Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2018
(4872) 700-366
skenergo@mail.ru

During initial commissioning, please note the following:

Mechanical installation and configuration see operating instructions "SIDOOR ATD400T controller for use with platform screen doors", http://support.automation.siemens.com/WW/view/en/82127712

  • Electrical configuration and commissioning:
    • Push the door into the "CLOSED" position.
    • Open the enclosure cover
    • Plug in the motor plug
    • Connect DC power supply via line filter (SIDOOR EPM24)
    • Press and hold the learn run button
    • The learn run starts automatically and the learn run button can be released.
    • On completion of the learn run, the door is in the "CLOSED" position and the terminal module indicates "u".
    • The door can now be moved via the "OPEN" and "CLOSE" buttons (on the terminal module) with the default profile.

















  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика