Interior railway door driveDuring initial commissioning, please note the following: Mechanical installation and configuration see operating instructions "SIDOOR ATD400T controller for use with platform screen doors", http://support.automation.siemens.com/WW/view/en/82127712 - Electrical configuration and commissioning:
- Push the door into the "CLOSED" position.
- Open the enclosure cover
- Plug in the motor plug
- Connect DC power supply via line filter (SIDOOR EPM24)
- Press and hold the learn run button
- The learn run starts automatically and the learn run button can be released.
- On completion of the learn run, the door is in the "CLOSED" position and the terminal module indicates "u".
- The door can now be moved via the "OPEN" and "CLOSE" buttons (on the terminal module) with the default profile.
|
|