Tested component designThe complete system consists of the following tested individual components: - Sampling probe: M&C, type: SP2000; Bühler/Siemens, type: GAS222/7MB1943‑2F
- Heated sample gas line: Winkler/Siemens, type: 7MB1943‑2A
- Temperature controller: Siemens, type: SIRIUS
- Two-stage compressor gas cooler: M&C, type: CSS; Bühler, type: EGK 2‑19
- Sample gas pump: BГјhler/Siemens, type: P2.3/7MB1943-3C
- NOX converter: M&C, type: CG-2
Design of measuring instruments checked for suitabilityThe modular measuring system Set CEM CERT can consist of one or up to three of the following analyzers in combination with a system cabinet. The analyzer checked for suitability is selected separately from the system based on the specific article number. Analyzer | Article number of the analyzer | Design |
|---|
ULTRAMAT 23 | 7MB2358-.....-.... | 3 NDIR components on 2 optical benches | ULTRAMAT 23 | 7MB2357-.....-.... | 2 NDIR components on 2 optical benches | ULTRAMAT 23 | 7MB2355-.....-.... | 1 NDIR component on 1 optical bench | SIPROCESS UV600 | 7MB2621-.....-.... | 3 UV components on 1 optical bench | ULTRAMAT 6 | 7MB2121-.....-.... 7MB2011-.....-.... | 1 NDIR component on 1 optical bench | ULTRAMAT 6; two-channel 19" rack unit | 7MB2123-.....-.... 7MB2124-.....-.... | 2 NDIR components on 2 optical benches | OXYMAT 6 | 7MB2021-.....-.... | 1 paramagnetic O2 measuring cell | ULTRAMAT / OXYMAT 6 | 7MB2023-.....-.... 7MB2024-.....-.... | 1 NDIR component on 1 optical bench and 1 paramagnetic O2 sample chamber |
NDIR = Non-dispersive infrared sensor
|
|