- Construction of optical PROFIBUS networks (line, star, ring) with glass, PCF and plastic fiber-optic cables
- High availability can be achieved using a redundant power supply and redundant cable routing
- Function monitoring by means of signaling contact
- All PROFIBUS data transmission rates from 9.6 Kbit/s to 12 Mbit/s including 45.45 Kbit/s for PROFIBUS PA
- Monitoring of the fiber-optic cable routes on LEDs for channel monitoring or using a voltmeter across measurement terminals
Note:SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were adopted from the respective standard products. SIPLUS extreme specific information was added. SIPLUS PROFIBUS | OLM/P11 | OLM/G11 | OLM/G11-1300 |
|---|
Article No. | 6AG1 503-2CA00-2AA0 | 6AG1 503-2CB00-2AA0 | 6AG1 503-2CC00-2AA0 | Article No. based on | 6GK1 503-2CA00 | 6GK1 503-2CB00 | 6GK1 503-2CC00 | Ambient temperature range | -25 … +60 °C | -25 … +60 °C | -25 … +60 °C | Conformal coating | Coating of the printed circuit boards and the electronic components | Technical specifications | The technical data of the standard product applies except for the ambient conditions. |
SIPLUS PROFIBUS | OLM/P12 | OLM/G12 | OLM/G12-1300 |
|---|
Article No. | 6AG1 503-3CA00-2AA0 | 6AG1 503-3CB00-2AA0 | 6AG1 503-3CC00-4AA0 | Article No. based on | 6GK1 503-3CA00 | 6GK1 503-3CB00 | 6GK1 503-3CC00 | Ambient temperature range | -25 … +60 °C | -25 … +60 °C | 0 … +60 °C | Conformal coating | Coating of the printed circuit boards and the electronic components | Technical specifications | The technical data of the standard product applies except for the ambient conditions. |
Ambient conditions | Relative humidity | 100%, condensation/frost permitted. No commissioning in bedewed state. | Biologically active substances, compliance with EN 60721-3-3 | Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation! | Chemically active substances, compliance with EN 60721-3-3 | Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation! | Mechanically active substances, compliance with EN 60721-3-3 | Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation! | Air pressure (depending on the highest positive temperature range specified) | 1 080 ... 795 hPa (-1 000 ... +2 000 m) see ambient temperature range 795 ... 658 hPa (+2000 ... +3500 m) derating 10 K 658 ... 540 hPa (+3500 ... +5000 m) derating 20 K |
Technical documentation on SIPLUS can be found here: http://www.siemens.de/siplus-extreme
|
|