Electrical specifications |
Operating voltage | External 24 V DC necessary | External 24 V DC necessary | External 24 V DC necessary | External 24 V DC necessary | External 24 V DC necessary | External 24 V DC necessary |
Current consumption 1) (from the 24 V DC supply) | | | | | | |
- With Power Module frame sizes FSA and FSB
| 300 mA | 400 mA | 300 mA | 400 mA (FO variant: 520 mA) | 300 mA | 400 mA (FO variant: 520 mA) |
- With Power Module frame size FSC
| 450 mA | 550 mA | 450 mA | 550 mA (FO variant: 670 mA) | 450 mA | 550 mA (FO variant: 670 mA) |
Interfaces |
Digital inputs (non-isolated) | 6 | 6 | 6 | 6 | 6 | 6 |
- Optionally parameterizable as safe inputs
| 1 | 1 | 3 | 3 | 3 | 3 |
Analog inputs (0 ... 10 V) | 2 | 2 | 2 | 2 | – | – |
Digital outputs (0.5 A, fed through switched 24 V DC, isolated) | 2 | 2 | 2 | 2 | 2 | 2 |
- Optionally parameterizable as safe digital output
| – | – | 1 | 1 | 1 | 1 |
Bus interface | | | | | | |
| PROFIBUS DP | PROFINET EtherNet/IP | PROFIBUS DP | PROFINET EtherNet/IP | PROFIBUS DP | PROFINET EtherNet/IP |
| PROFIdrive PROFIsafe | PROFIdrive PROFIsafe PROFIenergy | PROFIdrive PROFIsafe | PROFIdrive PROFIsafe PROFIenergy | PROFIdrive PROFIsafe | PROFIdrive PROFIsafe PROFIenergy |
HTL encoder interface (incremental interface, bipolar up to 2048 pulses, max. 150 mA) | 1 | 1 | 1 | 1 | 1 | 1 |
SSI encoder interface (absolute encoder, single-turn and multi-turn 4096 pulses, 24 V, max. 250 mA) | – | – | – | – | 1 | 1 |
PTC/KTY interface (connection via Power Module) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| 1 input, sensors that can be connected: PTC, KTY, bimetal or Pt1000 | 1 input, sensors that can be connected: PTC, KTY, bimetal or Pt1000 | 1 input, sensors that can be connected: PTC, KTY, bimetal or Pt1000 | 1 input, sensors that can be connected: PTC, KTY, bimetal or Pt1000 | 1 input, sensors that can be connected: PTC, KTY, bimetal or Pt1000 | 1 input, sensors that can be connected: PTC, KTY, bimetal or Pt1000 |
Control of a mechanical motor brake (connection via Power Module) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Slot for SINAMICS SD memory card | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Commissioning interface (mini USB) | ✓ | ✓ | ✓ | ✓ Not with PP and FO variants | ✓ | ✓ Not with PP and FO variants |
Safety functions |
Integrated safety functions acc. to IEC 61508 SIL 2, EN ISO 13849‑1 PL d and Category 3 | | | - Safe Torque Off (STO)
- Safe Stop 1 (SS1)
- Safely-Limited Speed (SLS)
- Safe Direction (SDI)
- Safe Speed Monitor (SSM)
| - Safe Torque Off (STO)
- Safe Stop 1 (SS1)
- Safely-Limited Speed (SLS)
- Safe Direction (SDI)
- Safe Speed Monitor (SSM)
| - Safe Torque Off (STO)
- Safe Stop 1 (SS1)
- Safely-Limited Speed (SLS)
- Safe Direction (SDI)
- Safe Speed Monitor (SSM)
| - Safe Torque Off (STO)
- Safe Stop 1 (SS1)
- Safely-Limited Speed (SLS)
- Safe Direction (SDI)
- Safe Speed Monitor (SSM)
|
Open-loop/closed-loop control techniques |
V/f linear/quadratic/parameterizable | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
V/f with flux current control (FCC) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Vector control, sensorless | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Vector control, with sensor | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Torque control, sensorless | ✓ | ✓ | ✓ | ✓ | – | – |
Torque control, with sensor | ✓ | ✓ | ✓ | ✓ | – | – |
Software functions |
Basic positioner (EPos) | – | – | – | – | ✓ | ✓ |
Fixed frequencies | 16, parameterizable | 16, parameterizable | 16, parameterizable | 16, parameterizable | 16, parameterizable | 16, parameterizable |
Signal interconnection with BICO technology | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Automatic restart after line supply failure or operational fault | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Slip compensation | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Free function blocks (FFB) for logical and arithmetic operations | ✓ | ✓ | ✓ | ✓ | – | – |
Ramp smoothing | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
4 selectable drive datasets | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
4 selectable command data sets (CDS) (manual/auto) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Flying restart | ✓ | ✓ | ✓ | ✓ | – | – |
JOG | ✓ | ✓ | ✓ | ✓ | – | – |
Cyclic recording of ramp-up and ramp-down | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Technology controller (PID) | ✓ | ✓ | ✓ | ✓ | – | – |
Thermal motor protection | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Thermal inverter protection | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Setpoint input | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Motor identification | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Motor holding brake | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Mechanical specifications and ambient conditions |
Operating temperature | -10 ... +55 °C (14 ... 131 °F) | -10 ... +50 °C (14 ... 122 °F) | 0 ... 55 °C (32 ... 131 °F) | 0 ... 50 °C (32 ... 122 °F) (FO variant: 0 ... 45 °C (32 ... 113 °F)) | 0 ... 55 °C (32 ... 131 °F) | 0 ... 50 °C (32 ... 122 °F) (FO variant: 0 ... 45 °C (32 ... 113 °F)) |
Storage temperature | -40 ... +70 °C (-40 ... +158 °F) | -40 ... +70 °C (-40 ... +158 °F) | -40 ... +70 °C (-40 ... +158 °F) | -40 ... +70 °C (-40 ... +158 °F) | -40 ... +70 °C (-40 ... +158 °F) | -40 ... +70 °C (-40 ... +158 °F) |
Relative humidity | < 95 % RH, condensation not permissible | < 95 % RH, condensation not permissible | < 95 % RH, condensation not permissible | < 95 % RH, condensation not permissible | < 95 % RH, condensation not permissible | < 95 % RH, condensation not permissible |
Dimensions | | | | | | |
| 153 mm (6.02 in) | 153 mm (6.02 in) | 153 mm (6.02 in) | 153 mm (6.02 in) | 153 mm (6.02 in) | 153 mm (6.02 in) |
| 208 mm (8.19 in) | 208 mm (8.19 in) | 208 mm (8.19 in) | 208 mm (8.19 in) | 208 mm (8.19 in) | 208 mm (8.19 in) |
| 55 mm (2.17 in) | 55 mm (2.17 in) | 55 mm (2.17 in) | 55 mm (2.17 in) (PP variant: 118 mm (4.65 in)) | 55 mm (2.17 in) | 55 mm (2.17 in) (PP variant: 118 mm (4.65 in)) |
Weight, approx. | 0.8 kg (1.76 lb) | 0.8 kg (1.76 lb) | 0.8 kg (1.76 lb) | 0.8 kg (1.76 lb) (PP and FO variants: 1.3 kg (2.87 lb)) | 0.8 kg (1.76 lb) | 0.8 kg (1.76 lb) (PP and FO variants: 1.3 kg (2.87 lb)) |