Order No. supplements
Motor type |
Penultimate position: |
Final position: | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
50 Hz |
Without flange |
With flange |
With standard flange |
With special flange | |||||||
230 V?/400 VY |
400 V?/690 VY |
500 VY |
500 V? |
IM B3/6/7/8, |
IM B5, IM V3 1)3) |
IM V1 with pro |
IM B35 |
IM B14, |
IM B34 |
IM B14 | |
For delta connection, overload protection with phase-failure protection must be provided. | |||||||||||
1 |
6 |
3 |
5 |
0 |
1 |
4 |
6 |
2 |
7 |
3 | |
1MA6 10 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
1MA6 11 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
1MA6 13 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
1MA6 16 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
1MA6 18 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
– |
– |
– |
1MA6 20 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
– |
– |
– |
1MA6 22 . ? . . . ?? |
O |
O |
O |
O |
? |
?5) |
? |
? |
– |
– |
– |
1MA6 25 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
– |
– |
– |
1MA6 28 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
– |
– |
– |
1MA6 310 ? . . . ??1MA6 313 ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
– |
– |
– |
1MA6 316 ? . . . ??1MA6 317 ? . . . ??1MA6 318 ? . . . ?? |
– |
O |
O |
O |
? 6) |
– |
? 7) |
? |
– |
– |
– |
? Standard version
O Without additional charge
? With additional charge
– Not possible
Order other voltages with voltage code9 in the penultimate position and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Voltages").
Order other types of construction with type of construction code9 in the final position and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Types of construction").
1)The following applies for explosion-proof motors: In the case of the types of construction with shaft end down, the version "with protective cover" is required. For types of construction with shaft extension pointing upwards, a suitable cover must be implemented to prevent small parts from falling into the fan cover (see the standard IEC/EN 60079-0). The cover must not block the cooling air-flow.
2)If motors 1MA6 183-... to 1MA6 318-... (motor series 1MA6 frame sizes 180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6 are fixed to the wall, it is recommended that the motor feet are supported.
3)1MA6 220-... to 1MA6 318-... motors (motor series 1MA6 frame sizes 225 S to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5, whereby one can be relocated in accordance with IM V1 or IM V3. It is important to note that stress must not be applied perpendicular to the ring plane.
4)The "Second shaft extension" option, order codeK16 is not possible.
5)Type of construction IM V3 is only possible using type of construction code9 and order codeM1G.
6)Type of construction IM V6 is only possible using type of construction code9 and order codeM1E.
7)2-pole motors in 60 Hz version available on request.