Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6GK5307-3BL10-2AA3

6GK5307-3BM10-2AA3

Transmission rate

Transfer rate

10Mbit/s,100Mbit/s,1000Mbit/s

10Mbit/s,100Mbit/s,1000Mbit/s

Interfaces for communication integrated

Number of electrical connections

  • for network components or terminal equipment

7

7

Number of 100 Mbit/s SC ports

  • for multimode

0

0

Number of 1000 Mbit/s LC ports

  • for multimode

0

0

  • for single mode (LD)

0

0

Interfaces others

Number of electrical connections

  • for signaling contact

1

1

  • for power supply

1

1

  • for redundant voltage supply

2

2

Type of electrical connection

  • for signaling contact

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

design of the removable storage

  • C-PLUG

Yes

Yes

Signal-Inputs/outputs

Operating voltage of the signaling contacts

  • at DC Rated value

24V

24V

Operating current of the signaling contacts

  • at DC maximum

0.1A

0.1A

Supply voltage, current consumption, power loss

Type of voltage supply redundant power supply unit

No

No

Type of voltage of the supply voltage

DC

DC

Supply voltage

  • external

24V

24V

  • external minimum

18V

18V

  • external maximum

32V

32V

Product component fusing at power supply input

Yes

Yes

Fuse protection type at input for supply voltage

F 3 A / 32 V

F 3 A / 32 V

Consumed current maximum

0.4A

0.4A

Power loss [W]

  • at DC at 24 V

9.6W

9.6W

Permitted ambient conditions

Ambient temperature

  • during operation

-10...+60C

-40...+60C

  • during storage

-40...+70C

-40...+70C

  • during transport

-40...+70C

-40...+70C

Relative humidity

  • at 25 C without condensation during operation maximum

95%

95%

Protection class IP

IP30

IP30

Design, dimensions and weight

Design

compact

compact

Width

120mm

120mm

Height

125mm

125mm

Depth

123mm

123mm

Net weight

1.4kg

1.4kg

Mounting type

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

  • 19-inch installation

No

No

  • 35 mm DIN rail mounting

Yes

Yes

  • wall mounting

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

  • S7-1500 rail mounting

No

No

Product properties, functions, components general

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

Product function

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • RMON

Yes

Yes

  • Port mirroring

Yes

Yes

  • multiport mirroring

Yes

Yes

  • CoS

Yes

Yes

  • PROFINET IO diagnosis

Yes

Yes

  • switch-managed

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • FTP

Yes

Yes

  • BOOTP

Yes

Yes

  • GMRP

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

Yes

Yes

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Identification & maintenance function

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 higher-level designation/location designation

Yes

Yes

Product functions Diagnosis

Product function

  • Port diagnostics

Yes

Yes

  • Statistics Packet Size

Yes

Yes

  • Statistics packet type

Yes

Yes

  • Error statistics

Yes

Yes

  • SysLog

Yes

Yes

Product functions VLAN

Product function

  • VLAN - port based

Yes

Yes

  • VLAN - protocol-based

No

No

  • VLAN - IP-based

No

No

  • VLAN dynamic

Yes

Yes

Number of VLANs maximum

255

255

Number of VLANs - dynamic maximum

255

255

Protocol is supported GVRP

Yes

Yes

Product functions DHCP

Product function

  • DHCP client

Yes

Yes

  • DHCP Option 82

Yes

Yes

  • DHCP Option 66

Yes

Yes

  • DHCP Option 67

Yes

Yes

Product functions Redundancy

Product function

  • Ring redundancy

Yes

Yes

  • High Speed Redundancy Protocol (HRP)

Yes

Yes

  • high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

  • media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • redundancy procedure STP

Yes

Yes

  • redundancy procedure RSTP

Yes

Yes

  • redundancy procedure MSTP

Yes

Yes

  • Passive listening

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

  • STP

Yes

Yes

  • RSTP

Yes

Yes

  • MSTP

Yes

Yes

  • RSTP big network support

Yes

Yes

  • LACP

Yes

Yes

Product functions Security

Product function

  • ACL - MAC-based

Yes

Yes

  • ACL - port/MAC-based

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • broadcast blocking

Yes

Yes

Protocol is supported

  • SSH

Yes

Yes

Product functions Time

Product function

  • SICLOCK support

Yes

Yes

Protocol is supported

  • NTP

Yes

Yes

  • SNTP

Yes

Yes

  • IEEE 1588 profile default

No

No

Standards, specifications, approvals

Standard

  • for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

Standards, specifications, approvals CE

Certificate of suitability CE marking

Yes

Yes

Standards, specifications, approvals miscellaneous

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • C-Tick

Yes

Yes

  • Railway application in accordance with EN 50155

No

No

  • KC approval

Yes

Yes

Standards, specifications, approvals ship classification

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

  • Germanische Lloyd (GL)

No

No

  • Lloyds Register of Shipping (LRS)

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

  • Polski Rejestr Statkow (PRS)

No

No

  • Royal Institution of Naval Architects (RINA)

No

No

Standards, specifications, approvals product conformity

MTBF at 40 C

10y

20y


Article number

6GK5308-2FL10-2AA3

6GK5308-2FM10-2AA3

6GK5308-2FN10-2AA3

6GK5308-2FP10-2AA3

Transmission rate

Transfer rate

10Mbit/s,100Mbit/s,1000Mbit/s

10Mbit/s,100Mbit/s,1000Mbit/s

10Mbit/s,100Mbit/s,1000Mbit/s

10Mbit/s,100Mbit/s,1000Mbit/s

Interfaces for communication integrated

Number of electrical connections

  • for network components or terminal equipment

8

8

8

8

Number of 100 Mbit/s SC ports

  • for multimode

0

0

0

0

Number of 1000 Mbit/s LC ports

  • for multimode

0

0

0

0

  • for single mode (LD)

0

0

0

0

Interfaces others

Number of electrical connections

  • for signaling contact

1

1

1

1

  • for power supply

1

1

1

1

  • for redundant voltage supply

2

2

2

2

Type of electrical connection

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

design of the removable storage

  • C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

Operating voltage of the signaling contacts

  • at DC Rated value

24V

24V

24V

24V

Operating current of the signaling contacts

  • at DC maximum

0.1A

0.1A

0.1A

0.1A

Supply voltage, current consumption, power loss

Type of voltage supply redundant power supply unit

No

No

No

No

Type of voltage of the supply voltage

DC

DC

DC

DC

Supply voltage

  • external

24V

24V

24V

24V

  • external minimum

18V

18V

18V

18V

  • external maximum

32V

32V

32V

32V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Fuse protection type at input for supply voltage

F 3 A / 32 V

F 3 A / 32 V

F 3 A / 32 V

F 3 A / 32 V

Consumed current maximum

0.4A

0.4A

0.4A

0.4A

Power loss [W]

  • at DC at 24 V

9.6W

9.6W

9.6W

9.6W

Permitted ambient conditions

Ambient temperature

  • during operation

-10...+60C

-40...+60C

-40...+60C

-40...+60C

  • during storage

-40...+70C

-40...+70C

-40...+70C

-40...+70C

  • during transport

-40...+70C

-40...+70C

-40...+70C

-40...+70C

Relative humidity

  • at 25 C without condensation during operation maximum

95%

95%

95%

95%

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

compact

compact

compact

compact

Width

120mm

120mm

120mm

120mm

Height

125mm

125mm

125mm

125mm

Depth

123mm

123mm

123mm

123mm

Net weight

1.4kg

1.4kg

1.4kg

1.4kg

Mounting type

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

  • 19-inch installation

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

  • S7-1500 rail mounting

No

No

No

No

Product properties, functions, components general

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • multiport mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 higher-level designation/location designation

Yes

Yes

Yes

Yes

Product functions Diagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functions VLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN - protocol-based

No

No

No

No

  • VLAN - IP-based

No

No

No

No

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functions DHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

  • media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • MSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functions Security

Product function

  • ACL - MAC-based

Yes

Yes

Yes

Yes

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported

  • SSH

Yes

Yes

Yes

Yes

Product functions Time

Product function

  • SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

Yes

Yes

Yes

Yes

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

Standards, specifications, approvals

Standard

  • for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Standards, specifications, approvals CE

Certificate of suitability CE marking

Yes

Yes

Yes

Yes

Standards, specifications, approvals miscellaneous

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

No

No

No

No

  • KC approval

Yes

Yes

Yes

Yes

Standards, specifications, approvals ship classification

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

  • Germanische Lloyd (GL)

No

No

  • Lloyds Register of Shipping (LRS)

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

  • Polski Rejestr Statkow (PRS)

No

No

  • Royal Institution of Naval Architects (RINA)

No

No

Standards, specifications, approvals product conformity

MTBF at 40 C

25y

25y

25y

25y


Article number

6GK5310-0BA10-2AA3

6GK5310-0FA10-2AA3

6GK5320-1BD00-2AA3

6GK5320-3BF00-2AA3

Transmission rate

Transfer rate

10Mbit/s,100Mbit/s

10Mbit/s,100Mbit/s,1000Mbit/s

10Mbit/s,100Mbit/s

10Mbit/s,100Mbit/s

Interfaces for communication integrated

Number of electrical connections

  • for network components or terminal equipment

10

10

20

20

Number of 100 Mbit/s SC ports

  • for multimode

0

0

1

1

  • for single mode (LD)

2

Number of 1000 Mbit/s LC ports

  • for multimode

0

0

0

0

  • for single mode (LD)

0

0

0

0

Interfaces others

Number of electrical connections

  • for signaling contact

1

1

1

1

  • for power supply

1

1

1

1

  • for redundant voltage supply

2

2

2

2

Type of electrical connection

  • for signaling contact

2-pole terminal block

2-pole terminal block

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

4-pole terminal block

4-pole terminal block

design of the removable storage

  • C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

Operating voltage of the signaling contacts

  • at DC Rated value

24V

24V

24V

24V

Operating current of the signaling contacts

  • at DC maximum

0.1A

0.1A

0.1A

0.1A

Supply voltage, current consumption, power loss

Type of voltage supply redundant power supply unit

No

No

No

No

Type of voltage of the supply voltage

DC

DC

DC

DC

Supply voltage

  • external

24V

24V

24V

24V

  • external minimum

18V

18V

18V

18V

  • external maximum

32V

32V

32V

32V

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Fuse protection type at input for supply voltage

F 3 A / 32 V

F 3 A / 32 V

F 3 A / 32 V

F 3 A / 32 V

Consumed current maximum

0.4A

0.4A

0.4A

0.5A

Power loss [W]

  • at DC at 24 V

9.6W

9.6W

9.6W

12W

Permitted ambient conditions

Ambient temperature

  • during operation

-40...+60C

-40...+60C

-40...+60C

-40...+60C

  • during storage

-40...+70C

-40...+70C

-40...+70C

-40...+70C

  • during transport

-40...+70C

-40...+70C

-40...+70C

-40...+70C

Relative humidity

  • at 25 C without condensation during operation maximum

95%

95%

95%

95%

Protection class IP

IP30

IP30

IP30

IP30

Design, dimensions and weight

Design

compact

compact

compact

compact

Width

120mm

120mm

180mm

180mm

Height

125mm

125mm

125mm

125mm

Depth

123mm

123mm

123mm

123mm

Net weight

1.4kg

1.4kg

1.65kg

1.65kg

Mounting type

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

  • 19-inch installation

No

No

No

No

  • 35 mm DIN rail mounting

Yes

Yes

Yes

Yes

  • wall mounting

Yes

Yes

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

Yes

Yes

  • S7-1500 rail mounting

No

No

No

No

Product properties, functions, components general

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

Product function

  • CLI

Yes

Yes

Yes

Yes

  • web-based management

Yes

Yes

Yes

Yes

  • MIB support

Yes

Yes

Yes

Yes

  • TRAPs via email

Yes

Yes

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

Yes

Yes

  • RMON

Yes

Yes

Yes

Yes

  • Port mirroring

Yes

Yes

Yes

Yes

  • multiport mirroring

Yes

Yes

Yes

Yes

  • CoS

Yes

Yes

Yes

Yes

  • PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • switch-managed

Yes

Yes

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

Yes

Yes

  • HTTP

Yes

Yes

Yes

Yes

  • HTTPS

Yes

Yes

Yes

Yes

  • TFTP

Yes

Yes

Yes

Yes

  • FTP

Yes

Yes

Yes

Yes

  • BOOTP

Yes

Yes

Yes

Yes

  • GMRP

Yes

Yes

Yes

Yes

  • DCP

Yes

Yes

Yes

Yes

  • LLDP

Yes

Yes

Yes

Yes

  • SNMP v1

Yes

Yes

Yes

Yes

  • SNMP v2

Yes

Yes

Yes

Yes

  • SNMP v3

Yes

Yes

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

  • I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • I&M1 higher-level designation/location designation

Yes

Yes

Yes

Yes

Product functions Diagnosis

Product function

  • Port diagnostics

Yes

Yes

Yes

Yes

  • Statistics Packet Size

Yes

Yes

Yes

Yes

  • Statistics packet type

Yes

Yes

Yes

Yes

  • Error statistics

Yes

Yes

Yes

Yes

  • SysLog

Yes

Yes

Yes

Yes

Product functions VLAN

Product function

  • VLAN - port based

Yes

Yes

Yes

Yes

  • VLAN - protocol-based

No

No

No

No

  • VLAN - IP-based

No

No

No

No

  • VLAN dynamic

Yes

Yes

Yes

Yes

Number of VLANs maximum

255

255

255

255

Number of VLANs - dynamic maximum

255

255

255

255

Protocol is supported GVRP

Yes

Yes

Yes

Yes

Product functions DHCP

Product function

  • DHCP client

Yes

Yes

Yes

Yes

  • DHCP Option 82

Yes

Yes

Yes

Yes

  • DHCP Option 66

Yes

Yes

Yes

Yes

  • DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

Product function

  • Ring redundancy

Yes

Yes

Yes

Yes

  • High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

  • media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • redundancy procedure STP

Yes

Yes

Yes

Yes

  • redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • Parallel Redundancy Protocol (PRP)/operation in the PRP-network

Yes

Yes

  • Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)

No

No

  • Passive listening

Yes

Yes

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

Yes

Yes

  • STP

Yes

Yes

Yes

Yes

  • RSTP

Yes

Yes

Yes

Yes

  • MSTP

Yes

Yes

Yes

Yes

  • RSTP big network support

Yes

Yes

Yes

Yes

  • LACP

Yes

Yes

Yes

Yes

Product functions Security

Product function

  • ACL - MAC-based

Yes

Yes

Yes

Yes

  • ACL - port/MAC-based

Yes

Yes

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

Yes

Yes

  • broadcast blocking

Yes

Yes

Yes

Yes

Protocol is supported

  • SSH

Yes

Yes

Yes

Yes

Product functions Time

Product function

  • SICLOCK support

Yes

Yes

Yes

Yes

Protocol is supported

  • NTP

Yes

Yes

Yes

Yes

  • SNTP

Yes

Yes

Yes

Yes

  • IEEE 1588 profile default

No

No

No

No

Standards, specifications, approvals

Standard

  • for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

EN 61000-6-4:2007 (Class A)

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

EN 61000-6-2:2005

Standards, specifications, approvals CE

Certificate of suitability CE marking

Yes

Yes

Yes

Yes

Standards, specifications, approvals miscellaneous

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2:2005, EN 61000-6-4:2007

  • C-Tick

Yes

Yes

Yes

Yes

  • Railway application in accordance with EN 50155

No

No

No

No

  • KC approval

Yes

Yes

Yes

Yes

Standards, specifications, approvals ship classification

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

Yes

Yes

Yes

  • Bureau Veritas (BV)

Yes

Yes

Yes

Yes

  • Det Norske Veritas (DNV)

Yes

Yes

Yes

Yes

  • Germanische Lloyd (GL)

No

No

No

No

  • Lloyds Register of Shipping (LRS)

Yes

Yes

Yes

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

Yes

Yes

Yes

  • Polski Rejestr Statkow (PRS)

No

No

No

No

  • Royal Institution of Naval Architects (RINA)

No

No

No

No

Standards, specifications, approvals product conformity

MTBF at 40 C

40y

40y

25y

15y


Article number

6GK5308-2GG00-2AA2

6GK5308-2GG00-2CA2

Transmission rate

Transfer rate

10Mbit/s,100Mbit/s,1000Mbit/s

10Mbit/s,100Mbit/s,1000Mbit/s

Interfaces for communication integrated

Number of electrical connections

  • for network components or terminal equipment

4

4

Number of 100 Mbit/s ST(BFOC) ports

  • for multimode

4

4

Number of 100 Mbit/s SC ports

  • for multimode

4

4

Number of 1000 Mbit/s LC ports

  • for multimode

4

4

  • for single mode (LD)

4

4

Interfaces others

Number of electrical connections

  • for signaling contact

1

1

  • for media module

2

2

  • for power supply

1

1

  • for redundant voltage supply

1

1

Type of electrical connection

  • for signaling contact

2-pole terminal block

2-pole terminal block

  • for power supply

4-pole terminal block

4-pole terminal block

design of the removable storage

  • C-PLUG

Yes

Yes

Signal-Inputs/outputs

Operating voltage of the signaling contacts

  • at DC Rated value

24V

24V

Operating current of the signaling contacts

  • at DC maximum

0.1A

0.1A

Supply voltage, current consumption, power loss

Type of voltage supply redundant power supply unit

No

No

Type of voltage of the supply voltage

DC

DC

Supply voltage

  • external

24V

12V

  • external minimum

18V

20V

  • external maximum

32V

30V

Supply voltage at DC

24V

  • rated value

20...30V

Product component fusing at power supply input

Yes

Yes

Fuse protection type at input for supply voltage

F 3 A / 32 V

F 3 A / 32 V

Consumed current maximum

0.7A

0.7A

Power loss [W]

  • at DC at 24 V

16.6W

16.6W

Permitted ambient conditions

Ambient temperature

  • during operation

-40...+70C

-40...+70C

  • during storage

-40...+70C

-40...+70C

  • during transport

-40...+70C

-40...+70C

  • Note

Reduced operating temperature through the use of media modules (-40 C to +70 C) or SFP plug-in transceivers (-40 C to +60 C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 C.

Reduced operating temperature through the use of media modules (-40 C to +70 C) or SFP plug-in transceivers (-40 C to +60 C). If the device is installed in the vertical position, the maximum operating temperature is reduced to +50 C.

Relative humidity

  • at 25 C without condensation during operation maximum

95%

95%

Protection class IP

IP20

IP20

Design, dimensions and weight

Design

compact

compact

Width

120mm

120mm

Height

125mm

125mm

Depth

124mm

124mm

Net weight

1.4kg

1.4kg

Product feature conformal coating

Yes

Mounting type

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.

  • 19-inch installation

No

No

  • 35 mm DIN rail mounting

Yes

Yes

  • wall mounting

Yes

Yes

  • S7-300 rail mounting

Yes

Yes

  • S7-1500 rail mounting

No

No

Product properties, functions, components general

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

100

100

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

Product function

  • CLI

Yes

Yes

  • web-based management

Yes

Yes

  • MIB support

Yes

Yes

  • TRAPs via email

Yes

Yes

  • Configuration with STEP 7

Yes

Yes

  • RMON

Yes

Yes

  • Port mirroring

Yes

Yes

  • multiport mirroring

Yes

Yes

  • CoS

Yes

Yes

  • PROFINET IO diagnosis

Yes

Yes

  • switch-managed

Yes

Yes

Protocol is supported

  • Telnet

Yes

Yes

  • HTTP

Yes

Yes

  • HTTPS

Yes

Yes

  • TFTP

Yes

Yes

  • FTP

Yes

Yes

  • BOOTP

Yes

Yes

  • GMRP

Yes

Yes

  • DCP

Yes

Yes

  • LLDP

Yes

Yes

  • SNMP v1

Yes

Yes

  • SNMP v2

Yes

Yes

  • SNMP v3

Yes

Yes

  • IGMP (snooping/querier)

Yes

Yes

Identification & maintenance function

  • I&M0 - device-specific information

Yes

Yes

  • I&M1 higher-level designation/location designation

Yes

Yes

Product functions Diagnosis

Product function

  • Port diagnostics

Yes

Yes

  • Statistics Packet Size

Yes

Yes

  • Statistics packet type

Yes

Yes

  • Error statistics

Yes

Yes

  • SysLog

Yes

Yes

Product functions VLAN

Product function

  • VLAN - port based

Yes

Yes

  • VLAN - protocol-based

No

No

  • VLAN - IP-based

No

No

  • VLAN dynamic

Yes

Yes

Number of VLANs maximum

255

255

Number of VLANs - dynamic maximum

255

255

Protocol is supported GVRP

Yes

Yes

Product functions DHCP

Product function

  • DHCP client

Yes

Yes

  • DHCP Option 82

Yes

Yes

  • DHCP Option 66

Yes

Yes

  • DHCP Option 67

Yes

Yes

Product functions Redundancy

Product function

  • Ring redundancy

Yes

Yes

  • High Speed Redundancy Protocol (HRP)

Yes

Yes

  • high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

  • high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Product function

  • media redundancy protocol (MRP) with redundancy manager

Yes

Yes

  • redundancy procedure STP

Yes

Yes

  • redundancy procedure RSTP

Yes

Yes

  • redundancy procedure MSTP

Yes

Yes

  • Parallel Redundancy Protocol (PRP)/operation in the PRP-network

Yes

Yes

  • Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)

No

No

  • Passive listening

Yes

Yes

Protocol is supported

  • STP/RSTP

Yes

Yes

  • STP

Yes

Yes

  • RSTP

Yes

Yes

  • MSTP

No

Yes

  • RSTP big network support

Yes

Yes

  • LACP

Yes

Yes

Product functions Security

Product function

  • ACL - MAC-based

Yes

Yes

  • ACL - port/MAC-based

Yes

Yes

  • IEEE 802.1x (radius)

Yes

Yes

  • Broadcast/Multicast/Unicast Limiter

Yes

Yes

  • broadcast blocking

Yes

Yes

Protocol is supported

  • SSH

Yes

Yes

Product functions Time

Product function

  • SICLOCK support

Yes

Yes

Protocol is supported

  • NTP

Yes

Yes

  • SNTP

Yes

Yes

  • IEEE 1588 profile default

Yes

Yes

Standards, specifications, approvals

Standard

  • for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC, T4

  • for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • for hazardous zone from CSA and UL

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

UL 1604 and UL 2279-15 (Hazardous Location), CSA C22.2 No. 213-M1987, Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4

  • for emitted interference

EN 61000-6-4:2007 (Class A)

EN 61000-6-4

  • for interference immunity

EN 61000-6-2:2005

EN 61000-6-2

Standards, specifications, approvals CE

Certificate of suitability CE marking

Yes

Yes

Standards, specifications, approvals miscellaneous

Certificate of suitability

EN 61000-6-2:2005, EN 61000-6-4:2007

EN 61000-6-2, EN 61000-6-4

  • C-Tick

Yes

Yes

  • Railway application in accordance with EN 50155

No

Yes

  • Railway application in accordance with EN 50121-4

Yes

  • Fire protection in accordance with EN 45545-2

Yes

  • KC approval

Yes

Yes

Standards, specifications, approvals ship classification

Marine classification association

  • American Bureau of Shipping Europe Ltd. (ABS)

Yes

  • Bureau Veritas (BV)

Yes

  • Det Norske Veritas (DNV)

Yes

  • Germanische Lloyd (GL)

No

  • Lloyds Register of Shipping (LRS)

Yes

  • Nippon Kaiji Kyokai (NK)

Yes

  • Polski Rejestr Statkow (PRS)

No

  • Royal Institution of Naval Architects (RINA)

No

Standards, specifications, approvals product conformity

MTBF at 40 C

40y

40y


















2018
Siemens Industry Catalog Drive technology Automation technology Automation systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Introduction Industrial Ethernet PROFINET Introduction Drive systems Controllers SIMATIC PCS 7 process control systems Distributed I/O Motion control systems CNC controls Operator panels Industrial PC Switching and protection devices for power distribution Power Monitoring SENTRON measuring devices Configuring, Visualizing and Controlling with SIMATIC Configuring, Visualizing and Controlling with SENTRON Industrial identification systems Network components Cabling technology Layer 2 switches Compact switch modules SCALANCE X-000 unmanaged SCALANCE X-100 unmanaged SCALANCE X-200 managed SCALANCE X-200IRT managed SCALANCE X-300 managed SCALANCE X-300 managed SIPLUS SCALANCE X-300 managed SCALANCE XR-300 managed SCALANCE X-300PoE managed SCALANCE XR-300PoE managed SCALANCE X-300EEC managed SCALANCE XR-300EEC managed Media modules for modular SCALANCE X-300 managed SCALANCE X-500 managed Industrial Ethernet Security Industrial wireless LAN Network transitions Industrial controls SITOP power supplies Software and tools Network management and diagnostics Technology components PROFIBUS AS-Interface IO-Link Industrial wireless communication Industrial remote communication Industrial security Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © " " 2007-2022