Type of construction IM B3
Frame size 90 S/L has frame feet each with 2 drilled holes at NDE.
Types of construction IM B5 and IM V1
For flange dimensions, see flange size (Z = the number of retaining holes)
Type of construction IM B35
For flange dimensions, see flange size (Z = the number of retaining holes)
Frame size 90 S/L has frame feet each with 2 drilled holes at NDE.
Type of construction IM B14
For flange dimensions, see flange size (Z = the number of retaining holes)
For motor |
Dimension designation acc. to IEC | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Frame size |
Type |
Number of poles |
A |
AA |
AB |
AC1) |
AD |
AD' |
AF |
AF' |
AG |
AQ |
AS |
B* |
BA |
BA' |
BB |
BC |
BE |
BE' |
C |
CA* |
H |
HA |
63 M |
1MA7 060 |
2, 4, 6 |
100 |
27 |
120 |
124 |
135 |
101 |
95 |
78 |
120 |
124 |
60 |
80 |
28 |
– |
96 |
52.5 |
32 |
16 |
40 |
66 |
63 |
7 |
1MA7 063 |
||||||||||||||||||||||||
71 M |
1MA7 070 |
2, 4, 6, 8 |
112 |
27 |
132 |
145 |
145 |
111 |
105 |
88 |
120 |
124 |
60 |
90 |
27 |
– |
106 |
41.5 |
32 |
16 |
45 |
83 |
71 |
7 |
1MA7 073 |
||||||||||||||||||||||||
80 M |
1MA7 080 |
2, 4, 6, 8 |
125 |
30.5 |
150 |
163 |
154 |
154 |
114 |
114 |
120 |
124 |
60 |
100 |
32 |
– |
118 |
36 |
32 |
16 |
50 |
94 |
80 |
8 |
1MA7 083 |
1342) |
|||||||||||||||||||||||
90 S |
1MA7 090 |
2, 4, 6, 8 |
140 |
30.5 |
165 |
180 |
162 |
162 |
122 |
122 |
120 |
170 |
60 |
100 |
33 |
54 |
143 |
46 |
32 |
16 |
56 |
143 |
90 |
10 |
90 L |
1MA7 096 |
125 |
118 |
|||||||||||||||||||||
100 L |
1MA7 106 |
2, 4, 6, 8 |
160 |
42 |
196 |
203 |
135 |
163 |
78 |
123 |
120 |
170 |
60 |
140 |
47 |
– |
176 |
39 |
42 |
21 |
63 |
125 |
100 |
12 |
1MA7 107 |
4, 8 |
|||||||||||||||||||||||
112 M |
1MA7 113 |
2, 4, 6, 8 |
190 |
46 |
226 |
227 |
148 |
176 |
91 |
136 |
120 |
170 |
60 |
140 |
47 |
– |
176 |
32 |
42 |
21 |
70 |
141 |
112 |
12 |
132 S |
1MA7130 |
2, 4, 6, 8 |
216 |
53 |
256 |
267 |
167 |
194 |
107 |
154 |
140 |
250 |
70 |
140 |
49 |
– |
180 |
39 |
42 |
21 |
89 |
162.5 |
132 |
15 |
1MA7131 |
2 |
|||||||||||||||||||||||
132 M |
1MA7133 |
4, 6, 8 |
216 |
53 |
256 |
267 |
167 |
194 |
107 |
154 |
140 |
250 |
70 |
178 |
49 |
– |
218 |
39 |
42 |
21 |
89 |
124.5 |
132 |
15 |
1MA7134 |
6 |
162.53) |
||||||||||||||||||||||
160 M |
1MA7163 |
2, 4, 6, 8 |
254 |
60 |
300 |
320 |
197 |
226 |
127 |
183 |
165 |
250 |
82.5 |
210 |
57 |
– |
256 |
52.5 |
54 |
27 |
108 |
183 |
160 |
18 |
1MA7164 |
2, 8 |
|||||||||||||||||||||||
160 L |
1MA7166 |
2, 4, 6, 8 |
254 |
60 |
300 |
320 |
197 |
226 |
127 |
183 |
165 |
250 |
82.5 |
254 |
57 |
– |
300 |
52.5 |
54 |
27 |
108 |
139 |
160 |
18 |
1794) |
* This dimension is assigned in DIN EN 50347 to the frame size listed.
1) Measured across the bolt heads.
2) For 1MA7 083-6.
3) For 1MA7 133-4.
4) For 1MA7 166-4 and 1MA7 166-6.
For motor |
Dimension designation acc. to IEC |
DE shaft extension |
NDE shaft extension | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Frame size |
Type |
Number of poles |
HH |
K |
K’ |
L |
LC |
LL |
LM |
D |
DB |
E |
EB |
ED |
F |
GA |
DA |
DC |
EA |
EC |
EE |
FA |
GC |
63 M |
1MA7 060 |
2, 4, 6 |
92.5 |
7 |
10 |
202.51) |
2321) |
120 |
231.51) |
11 |
M4 |
23 |
16 |
3.5 |
4 |
12.5 |
11 |
M4 |
23 |
16 |
3.5 |
4 |
12.5 |
1MA7 063 |
|||||||||||||||||||||||
71 M |
1MA7 070 |
2, 4, 6, 8 |
86.5 |
7 |
10 |
240 |
278 |
120 |
268 |
14 |
M5 |
30 |
22 |
4 |
5 |
16 |
14 |
M5 |
30 |
22 |
4 |
5 |
16 |
1MA7 073 |
|||||||||||||||||||||||
80 M |
1MA7 080 |
2, 4, 6, 8 |
86 |
9.5 |
13.5 |
273.5 |
324 |
120 |
299.5 |
19 |
M6 |
40 |
32 |
4 |
6 |
21.5 |
19 |
M6 |
40 |
32 |
4 |
6 |
21.5 |
1MA7 083 |
308.52) |
364 |
334.52) |
||||||||||||||||||||
90 S |
1MA7 090 |
2, 4, 6, 8 |
101.5 |
10 |
14 |
331 |
389 |
120 |
382.5 |
24 |
M8 |
50 |
40 |
5 |
8 |
27 |
19 |
M6 |
40 |
32 |
4 |
6 |
21.5 |
90 L |
1MA7 096 |
||||||||||||||||||||||
100 L |
1MA7 106 |
2, 4, 6, 8 |
102 |
12 |
16 |
372 |
438 |
120 |
423.5 |
28 |
M10 |
60 |
50 |
5 |
8 |
31 |
24 |
M8 |
50 |
40 |
5 |
8 |
27 |
1MA7 107 |
4, 8 |
||||||||||||||||||||||
112 M |
1MA7 113 |
2, 4, 6, 8 |
102 |
12 |
16 |
393 |
461 |
120 |
444.5 |
28 |
M10 |
60 |
50 |
5 |
8 |
31 |
24 |
M8 |
50 |
40 |
5 |
8 |
27 |
132 S |
1MA7130 |
2, 4, 6, 8 |
128 |
12 |
16 |
452.53) |
551.5 |
140 |
5053) |
38 |
M12 |
80 |
70 |
5 |
10 |
41 |
38 |
M12 |
80 |
70 |
5 |
10 |
41 |
1MA7131 |
2 |
||||||||||||||||||||||
132 M |
1MA7133 |
4, 6, 8 |
128 |
12 |
16 |
452.53) |
551.5 |
140 |
5053) |
38 |
M12 |
80 |
70 |
5 |
10 |
41 |
38 |
M12 |
80 |
70 |
5 |
10 |
41 |
1MA7134 |
6 |
490.54) |
589.54) |
5434) |
|||||||||||||||||||
160 M |
1MA7163 |
2, 4, 6, 8 |
160.5 |
15 |
19 |
588 |
721 |
165 |
640.5 |
42 |
M16 |
110 |
90 |
10 |
12 |
45 |
42 |
M16 |
110 |
90 |
10 |
12 |
45 |
1MA7164 |
2, 8 |
||||||||||||||||||||||
160 L |
1MA7166 |
2, 4, 6, 8 |
160.5 |
15 |
19 |
588 |
721 |
165 |
640.5 |
42 |
M16 |
110 |
90 |
10 |
12 |
45 |
42 |
M16 |
110 |
90 |
10 |
12 |
45 |
6285) |
7615) |
680.55) |
1)For 1MA7 063 with type of construction code 1 (B5, IM V1 without protective cover, IM V3) the dimensions L, LC and LM are 26 mm longer
2) For 1MA7 083-6.
3) In a low-noise version, the dimension L is 8 mm greater and the dimension LM is 11.5 mm greater.
4) For 1MA7 133-4.
5)For 1MA7 166-4 and 1MA7 166-6.