- 4-channel interface module for PTO (Pulse Train Output)
- 3 signal interfaces can be configured for speed and direction:
- 24 V asymmetrical up to 200 kHz
- RS422, 5 V symmetrical up to 1 MHz
- TTL 5 V asymmetrical up to 200 kHz
- 3 signal types can be configured:
- Pulse and direction
- Pulses for forward movement and pulses for backwards movement
- 2 phase-shifted signals, with simple or quadruple evaluation
- Supported technology objects:
- Speed controlled axis (S7-1500, S7-1500T)
- Positioning axis (S7-1200, S7-1500, S7-1500T)
- Synchronous axis (S7-1500, S7-1500T)
- Probe (S7-1500, S7-1500T)
|
|