General technical data: | | |
product brand name | | SIDOOR |
Product designation | | Door controller |
Product expansion optional | | EMC filter |
Supply voltage: | | |
Type of voltage supply | | DC |
Supply voltage at DC Rated value | V | 16.8 |
Consumed current maximum | A | 15 |
Active power consumption | | |
| W | 80 |
| W | 540 |
Inputs/ Outputs: | | |
Input voltage per DC input | V | 10 ... 28 |
Input current per DC input | mA | 9 ... 27 |
Product property | | |
| | Yes |
| | Yes |
Output voltage at DC | V | 24 |
Output current | | |
| mA | 400 |
| mA | 100 |
Property of the 24 V DC output | | |
| | Yes |
| | Yes |
| | CAUTION: Do not supply with external voltage! |
Switching capacity current of the output relay | | |
| A | 0.01 ... 1 |
| A | 0.01 ... 1 |
Door-relevant data: | | |
Door opening width | m | 0.25 ... 4 |
Weight of door maximum | kg | 400 |
Counterweight | | |
| kg | 4 |
| kg | 6 |
| kg | 8 |
Opposing force maximum | N | 80 |
Operating cycle frequency of door maximum | 1/h | 180 |
Ambient conditions: | | |
Ambient temperature during operation | | -25 ... +70 |
| | At operating temperatures > 55°C the operating parameters are limited to default values |
| | At operating temperatures > 55°C, the maximum air temperature of 85°C must not be exceeded near the printed-circuit board if temperature class T3 according to EN 50155 is used |
Ambient temperature during storage | | -40 ... +50 |
Ambient temperature class acc. to EN 50155 | | T3 |
Relative humidity without condensation | % | 10 ... 93 |
Protection class IP | | IP20 |
Installation/ mounting/ dimensions: | | |
Width | mm | 320 |
Height | mm | 60 |
Depth | mm | 80 |
Installation or assembly note | | At operating temperatures > 55°C a sufficiently large (at least 350 x 350 mm), unpainted, metal mounting plate must be used |
Standards: | | |
Certificate of suitability CE marking | | Yes |
Standard for EMC | | EN 50121-3-2 |