Input | |
Flow range | ± 12 m/s (± 40 ft/s), bi-directional |
Flow sensitivity | 0.0003 m/s (0.001 ft/s) flow rate independent |
Digital Inputs | |
Totalizer Hold | Optically isolated diode Input voltage: 2 … 10 V DC |
Totalizer Reset | Opticall isolated diode Input voltage: 2 … 10 V DC |
Output | |
Current | - 4 ... 20 mA (Isolated)
- externally powered 10 … 30 V DC
|
Relay | - Programmable Form C 250 mA
- 30 V DC
- 3 VA max
|
Pulse1) | - Optically isolated transistor 10 mA
- 30 V DC max
|
Accuracy | |
Accuracy | For velocities ≥ 0.3 m/s (1 ft/s) |
| ± 1.0 % of flow |
| ± 0.5 % … 1.0 % of flow |
Batch repeatability | ± 0.15 % |
Zero Drift | 0.1 % of rate; 0.0003 m/s (0.001 ft/s) |
Data refresh rate | 5 Hz |
Rated operation conditions | |
Operating temperature | -10 … +50 °C (14 … +122 °F) |
Storage temperature | -20 … +60 °C (-4 … +140 °F) |
Degree of protection | IP65/NEMA 4X |
Design | |
Weight | 1,4 kg (3.0 lbs) |
Dimensions (W x H x D) | 175 x 235 x 92 mm (6.89 x 9.25 x 3.62 inch) |
Enclosure material | Polycarbonate |
Power supply | 100 ... 240 V AC @ 20 VA or 11.5 ... 28.5 V DC @ 10 W |
Certificates and approvals | |
Unclassified locations | UL, ULc |
Classified locations | |
CE | EMC Directive 2014/30/EU ATEX Directive 2014/34/EU |
C-TICK | |