General information | | | |
Product type designation | IM 155-6 PN ST with BA 2xRJ45 and server module | IM 155-6 PN HF | IM 155-6 DP HF |
Vendor identification (VendorID) | 002AH | | |
Device identifier (DeviceID) | 0313H | | |
Product function | | | |
| | Yes; I&M0 to I&M4 | Yes; I&M0 to I&M3 |
Engineering with | | | |
| | | V5.5 SP3 / - |
| | | GSD as of Revision 5 |
Configuration control | | | |
via dataset | | Yes | |
Supply voltage | | | |
Type of supply voltage | DC | | DC |
Rated value (DC) | | 24 V | 24 V |
permissible range, lower limit (DC) | 19.2 V | 19.2 V | 19.2 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V |
Reverse polarity protection | | Yes | Yes |
Mains buffering | | | |
| | 5 ms | 5 ms |
Input current | | | |
Current consumption, max. | | 700 mA | 250 mA |
Inrush current, max. | | 4.5 A | 4.5 A |
IІt | | 0.09 AІ·s | |
Power loss | | | |
Power loss, typ. | 1.9 W | 2.4 W | 1.5 W |
Address area | | | |
Address space per module | | | |
| | 288 byte; For input and output data respectively | |
Address space per station | | | |
| | 1 440 byte; Dependent on configuration | 244 byte |
Hardware configuration | | | |
Rack | | | |
| | 64; + 16 ET 200AL modules | |
Submodules | | | |
| | 256 | |
Interfaces | | | |
Number of PROFINET interfaces | | 1; 2 ports (switch) | |
Number of PROFIBUS interfaces | | | 1 |
1. Interface | | | |
Interface types | | | |
| | 2 | |
| | Yes | |
| | | Yes |
| | Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ (from FS03, V2.2), BA SCRJ / RJ45 (from FS03, V3.1), BA SCRJ / FC (from FS03, V3.1), BA 2x LC (from FS03, V3.3), BA LC / RJ45 (from FS03, V3.3), BA LC / FC (from FS03, V3.3) | |
| | | 90 mA |
Functionality | | | |
| | Yes | |
| | | Yes |
| | Yes | |
| | Yes; PROFINET MRP | |
Interface types | | | |
RJ 45 (Ethernet) | | | |
| | PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| | No | |
| | Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX) | |
| | Yes | |
| | Yes | |
RS 485 | | | |
| | | 12 Mbit/s |
PROFINET IO Device | | | |
Services | | | |
| | Yes; Bus cycle time: min. 250 µs | |
| | Yes | |
| | Yes; 250 Ојs, 500 Ојs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame | |
| | Yes | |
| | No | |
| | Yes; NAP S2 | |
| | Yes | |
| | Yes | |
| | Yes | |
| | 4 | |
Open IE communication | | | |
| Yes | Yes | |
| | Yes | |
| | Yes | |
PROFIBUS DP | | | |
Services | | | |
| | | Yes |
| | | Yes |
| | | No |
| | | Yes |
Isochronous mode | | | |
Isochronous operation (application synchronized up to terminal) | | Yes | |
Equidistance | | Yes | |
shortest clock pulse | | 250 µs | |
max. cycle | | 4 ms | |
Bus cycle time (TDP), min. | | 250 µs | |
Jitter, max. | | 1 µs | |
Interrupts/diagnostics/status information | | | |
Status indicator | | Yes | Yes |
Alarms | Yes | Yes | Yes |
Diagnostic functions | Yes | Yes | Yes |
Diagnostics indication LED | | | |
| | Yes; Green LED | Yes; Green LED |
| | Yes; Red LED | Yes; Red LED |
| | Yes; yellow LED | Yes; yellow LED |
| | Yes; green PWR LED | Yes; green PWR LED |
| | Yes; 2x green link LEDs on BusAdapter | |
| | | Yes; Green DP LED |
Potential separation | | | |
between backplane bus and electronics | | No | |
between PROFIBUS DP and all other circuit components | | | Yes |
between PROFINET and all other circuits | | Yes | |
between supply and all other circuits | | Yes | Yes |
Permissible potential difference | | | |
between different circuits | 75 V DC/60 V AC | | 75 V DC/60 V AC (base isolation) |
Isolation | | | |
Isolation tested with | 707 V DC between supply voltage and electronics; 1 500 V AC between Ethernet and electronics | | 707 V DC (type test) |
Standards, approvals, certificates | | | |
Network loading class | | 3 | |
Security level | | According to Security Level 1 Test Cases V1.1.1 | |
Ambient conditions | | | |
Ambient temperature during operation | | | |
| -40 °C; = Tmin; Startup @ -25 °C | -40 °C; = Tmin; Startup @ -25 °C | -40 °C; = Tmin; Startup @ -25 °C |
| 70 °C; = Tmax | 60 °C; = Tmax | 70 °C; = Tmax |
| -40 °C; = Tmin; Startup @ -25 °C | 0 °C | -40 °C; = Tmin; Startup @ -25 °C |
| 50 °C; = Tmax | 50 °C | 50 °C; = Tmax |
Altitude during operation relating to sea level | | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | | |
| 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
Use in stationary industrial systems | | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Connection method | | | |
ET-Connection | | | |
| | Yes; + 16 ET 200AL modules | |
Dimensions | | | |
Width | 50 mm | 50 mm | 50 mm |
Height | 117 mm | 117 mm | 117 mm |
Depth | 74 mm | 74 mm | 74 mm |
Weights | | | |
Weight, approx. | | 147 g; without BusAdapter | 150 g |