The most important directives and standards are listed below. These are used as basis for the SINAMICS S150 converter cabinet units and they must be carefully observed to achieve an EMC-compliant configuration that is safe both functionally and in operation. European directives |
---|
2014/30/EU | EMC Directive: Directive of the European Parliament and Council of February 26, 2014, on the harmonization of the laws of the member states relating to electromagnetic compatibility (recast) | 2006/42/EC | Machinery Directive: Directive of the European Parliament and Council of May 17, 2006, on machinery and amending Directive 95/16/EC (recast). | European standards | EN ISO 3744 | Acoustics – Determination of the sound power level and sound energy level for noise sources that result from sound pressure measurements – envelope surface procedure of the accuracy class 2 for a largely free sound field over a reflecting plane | EN ISO 13849‑1 | Safety of machinery – safety-related parts of control systems; Part 1: General principles for design (ISO 13849-1: 2006) | EN 60146‑1‑1 | Semiconductor converters – General requirements and line-commutated converters Part 1‑1: Specification of basic requirements | EN 60204‑1 | Safety of machinery – Electrical equipment of machines; Part 1: General requirements | EN 60529 | Degrees of protection provided by enclosures (IP Code) | EN 61508‑1 | Functional safety of electrical/electronic/programmable electronic safety-related systems Part 1: General requirements | EN 61800‑2 | Adjustable speed electrical power drive systems Part 2: General requirements; rating specifications for low voltage adjustable frequency AC power drive systems | EN 61800‑3 | Adjustable speed electrical power drive systems Part 3: EMC requirements and specific test methods | EN 61800‑5‑1 | Adjustable speed electrical power drive systems Part 5: Safety requirements Main section 1: Electrical and thermal requirements | EN 61800‑5‑2 | Adjustable speed electrical power drive systems Part 5-2: Safety requirements – Functional safety (IEC 61800‑5‑2: 2007) |
General technical specificationsElectrical specifications |
---|
Line voltages | 380 … 480 V 3 AC, ±10 % (-15 % <1 min) 500 … 690 V 3 AC, ±10 % (-15 % <1 min) | Line supply types | Grounded TN/TT systems and non-grounded IT systems | Line frequency | 47 ... 63 Hz | Output frequency 1) | 0 ... 550 Hz | Line power factor | Adjustable (factory-set to cos φ = 1) | Efficiency | >96 % | Overvoltage category | III to EN 61800‑5‑1 | Control method | Vector control with and without encoder or V/f control | Fixed speeds | 15 fixed speeds plus 1 minimum speed, parameterizable (in the default setting, 3 fixed setpoints plus 1 minimum speed are selectable using terminal block/PROFIBUS/PROFINET) | Skippable speed ranges | 4, parameterizable | Setpoint resolution | 0.001 rpm digital (14 bits + sign) 12 bits analog | Braking operation | Four-quadrant operation is possible as standard (optional via a braking unit if braking is required when power fails) | Mechanical specifications | Degree of protection | IP20 (higher degrees of protection up to IP54 optional) | Protection class | I acc. to EN 61800‑5‑1 | Touch protection | EN 50274/DGUV regulation 3 when used as intended | Cabinet system | Rittal TS 8, doors with double-bit key, three-section base plates for cable entry | Paint finish | RAL 7035 (indoor requirements) | Cooling method | Forced air cooling AF according to EN 60146 | Ambient conditions | Storage 2) | Transport 2) | Operation | Ambient temperature | -25 ... +55 °C | -25 ... +70 °C from -40 °C for 24 hours | 0 ... 40 °C to +50 °C, see derating data | Relative humidity (condensation not permissible) | 5 ... 95% Class 1K4 acc. to IEC 60721‑3‑1 | 5 ... 95 % at 40 °C Class 2K3 acc. to IEC 60721‑3‑2 | 5 ... 95 % Class 3K3 acc. to IEC 60721‑3‑3 | Environmental class/harmful chemical substances | Class 1C2 acc. to IEC 60721‑3‑1 | Class 2C2 acc. to IEC 60721‑3‑2 | Class 3C2 acc. to IEC 60721‑3‑3 | Organic/biological influences | Class 1B1 acc. to IEC 60721‑3‑1 | Class 2B1 acc. to IEC 60721‑3‑2 | Class 3B1 acc. to IEC 60721‑3‑3 | Degree of pollution | 2 acc. to EN 61800‑5‑1 | Installation altitude | Up to 2000 m above sea level without derating; > 2000 m see derating data | Mechanical stability | Storage 2) | Transport 2) | Operation | Vibratory load | Class 1M2 acc. to IEC 60721‑3‑1 | Class 2M2 acc. to IEC 60721‑3‑2 | – | | 1.5 mm at 5 ... 9 Hz | 3.1 mm at 5 ... 9 Hz | 0.075 mm at 10 ... 58 Hz | | 5 m/s² at >9 ... 200 Hz | 10 m/s² at 9 ... 200 Hz | 9.8 m/s2 at 58 ... 200 Hz | Shock load | Class 1M2 acc. to IEC 60721‑3‑1 | Class 2M2 acc. to IEC 60721‑3‑2 | Class 3M4 acc. to IEC 60721‑3‑3 | | 40 m/s² at 22 ms | 100 m/s² at 11 ms | 100 m/s2 at 11 ms | Compliance with standards | Certificates of suitability, according to | CE (EMC Directive 2014/30/EU and Machinery Directive 2006/42/EC for functional safety) RCM | Radio interference suppression | SINAMICS drive converter systems are not designed for connection to the public grid (first environment). Radio interference suppression is compliant with the EMC product standard for variable-speed drives EN 61800‑3, "Second environment" (industrial networks). EMC disturbances can occur when connected to the public grid. However, if additional measures are taken (e.g. → line filter), it can also be operated in the "first environment". |
1) Please note: - The correlation between the maximum output frequency, pulse frequency and current derating. Higher output frequencies on request. - The correlation between the maximum output frequency and permissible output current (current derating). Information is provided in the SINAMICS Low Voltage Engineering Manual. 2) In transport packaging. Deviations from the specified classes are underlined. Line voltage 380 ... 480 V 3 AC | SINAMICS S150 converter cabinet units |
---|
| | 6SL3710-7LE32-1AA3 | 6SL3710-7LE32-6AA3 | 6SL3710-7LE33-1AA3 | 6SL3710-7LE33-8AA3 | 6SL3710-7LE35-0AA3 | 6SL3710-7LE36-1AA3 |
---|
Type rating | | | | | | | | | kW | 110 | 132 | 160 | 200 | 250 | 315 | | kW | 90 | 110 | 132 | 160 | 200 | 250 | | hp | 150 | 200 | 250 | 300 | 400 | 500 | | hp | 150 | 200 | 200 | 250 | 350 | 350 | Output current | | | | | | | | | A | 210 | 260 | 310 | 380 | 490 | 605 | | A | 205 | 250 | 302 | 370 | 477 | 590 | | A | 178 | 233 | 277 | 340 | 438 | 460 | | A | 307 | 375 | 453 | 555 | 715 | 885 | Infeed/regenerative feedback current | | | | | | | | - Rated input current Irated I
| A | 197 | 242 | 286 | 349 | 447 | 549 | - Maximum input current Imax I
| A | 315 | 390 | 570 | 570 | 735 | 907 | Current demand, max. 5) | | | | | | | | - 24 V DC aux. power supply
| A | Internal | Internal | Internal | Internal | Internal | Internal | Pulse frequency 6) | | | | | | | | | kHz | 2 | 2 | 2 | 2 | 2 | 1.25 | | | | | | | | | | kHz | 2 | 2 | 2 | 2 | 2 | 1.25 | | kHz | 8 | 8 | 8 | 8 | 8 | 7.5 | Power loss, max. 7) | | | | | | | | | kW | 6.31 | 7.55 | 10.01 | 10.72 | 13.13 | 17.69 | | kW | 6.49 | 7.85 | 10.45 | 11.15 | 13.65 | 18.55 | Cooling air requirement | m3/s | 0.58 | 0.7 | 1.19 | 1.19 | 1.19 | 1.96 | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 71/73 | 71/73 | 72/74 | 72/74 | 72/74 | 77/79 | Cable length, max. | | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 | Dimensions | | | | | | | | | mm | 1400 | 1400 | 1600 | 1800 | 1800 | 2200 | | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | | mm | 600 | 600 | 600 | 600 | 600 | 600 | Weight (without options), approx. | kg | 708 | 708 | 892 | 980 | 980 | 1716 | Short-circuit current rating according to IEC 8) | kA | 65 | 65 | 65 | 65 | 65 | 65 | Minimum short-circuit current 9) | A | 3000 | 3000 | 4500 | 4500 | 8000 | 12000 | Frame sizes | | | | | | | | | | FI | FI | GI | GI | GI | HI | | | FX | FX | GX | GX | GX | HX | | | FX | FX | GX | GX | GX | HX |
1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 400 V 3 AC 50 Hz. 2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 460 V 3 AC 60 Hz. 3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s. 4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s. 5) If the drive closed-loop control is still to remain active when the line supply fails, the equipment must be provided with an external 24 V DC supply. 6)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual. 7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions. 8) In conjunction with the specified fuses or circuit breakers. 9) Current required for reliably triggering protective devices. Note: The power data in hp units is based on the NEC/CEC standards for the North American market. Information about line supply connections, motor connections and cabinet grounding can be found under Cable cross-sections and connections. Line voltage 380 ... 480 V 3 AC | SINAMICS S150 converter cabinet units |
---|
| | 6SL3710-7LE37-5AA3 | 6SL3710-7LE38-4AA3 | 6SL3710-7LE41-0AA3 | 6SL3710-7LE41-2AA3 | 6SL3710-7LE41-4AA3 |
---|
Type rating | | | | | | | | kW | 400 | 450 | 560 | 710 | 800 | | kW | 315 | 400 | 450 | 560 | 710 | | hp | 600 | 700 | 800 | 900 | 1150 | | hp | 450 | 600 | 700 | 900 | 1000 | Output current | | | | | | | | A | 745 | 840 | 985 | 1260 | 1405 | | A | 725 | 820 | 960 | 1230 | 1370 | | A | 570 | 700 | 860 | 1127 | 1257 | | A | 1087 | 1230 | 1440 | 1845 | 2055 | Infeed/regenerative feedback current | | | | | | | - Rated input current Irated I
| A | 674 | 759 | 888 | 1133 | 1262 | - Maximum input current Imax I
| A | 1118 | 1260 | 1477 | 1891 | 2107 | Current demand, max. 5) | | | | | | | - 24 V DC aux. power supply
| A | Internal | Internal | Internal | Internal | Internal | Pulse frequency 6) | | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | | | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | | kHz | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | Power loss, max. 7) | | | | | | | | kW | 20.63 | 21.1 | 27.25 | 33.05 | 33.95 | | kW | 21.75 | 22.25 | 28.65 | 34.85 | 35.85 | Cooling air requirement | m3/s | 1.96 | 1.96 | 2.6 | 2.6 | 2.6 | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 77/79 | 77/79 | 77/79 | 78/80 | 78/80 | Cable length, max. | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP20 | IP20 | IP20 | IP20 | IP20 | Dimensions | | | | | | | | mm | 2200 | 2200 | 2800 | 2800 | 2800 | | mm | 2000 | 2000 | 2000 | 2000 | 2000 | | mm | 600 | 600 | 600 | 600 | 600 | Weight (without options), approx. | kg | 1731 | 1778 | 2408 | 2408 | 2408 | Short-circuit current rating according to IEC 8) | kA | 65 | 65 | 84 | 100 | 100 | Minimum short-circuit current 9) | A | 15000 | 2000 | 2500 | 3200 | 3200 | Frame sizes | | | | | | | | | HI | HI | JI | JI | JI | | | HX | HX | JX | JX | JX | | | HX | HX | JX | JX | JX |
1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 400 V 3 AC 50 Hz. 2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 460 V 3 AC 60 Hz. 3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s. 4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s. 5) If the drive closed-loop control is still to remain active when the line supply fails, the equipment must be provided with an external 24 V DC supply. 6)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual. 7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions. 8) In conjunction with the specified fuses or circuit breakers. 9) Current required for reliably triggering protective devices. Note: The power data in hp units is based on the NEC/CEC standards for the North American market. Information about line supply connections, motor connections and cabinet grounding can be found under Cable cross-sections and connections. Line voltage 500 ... 690 V 3 AC | SINAMICS S150 converter cabinet units |
---|
| | 6SL3710-7LG28-5AA3 | 6SL3710-7LG31-0AA3 | 6SL3710-7LG31-2AA3 | 6SL3710-7LG31-5AA3 | 6SL3710-7LG31-8AA3 | 6SL3710-7LG32-2AA3 |
---|
Type rating | | | | | | | | | kW | 75 | 90 | 110 | 132 | 160 | 200 | | kW | 55 | 75 | 90 | 110 | 132 | 160 | | kW | 55 | 55 | 75 | 90 | 110 | 132 | | kW | 45 | 55 | 75 | 90 | 90 | 110 | | hp | 75 | 75 | 100 | 150 | 150 | 200 | | hp | 75 | 75 | 100 | 125 | 150 | 200 | Output current | | | | | | | | | A | 85 | 100 | 120 | 150 | 175 | 215 | | A | 80 | 95 | 115 | 142 | 170 | 208 | | A | 76 | 89 | 117 | 134 | 157 | 192 | | A | 120 | 142 | 172 | 213 | 255 | 312 | Infeed/regenerative feedback current | | | | | | | | | A | 86 | 99 | 117 | 144 | 166 | 202 | | A | 125 | 144 | 170 | 210 | 253 | 308 | Current demand, max. 5) | | | | | | | | - 24 V DC aux. power supply
| A | Internal | Internal | Internal | Internal | Internal | Internal | Pulse frequency 6) | | | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | | | | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | | kHz | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | Power loss, max. 7) | | | | | | | | | kW | 5.12 | 5.38 | 5.84 | 5.75 | 11.02 | 11.44 | | kW | 4.45 | 4.65 | 5.12 | 4.97 | 11.15 | 11.56 | Cooling air requirement | m3/s | 0.58 | 0.58 | 0.58 | 0.58 | 1.19 | 1.19 | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 71/73 | 71/73 | 71/73 | 71/73 | 75/77 | 75/77 | Cable length, max. | | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 | Dimensions | | | | | | | | | mm | 1400 | 1400 | 1400 | 1400 | 1600 | 1600 | | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | | mm | 600 | 600 | 600 | 600 | 600 | 600 | Weight (without options), approx. | kg | 708 | 708 | 708 | 708 | 892 | 892 | Short-circuit current rating according to IEC 8) | kA | 65 | 65 | 65 | 65 | 65 | 65 | Minimum short-circuit current 9) | A | 1000 | 1000 | 1300 | 1800 | 2500 | 3000 | Frame size | | | | | | | | | | FI | FI | FI | FI | GI | GI | | | FX | FX | FX | FX | GX | GX | | | FX | FX | FX | FX | GX | GX |
1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 690 V 3 AC 50 Hz. 2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz. 3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s. 4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s. 5) If the drive closed-loop control is still to remain active when the line supply fails, the equipment must be provided with an external 24 V DC supply. 6)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual. 7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions. 8) In conjunction with the specified fuses or circuit breakers. 9) Current required for reliably triggering protective devices. Note: The power data in hp units is based on the NEC/CEC standards for the North American market. Information about line supply connections, motor connections and cabinet grounding can be found under Cable cross-sections and connections. Line voltage 500 … 690 V 3 AC | SINAMICS S150 converter cabinet units |
---|
| | 6SL3710-7LG32-6AA3 | 6SL3710-7LG33-3AA3 | 6SL3710-7LG34-1AA3 | 6SL3710-7LG34-7AA3 | 6SL3710-7LG35-8AA3 | 6SL3710-7LG37-4AA3 |
---|
Type rating | | | | | | | | | kW | 250 | 315 | 400 | 450 | 560 | 710 | | kW | 200 | 250 | 315 | 400 | 450 | 630 | | kW | 160 | 200 | 250 | 315 | 400 | 500 | | kW | 132 | 160 | 200 | 250 | 315 | 450 | | hp | 250 | 300 | 400 | 450 | 600 | 700 | | hp | 200 | 250 | 350 | 450 | 500 | 700 | Output current | | | | | | | | | A | 260 | 330 | 410 | 465 | 575 | 735 | | A | 250 | 320 | 400 | 452 | 560 | 710 | | A | 233 | 280 | 367 | 416 | 514 | 657 | | A | 375 | 480 | 600 | 678 | 840 | 1065 | Infeed/regenerative feedback current | | | | | | | | | A | 242 | 304 | 375 | 424 | 522 | 665 | | A | 370 | 465 | 619 | 700 | 862 | 1102 | Current demand, max. 5) | | | | | | | | - 24 V DC auxiliary power supply
| A | Internal | Internal | Internal | Internal | Internal | Internal | Pulse frequency 6) | | | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | | | | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | | kHz | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | 7.5 | Power loss, max. 7) | | | | | | | | | kW | 11.97 | 12.69 | 19.98 | 20.55 | 24.05 | 30.25 | | kW | 12.03 | 12.63 | 18.86 | 19.47 | 22.85 | 28.75 | Cooling air requirement | m3/s | 1.19 | 1.19 | 1.96 | 1.96 | 1.96 | 2.6 | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 75/77 | 75/77 | 77/79 | 77/79 | 77/79 | 77/79 | Cable length, max. | | | | | | | | | m | 300 | 300 | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | 450 | 450 | Degree of protection | | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 | Dimensions | | | | | | | | | mm | 1600 | 1600 | 2200 | 2200 | 2200 | 2800 | | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | | mm | 600 | 600 | 600 | 600 | 600 | 600 | Weight (without options), approx. | kg | 892 | 892 | 1716 | 1716 | 1716 | 2300 | Short-circuit current rating according to IEC 8) | kA | 65 | 65 | 65 | 65 | 84 | 85 | Minimum short-circuit current 9) | A | 3000 | 4500 | 4500 | 7000 | 9000 | 15000 | Frame size | | | | | | | | | | GI | GI | HI | HI | HI | JI | | | GX | GX | HX | HX | HX | JX | | | GX | GX | HX | HX | HX | JX |
1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 690 V 3 AC 50 Hz. 2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz. 3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s. 4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s. 5) If the drive closed-loop control is still to remain active when the line supply fails, the equipment must be provided with an external 24 V DC supply. 6)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual. 7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions. 8) In conjunction with the specified fuses or circuit breakers. 9) Current required for reliably triggering protective devices. Note: The power data in hp units is based on the NEC/CEC standards for the North American market. Information about line supply connections, motor connections and cabinet grounding can be found under Cable cross-sections and connections. Line voltage 500 … 690 V 3 AC | SINAMICS S150 converter cabinet units |
---|
| | 6SL3710-7LG38-1AA3 | 6SL3710-7LG38-8AA3 | 6SL3710-7LG41-0AA3 | 6SL3710-7LG41-3AA3 |
---|
Type rating | | | | | | | kW | 800 | 900 | 1000 | 1200 | | kW | 710 | 800 | 900 | 1000 | | kW | 560 | 630 | 710 | 900 | | kW | 500 | 560 | 630 | 800 | | hp | 800 | 900 | 1000 | 1250 | | hp | 700 | 800 | 900 | 1000 | Output current | | | | | | | A | 810 | 910 | 1025 | 1270 | | A | 790 | 880 | 1000 | 1230 | | A | 724 | 814 | 917 | 1136 | | A | 1185 | 1320 | 1500 | 1845 | Infeed/regenerative feedback current | | | | | | | A | 732 | 821 | 923 | 1142 | | A | 1218 | 1367 | 1537 | 1905 | Current demand, max. 5) | | | | | | - 24 V DC aux. power supply
| A | Internal | Internal | Internal | Internal | Pulse frequency 6) | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | | | | | | | | kHz | 1.25 | 1.25 | 1.25 | 1.25 | | kHz | 7.5 | 7.5 | 7.5 | 7.5 | Power loss, max. 7) | | | | | | | kW | 34.45 | 34.65 | 36.15 | 42.25 | | kW | 32.75 | 32.85 | 34.25 | 39.25 | Cooling air requirement | m3/s | 2.6 | 2.6 | 2.6 | 2.6 | Sound pressure level LpA (1 m) at 50/60 Hz | dB | 77/79 | 77/79 | 77/79 | 77/79 | Cable length, max. | | | | | | | m | 300 | 300 | 300 | 300 | | m | 450 | 450 | 450 | 450 | Degree of protection | | IP20 | IP20 | IP20 | IP20 | Dimensions | | | | | | | mm | 2800 | 2800 | 2800 | 2800 | | mm | 2000 | 2000 | 2000 | 2000 | | mm | 600 | 600 | 600 | 600 | Weight (without options), approx. | kg | 2408 | 2408 | 2408 | 2408 | Short-circuit current rating according to IEC 8) | kA | 85 | 85 | 85 | 85 | Minimum short-circuit current 9) | A | 2000 | 2000 | 2500 | 3200 | Frame size | | | | | | | | JI | JI | JI | JI | | | JX | JX | JX | JX | | | JX | JX | JX | JX |
1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 690 V 3 AC 50 Hz. 2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz. 3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s. 4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s. 5) If the drive closed-loop control is still to remain active when the line supply fails, the equipment must be provided with an external 24 V DC supply. 6)Information regarding the correlation between the pulse frequency and max. output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual. 7) The specified power losses are the maximum values at 100 % utilization. The values are lower under normal operating conditions. 8) In conjunction with the specified fuses or circuit breakers. 9) Current required for reliably triggering protective devices. Note: The power data in hp units is based on the NEC/CEC standards for the North American market. Information about line supply connections, motor connections and cabinet grounding can be found under Cable cross-sections and connections.
|
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Àðìàòóðà DENDOR
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Äàò÷èêè è èçìåðèòåëè
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ðåãóëÿòîðû è ðåãèñòðàòîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ïíåâìàòè÷åñêîå îáîðóäîâàíèå
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Êðàíû è Êëàïàíû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Èçìåðèòåëüíûå ïðèáîðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Ñèñòåìû áåñïðîâîäíîãî óïðàâëåíèÿ «óìíûé äîì»
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Áåñêîíòàêòíûå âûêëþ÷àòåëè Êîíå÷íûå âûêëþ÷àòåëè Îïòè÷åñêèå äàò÷èêè Ýíêîäåðû
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Óñòàíîâêà óìÿã÷åíèÿ
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Óñòàíîâêà îáåçæåëåçèâàíèÿ
|