Siemens
(4872) 700-366
skenergo@mail.ru
Self ventilated, type of prot d, Zone 1 - cast-iron series 1MJ6/7
Order No. supplements

Motor type

Penultimate position:
Voltage code

Final position:
Type of construction code

50Hz

Without flange

With flange

With standard flange

With special flange

230V?/400VY

400V?/690VY

500VY

500V?

IMB3/6/7/8,
IMV61)2)

IMB5, IMV31)3)

IM V1 with protective cover1)3)4)

IMB35

IMB14,
IMV191)

IMB34

IMB14
IMV191)

1

6

3

5

0

1

4

6

2

7

3

1MJ607.?...??

O

O

O

?

?

?

?

?

?

?

1MJ608.?...??

O

O

O

?

?

?

?

?

?

?

1MJ609.?...??

O

O

O

?

?

?

?

?

?

1MJ610.?...??

O

O

O

O

?

?

?

?

1MJ611.?...??

O

O

O

O

?

?

?

?

1MJ613.?...??

O

O

O

O

?

?

?

?

1MJ616.?...??

O

O

O

O

?

?

?

?

1MJ618.?...??

O

O

O

O

?

?5)

?

?

1MJ620.?...??

O

O

O

O

?

?5)

?

?

1MJ722.?...??

O

O

O

O

?

?5)

?

?

1MJ725.?...??

O

O

O

O

?

?5)

?

?

1MJ728.?...??

O

O

O

O

?

?5)

?

?

1MJ731.?...??

O

O

O

O

?

?5)

?

?


? Standard version

O Without additional charge

? With additional charge

Not possible

Order other voltages with voltage code9in the penultimate position and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Voltages").

Order other types of construction with type of construction code9 in the final position and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Types of construction").

1)The following applies for explosion-proof motors: In the case of the types of construction with shaft end down, the version "with protective cover" is required. For types of construction with shaft extension pointing upwards, a suitable cover must be implemented to prevent small parts from falling into the fan cover (see the standard IEC/EN60079-0). The cover must not block the cooling air-flow.

2)If motors 1MJ6183-... to 1MJ7313-... (motor series 1MJ6 frame size 180M and above to 1MJ7 frame size 315M) in types of construction with feet IMB6, IMB7 or IM V6 are fixed to the wall, it is recommended that the motor feet are supported.

3)1MJ7220-... to 1MJ7313-... motors (motor series 1MJ7 frame sizes 225S to 315M) are supplied with two screw-in eyebolts in accordance with IMB5, whereby one can be relocated in accordance with IMV1 or IMV3. It is important to note that stress must not be applied perpendicular to the ring plane.

4)The "Second shaft extension" option, order codeK16 is not possible.

5)Type of construction IMV3 is only possible using type of construction code9 and order codeM1G.



  © " " 2007-2016
  (4872) 700-366
.