy Building Technologies Low-Voltage Controls and Distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services ... and everything else you need