General information | |
Product brand name | SIDOOR |
Product designation | Door controller |
Product version | ATD400T relay |
Optional product expansion | EMC filter |
Manufacturer's article no. of the usable motor | 6FB1103-0AT10-5MA0, 6FB1103-0AT11-5MA0, 6FB1103-0AT10-4MB0, 6FB1103-0AT11-4MB0, 6FB1103-0AT10-3MC0, 6FB1103-0AT11-3MC0 |
Installation type/mounting | |
Installation and mounting instructions | At operating temperatures > 55 °C a sufficiently large (at least 350 mm x 350 mm), unpainted, metal mounting plate must be used |
Supply voltage | |
Rated value (DC) | 24 V |
Input current | |
Current consumption, max. | 15 A |
Digital inputs | |
Control inputs isolated | Yes |
Control inputs p-switching | Yes |
Input voltage | |
| 10 V; Observe polarity ! |
| 28 V; Observe polarity ! |
Input current | |
| 9 mA |
| 27 mA |
Digital outputs | |
Overload-proof | Yes |
Remark | Ensure correct polarity! CAUTION: Do not supply with external voltage! |
Output current | |
| 400 mA |
| 100 mA |
Relay outputs | |
Switching capacity of contacts | |
| 0.01 A; 50 V DC switching voltage not released for NFPA-relevant countries |
| 1 A; 50 V DC switching voltage not released for NFPA-relevant countries |
| 0.01 A |
| 1 A |
Mechanical data | |
Opening width of door, min. | 0.25 m |
Opening width of door, max. | 4 m |
Weight of door, max. | 400 kg |
Operating cycle frequency of door, max. | 180 1/h |
Counterforce, max. | 80 N |
Counterweight | |
| 4 kg |
| 6 kg |
| 8 kg |
Interfaces | |
Interfaces/bus type | without |
Isolation | |
Overvoltage category | 2 |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
CE mark | Yes |
UL approval | No |
Standard for EMC | EN 50121-3-2 |
Ambient conditions | |
Ambient temperature class according to EN 50155 | T3 |
Ambient temperature during operation | |
| -25 °C |
| 70 °C; At operating temperatures > 55 °C the operating parameters are limited to default values |
| At operating temperatures > 55 °C, the maximum air temperature of 85 °C must not be exceeded near the printed-circuit board if temperature class T3 according to EN 50155 is used |
Ambient temperature during storage/transportation | |
| -40 °C |
| 50 °C |
Air pressure acc. to IEC 60068-2-13 | |
| 2 000 m |
Relative humidity | |
| 10 % |
| 93 % |
Fire resistance | |
| complies with EN 45545-2 Hazard Level HL3 |
Dimensions | |
Width | 320 mm |
Height | 60 mm |
Depth | 80 mm |