General information | |
Product type designation | AI 4xU/I/RTD/TC /AQ 2xU/I ST |
HW functional status | FS01 |
Firmware version | V1.0.0 |
| Yes |
Product function | |
| Yes; I&M0 to I&M3 |
| No |
| No |
| No |
| No |
Engineering with | |
| V13 / V13.0.2 |
| V5.5 SP3 / - |
| V1.0 / V5.1 |
| V2.3 / - |
Operating mode | |
| No |
| Yes |
| Yes |
CiR Configuration in RUN | |
Reparameterization possible in RUN | Yes |
Calibration possible in RUN | Yes |
Supply voltage | |
Rated value (DC) | 24V |
permissible range, lower limit (DC) | 20.4V |
permissible range, upper limit (DC) | 28.8V |
Reverse polarity protection | Yes |
Input current | |
Current consumption, max. | 200mA; with 24 V DC supply |
Encoder supply | |
24 V encoder supply | |
| Yes |
| 20mA; Max. 47 mA per channel for a duration < 10 s |
Power | |
Power available from the backplane bus | 0.7W |
Power loss | |
Power loss, typ. | 3.3W |
Analog inputs | |
Number of analog inputs | 4 |
| 4 |
| 4 |
| 2 |
| 4 |
permissible input voltage for voltage input (destruction limit), max. | 28.8V |
permissible input current for current input (destruction limit), max. | 40mA |
Technical unit for temperature measurement adjustable | Yes; C/F/K |
Analog input with oversampling | No |
Standardization of measured values | No |
Input ranges (rated values), voltages | |
| No |
| No |
| Yes |
| 100kΩ |
| Yes |
| 10MΩ |
| Yes |
| 100kΩ |
| Yes |
| 10MΩ |
| No |
| Yes |
| 10MΩ |
| Yes |
| 100kΩ |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
Input ranges (rated values), currents | |
| Yes |
| 25Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Yes |
| 25Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
| Yes |
| 25Ω; Plus approx. 42 ohms for overvoltage protection by PTC |
Input ranges (rated values), thermocouples | |
| Yes |
| 10MΩ |
| No |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| No |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| No |
| No |
Input ranges (rated values), resistance thermometer | |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| Yes; Standard/climate |
| 10MΩ |
| No |
| Yes; Standard/climate |
| 10MΩ |
| No |
| Yes; Standard/climate |
| 10MΩ |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| No |
| Yes; Standard/climate |
| 10MΩ |
| No |
| Yes; Standard/climate |
| 10MΩ |
| No |
| Yes; Standard/climate |
| 10MΩ |
| No |
| Yes; Standard/climate |
| 10MΩ |
| No |
Input ranges (rated values), resistors | |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
| No |
| Yes |
| 10MΩ |
| Yes |
| 10MΩ |
Thermocouple (TC) | |
Temperature compensation | |
| Yes |
| Yes |
| Yes |
| Yes; fixed value can be set |
| No |
Cable length | |
| 800m; for U/I, 200 m for R/RTD, 50 m for TC |
Analog outputs | |
Number of analog outputs | 2 |
Voltage output, short-circuit protection | Yes |
Voltage output, short-circuit current, max. | 24mA |
Current output, no-load voltage, max. | 22V |
Cycle time (all channels), min. | 3.2ms; 0.5 ms, regardless of the number of activated channels |
Output ranges, voltage | |
| Yes |
| Yes |
| No |
| Yes |
Output ranges, current | |
| Yes |
| Yes |
| Yes |
Connection of actuators | |
| Yes |
| Yes |
| Yes |
Load impedance (in rated range of output) | |
| 1kΩ; 0.5 kOhm at 1 to 5 V |
| 1F |
| 750Ω |
| 10mH |
Cable length | |
| 800m; for current, 200 m for voltage |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
| 16bit |
| Yes |
| 2,5 / 16,67 / 20 / 100 ms |
| 9 / 23 / 27 / 107 ms |
| 9 ms |
| 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms |
| 400 / 60 / 50 / 10 |
| Basic conversion time of the slowest channel |
Smoothing of measured values | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Analog value generation for the outputs | |
Integration and conversion time/resolution per channel | |
| 16bit |
| 0.5ms |
Settling time | |
| 1.5ms |
| 2.5ms |
| 2.5ms |
Encoder | |
Connection of signal encoders | |
| Yes |
| Yes |
| 820Ω |
| Yes |
| Yes; Only for PTC |
| Yes; All measuring ranges except PTC; internal compensation of the cable resistances |
| Yes; All measuring ranges except PTC |
Errors/accuracies | |
Linearity error (relative to input range), (+/-) | 0.02% |
Temperature error (relative to input range), (+/-) | 0.005%/K; With TC type T 0.02 % / K |
Crosstalk between the inputs, max. | -80dB |
Repeat accuracy in steady state at 25 C (relative to input range), (+/-) | 0.02% |
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) | 0.02% |
Linearity error (relative to output range), (+/-) | 0.15% |
Temperature error (relative to output range), (+/-) | 0.002%/K |
Crosstalk between the outputs, max. | -100dB |
Repeat accuracy in steady state at 25 C (relative to output range), (+/-) | 0.05% |
Temperature error of internal compensation | 6 C |
Operational error limit in overall temperature range | |
| 0.3% |
| 0.3% |
| 0.3% |
| 0.3%; Ptxxx standard: 1.5 K, Ptxxx climate: 0.5 K, Nixxx standard: 0.5 K, Nixxx climate: 0.3 K |
| 0.3%; Type B: > 600 C 4.6 K, type E: > -200 C 1.5 K, type J: > -210 C 1.9 K, type K: > -200 C 2.4 K, type N: > -200 C 2.9 K, type R: > 0 C 4.7 K, type S: > 0 C 4.6 K, type T: > -200 C 2.4 K |
| 0.3% |
| 0.3% |
Basic error limit (operational limit at 25 C) | |
| 0.1% |
| 0.1% |
| 0.1% |
| 0.1%; Ptxxx standard: 0.7 K, Ptxxx climate: 0.2 K, Nixxx standard: 0.3 K, Nixxx climate: 0.15 K |
| 0.1%; Type B: > 600 C 1.7 K, type E: > -200 C 0.7 K, type J: > -210 C 0.8 K, type K: > -200 C 1.2 K, type N: > -200 C 1.2 K, type R: > 0 C 1.9 K, type S: > 0 C 1.9 K, type T: > -200 C 0.8 K |
| 0.2% |
| 0.2% |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | |
| 40dB |
| 10V |
| 60dB |
Isochronous mode | |
Isochronous operation (application synchronized up to terminal) | No |
Interrupts/diagnostics/status information | |
Diagnostics function | Yes |
Substitute values connectable | Yes |
Alarms | |
| Yes |
| Yes; two upper and two lower limit values in each case |
Diagnostic messages | |
| Yes |
| Yes; only for input type 1 ... 5 V, 4 ... 20 mA, TC, R, RTD and output type current |
| Yes; Only for output type "voltage" |
| Yes |
Diagnostics indication LED | |
| Yes; Green LED |
| Yes; Red LED |
| Yes; Green LED |
| Yes; Green LED |
| Yes; Red LED |
| Yes; Red LED |
Potential separation | |
Potential separation analog inputs | |
| No |
| 4 |
| Yes |
| Yes |
Potential separation analog outputs | |
| No |
| 2 |
| Yes |
| Yes |
Permissible potential difference | |
between the inputs (UCM) | 20 V DC |
Between the inputs and MANA (UCM) | 10 V DC |
between S- and MANA (UCM) | 8 V DC |
Isolation | |
Isolation tested with | 707 V DC (type test) |
Ambient conditions | |
Ambient temperature during operation | |
| 0C |
| 60C |
| 0C |
| 40C |
Decentralized operation | |
Prioritized startup | No |
Dimensions | |
Width | 25mm |
Height | 147mm |
Depth | 129mm |
Weights | |
Weight, approx. | 250g |
Other | |
Note: | Supplied incl. 40-pole push-in front connectors. Additional basic error and noise for integration time = 2.5 ms: Voltage: 250 mV (0.02%), 80 mV (0.05%), 50 mV (0.05%); resistance: 150 Ohms (0.02%); resistance thermometer: Pt100 climate: 0.08 K, Ni100 climate: 0.08 K; thermoelement: Type B, R, S: 3 K, type E, J, K, N, T: 1 K |