General information | |
Firmware version | V2.0 |
Product function | |
| Yes |
| Yes |
| Yes |
| No |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes; I&M 0 |
| No |
Engineering with | |
| V13 SP1 |
Operating mode | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Configuration control | |
via dataset | Yes |
CiR – Configuration in RUN | |
Reparameterization possible in RUN | Yes |
Calibration possible in RUN | Yes |
Installation type/mounting | |
Mounting position | Horizontal, vertical |
Supply voltage | |
Design of the power supply | Supply via voltage measurement channel L1 |
Type of supply voltage | AC 100 - 277 V |
permissible range, lower limit (AC) | 90 V |
permissible range, upper limit (AC) | 293 V |
Line frequency | |
| 47 Hz |
| 63 Hz |
Power loss | |
Power loss, typ. | 0.6 W |
Address area | |
Address space per module | |
| 124 byte; 112 byte input / 12 byte output |
Time of day | |
Operating hours counter | |
| Yes |
Analog inputs | |
Cycle time (all channels), typ. | 50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data) |
Interrupts/diagnostics/status information | |
Alarms | |
| Yes |
| Yes |
| No |
Diagnostics indication LED | |
| Yes |
| Yes; Green LED |
| Yes; red Fn LED |
| Yes; green/red DIAG LED |
Integrated Functions | |
Measuring functions | |
| TRMS |
| TRMS |
| seamless |
| Sinusoidal or distorted |
| Yes |
| 74 byte |
| 2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz |
Operating mode for measured value acquisition | |
| No; Parameterizable |
Measuring range | |
| 45 Hz |
| 65 Hz |
Measuring inputs for voltage | |
| 277 V |
| 480 V |
| 90 V |
| 293 V |
| 155 V |
| 508 V |
| CAT II; CAT III in case of guaranteed protection level of 1.5 kV |
| 3.4 MΩ |
| 20 mW |
| 1 kV |
Measuring inputs for current | |
| 1 %; Relative to the secondary rated current 5 A |
| 100 %; Relative to the secondary rated current 5 A |
| 5 A |
| 0.6 V·A |
| 100 A |
| 25 mΩ; At the terminal |
| Parameterizable: 2 ... 250 mA, default 50 mA |
| 10 A; for 1 minute |
Accuracy class according to IEC 61557-12 | |
| 0,2 |
| 0,2 |
| 0.5 |
| 0.5 |
| 1 |
| 0.5 |
| 0.5 |
| 1 |
| 0.5; calculated |
| ±1 °; not covered by IEC 61557-12 |
| 0.05 |
Potential separation | |
Potential separation channels | |
| Yes; 3 700V AC (type test) CAT III |
Isolation | |
Isolation tested with | 2 300V AC for 1 min. (type test) |
Ambient conditions | |
Ambient temperature during operation | |
| -20 °C |
| 60 °C |
| -20 °C |
| 50 °C |
Dimensions | |
Width | 45 mm |
Height | 100 mm |
Depth | 75 mm |
Weights | |
Weight (without packaging) | 165 g |
Data for selecting a current transformer | |
| As a function of cable length and cross section, see device manual |
| As a function of cable length and cross section, see device manual |