Suitability for use | Cable for permanent installation in cable channels and pipes, UL approval | Cable for high mechanical loading, for indoor and outdoor installation in cable carriers |
Version of the assembled FO cable | For assembly with fourBFOC or SC connectors | For assembly with fourBFOC or SC connectors |
Optical data | | |
Damping ratio per length | | |
| 3.2dB/km | 3.2dB/km |
| 0.9dB/km | 0.9dB/km |
Bandwidth length product | | |
| 200GHzm | 200GHzm |
| 500GHzm | 500GHzm |
Mechanical data | | |
Number of fibers per FOC core | 1 | 1 |
Number of FO cores per FOC cable | 2 | 2 |
Version of the FO conductor fiber | Multi-mode gradient fiber 62.5/200/230 m | Multi-mode gradient fiber 62.5/200/230 m |
Design of the FOC core | Fixed core | Fixed core |
Design of the fiber-optic cable | Segmentable cable | Segmentable cable |
Outer diameter | | |
| 62.5m | 62.5m |
| 230m | 230m |
| 2.2mm | 2.2mm |
Symmetrical deviation of the outer diameter of the FOC core sheath | 0.1mm | 0.1mm |
Outer diameter of the cable | 7.2mm | 8.8mm |
Symmetrical deviation of the outer diameter of the line | 0.5mm | 0.5mm |
Material | | |
| Quartz glass | Quartz glass |
| ETFE | ETFE |
| PVC | PVC |
| PVC | PUR |
| Aramid fibers | Aramid fibers (double-ply) |
Color | | |
| orange/black | orange/black |
| green | green |
Bending radius | | |
| 70mm | 88mm |
| 105mm | 88mm |
| | 88mm |
Number of bending cycles | | 5000000 |
Tensile load | | |
| 800N | 2000N |
| 100N | 800N |
Short-term shear force per length | 500N/cm | 500N/cm |
Continuous lateral force per length | 300N/cm | 300N/cm |
Weight per length | 49kg/km | 65kg/km |
Permitted ambient conditions | | |
Ambient temperature | | |
| -40...+85C | -25...+75C |
| -40...+85C | -30...+75C |
| -40...+85C | -30...+75C |
| -5...+50C | -5...+50C |
Burning behavior | flame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A) | flame-resistant acc. to IEC 60332-1-2 |
Chemical resistance | | |
| | resistant |
| conditional resistance | resistant |
| conditional resistance | conditional resistance |
Radiological resistance to UV radiation | resistant | resistant |
Product properties, functions, components general | | |
Product feature | | |
| No | No |
| Yes | Yes |
Product component Rodent protection | No | No |
Wire length | | |
| 3000m | 3000m |
| 350m | 350m |
| 550m | 550m |
| 3000m | 3000m |
Standards, specifications, approvals | | |
Certificate of suitability | | |
| Yes | Yes |