Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6ES7552-1AA00-0AB0

S7-1500, TM TIMER DIDQ 16X24V

General information

 

Product type designation

TM Timer DIDQ 16x24V

Product function

 

  • в—Џ I&M data

Yes; I&M 0

Engineering with

 

  • в—Џ STEP 7 TIA Portal configurable/integrated as of version

V13 Update 3

Installation type/mounting

 

Rail mounting

Yes; S7-1500 mounting rail

Load voltage 1L+

 

  • в—Џ Rated value (DC)

24 V

  • в—Џ permissible range, lower limit (DC)

19.2 V

  • в—Џ permissible range, upper limit (DC)

28.8 V

  • в—Џ Reverse polarity protection

Yes; against destruction

Load voltage 2L+

 

  • в—Џ Rated value (DC)

24 V

  • в—Џ permissible range, lower limit (DC)

19.2 V

  • в—Џ permissible range, upper limit (DC)

28.8 V

  • в—Џ Reverse polarity protection

Yes; against destruction

Input current

 

from load voltage 1L+ (without load), max.

40 mA; without load

from load voltage 2L+ (without load), max.

30 mA; without load

Encoder supply

 

Number of outputs

8; max. depending on parameterization

24 V encoder supply

 

  • в—Џ 24 V

Yes; L+ (-0.8 V)

  • в—Џ Short-circuit protection

Yes

  • в—Џ Output current, max.

1.2 A; Total current of all encoders / channels, max. 0.5 A per output

Power

 

Power available from the backplane bus

1.3 W

Power loss

 

Power loss, typ.

5 W

Address area

 

Occupied address area

 

  • в—Џ Inputs

44 byte

  • в—Џ Outputs

74 byte

Digital inputs

 

Number of digital inputs

8; max. depending on parameterization

  • в—Џ in groups of

8

Digital inputs, parameterizable

Yes

Input characteristic curve in accordance with IEC 61131, type 3

Yes

Digital input functions, parameterizable

 

  • в—Џ Digital input with time stamp

Yes

  • — Number, max.

8

  • в—Џ Counter

Yes

  • — Number, max.

4

  • в—Џ Counter for incremental encoder

Yes

  • — Number, max.

4

  • в—Џ Digital input with oversampling

Yes

  • — Number, max.

8

  • в—Џ HW enable for digital input

Yes

  • — Number, max.

4

  • в—Џ HW enable for digital output

Yes

  • — Number, max.

4

Input voltage

 

  • в—Џ Type of input voltage

DC

  • в—Џ Rated value (DC)

24 V

  • в—Џ for signal "0"

-30 to +5V

  • в—Џ for signal "1"

+11 to +30V

  • в—Џ permissible voltage at input, min.

-30 V

  • в—Џ permissible voltage at input, max.

30 V

Input current

 

  • в—Џ for signal "1", typ.

2.5 mA

Input delay (for rated value of input voltage)

 

  • в—Џ Minimum pulse width for program reactions

3 µs for parameterization "none"

for standard inputs

 

  • — parameterizable

Yes; none / 0.05 / 0.1 / 0.4 / 0.8 ms

  • — at "0" to "1", min.

4 µs; for parameterization "none"

  • — at "1" to "0", min.

4 µs; for parameterization "none"

Cable length

 

  • в—Џ shielded, max.

1 000 m; Depending on sensor, cable quality and rate of change

  • в—Џ unshielded, max.

600 m; Depending on sensor, cable quality and rate of change

Digital outputs

 

Type of digital output

Transistor

Number of digital outputs

16; max. depending on parameterization

  • в—Џ in groups of

8

Current-sinking

Yes; With High Speed output

Current-sourcing

Yes

Digital outputs, parameterizable

Yes

Short-circuit protection

Yes; electronic/thermal

  • в—Џ Response threshold, typ.

1.7 A with Standard output, 0.5 A with High Speed output

Limitation of inductive shutdown voltage to

-0.8 V

Controlling a digital input

Yes

Digital output functions, parameterizable

 

  • в—Џ Digital output with time stamp

Yes

  • — Number, max.

16

  • в—Џ PWM output

Yes

  • — Number, max.

16

  • в—Џ Digital output with oversampling

Yes

  • — Number, max.

16

Switching capacity of the outputs

 

  • в—Џ with resistive load, max.

0.5 A; 0.1 A with High Speed output

  • в—Џ on lamp load, max.

5 W; 1 W with High Speed output

Load resistance range

 

  • в—Џ lower limit

48 в„¦; 240 ohm with High Speed output

  • в—Џ upper limit

12 kΩ

Output voltage

 

  • в—Џ Type of output voltage

DC

  • в—Џ for signal "0", max.

1 V; With High Speed output

  • в—Џ for signal "1", min.

23.2 V; L+ (-0.8 V)

Output current

 

  • в—Џ for signal "1" rated value

0.5 A; 0.1 A with High Speed output, observe derating

  • в—Џ for signal "1" permissible range, max.

0.6 A; 0.12 A with High Speed output, observe derating

  • в—Џ for signal "1" minimum load current

2 mA

  • в—Џ for signal "0" residual current, max.

0.5 mA

Output delay with resistive load

 

  • в—Џ "0" to "1", max.

1 µs; With High Speed output, 5 µs with Standard output

  • в—Џ "1" to "0", max.

1 µs; With High Speed output, 6 µs with Standard output

Switching frequency

 

  • в—Џ with resistive load, max.

10 kHz

  • в—Џ on lamp load, max.

10 Hz

Total current of the outputs

 

  • в—Џ Current per group, max.

4 A

  • в—Џ Current per module, max.

8 A; Observe derating

Cable length

 

  • в—Џ shielded, max.

1 000 m; Depending on load and cable quality

  • в—Џ unshielded, max.

600 m; Depending on load and cable quality

Encoder

 

Connectable encoders

 

  • в—Џ Incremental encoder (asymmetrical)

Yes

  • в—Џ 24 V initiator

Yes

  • в—Џ 2-wire sensor

Yes

  • — permissible quiescent current (2-wire sensor), max.

1.5 mA

Encoder signals, incremental encoder (asymmetrical)

 

  • в—Џ Input voltage

24 V

  • в—Џ Input frequency, max.

50 kHz

  • в—Џ Counting frequency, max.

200 kHz; with quadruple evaluation

  • в—Џ Cable length, shielded, max.

600 m; Depending on input frequency, encoder and cable quality; max. 200 m at 50 kHz

  • в—Џ Incremental encoder with A/B tracks, 90° phase offset

Yes

  • в—Џ Pulse encoder

Yes

Encoder signal 24 V

 

  • — permissible voltage at input, min.

-30 V

  • — permissible voltage at input, max.

30 V

Interface types

 

  • в—Џ Input characteristic curve in accordance with IEC 61131, type 3

Yes

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes

Bus cycle time (TDP), min.

250 µs

Jitter, max.

1 µs

Interrupts/diagnostics/status information

 

Diagnostics function

Yes

Substitute values connectable

Yes

Alarms

 

  • в—Џ Diagnostic alarm

Yes

Diagnostic messages

 

  • в—Џ Monitoring the supply voltage

Yes

  • в—Џ Short-circuit

Yes

Diagnostics indication LED

 

  • в—Џ RUN LED

Yes; Green LED

  • в—Џ ERROR LED

Yes; Red LED

  • в—Џ MAINT LED

Yes; yellow LED

  • в—Џ Monitoring of the supply voltage (PWR-LED)

Yes; Green LED

  • в—Џ Channel status display

Yes; Green LED

  • в—Џ for channel diagnostics

Yes; Red LED

Integrated Functions

 

Number of counters

4

Counting frequency (counter) max.

200 kHz; with quadruple evaluation

Counting functions

 

  • в—Џ Continuous counting

Yes

Potential separation

 

Potential separation channels

 

  • в—Џ between the channels and backplane bus

Yes

Isolation

 

Isolation tested with

707 V DC (type test)

Ambient conditions

 

Ambient temperature during operation

 

  • в—Џ horizontal installation, min.

0 °C

  • в—Џ horizontal installation, max.

60 °C

  • в—Џ vertical installation, min.

0 °C

  • в—Џ vertical installation, max.

40 °C; Observe derating

Decentralized operation

 

to SIMATIC S7-1500

Yes

Dimensions

 

Width

35 mm

Height

147 mm

Depth

129 mm

Weights

 

Weight, approx.

320 g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2018
Siemens Industry Catalog Drive technology Automation technology Automation systems SIMATIC Industrial Automation Systems Controllers I/O systems SIMATIC ET 200 systems for the control cabinet SIMATIC ET 200SP SIMATIC ET 200MP Interface modules SIPLUS interface modules I/O modules Digital modules Analog modules Technology modules TM Count 2x24V counter module TM PosInput 2 counting and position detection module Time-based IO module TM Timer DIDQ 16x24V Interface module for PTO (Pulse Train Output) TM PTO 4 SIPLUS technology modules Communication Connection system F digital/analog modules Power supplies Accessories SIMATIC ET 200S SIMATIC ET 200M SIMATIC ET 200iSP SIMATIC ET 200 systems without control cabinet IO systems for heating elements PROFIBUS components PROFINET components Network components for PROFIBUS Network transitions SIMATIC control systems Software for SIMATIC Controllers Programming devices Siemens Partner Programm SIMOTION Motion Control System SINUMERIK CNC automation systems System cabling/control cabinets Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика