System information and selection guideSITRANS F US Clamp-on meters | FUS 1010 (Standard) | FST020 (Basic) | FUP 1010 (Portable) | FUE 1010 (Energy) | FUH 1010 (Oil) | FUG 1010 (Gas) | FUT 1010 (Liquid/Gas) |
|---|
Industry/Applications | Water and aqueous solutions | X | X | X | X | | | | Utility district heating, cooling | X | X | X | X | | | | Chemical | X | X | X | | | | | Hydrocarbons/Petrochemical, multiple products or varying viscosity, liquefied gases, net and gross volume | | | | | X | | X | Hydrocarbons (Single product with limited viscosity range) gross volume | X | | X | | X | | X | Very low flow < 0.1 m/s in small pipes | X | X | X | | | | | Natural gas | | | | | | X | X | Process gas | | | | | | X | X | Slurries or liquids with high percentage of un-dissolved gases | X | | X | X | | | | High temperature liquids > 120 °C (248 °F) | X1) | X1) | X1) | X1) | X1) | | | Refrigeration liquids | X | X | X | X | | | | Food products | X | X | X | | | | | Design | Field clamp-on (non-intrusive) | X | X | X | X | X | X | X | Doppler (Reflexor) hybrid capability | X | | X | X | | | | Standard volume or mass flow; per API 2540 | | | | | X | | X | Interface detection | | | | | X | | X | Density output | | | | | X | | X | Standard volume or mass flow; per AGA 8 | | | | | | X | X | Differential temperature w/ energy calculation | | | | X | | | | Temperature measurement | X | | X | X | X | X | X | Analog input | X | | X | X | X | X | X | Large graphics display | X | | X | X | X | X | X | Diagnostic PC software (Si-Ware) | X | X | X | X | X | X | X | Number of acoustic paths and channels | 1-channel | X | X | X | X | X | X | X | 2-path | X | | X | | X | X | X | 2-channel w/ arithmetic function | X | | X | X | | | | 4-path/(special order) | X | | | | X | X | X | 4-channel w/sum of active channels | X | | | | | | | Transmitter enclosure | IP65 (NEMA 4X) wall mount | X | X | | X | X | X | X | IP67 weatherproof | | | X | | | | | IP40 (NEMA 1) portable | | | | X2) | | | | IP66 (NEMA 7) walll mount explosionproof | X | | | | X | X | X | 1) Special order high temperature clamp-on sensor 2) Available with portable energy systems |
SITRANS F US Clamp-on meters | FUS 1010 (Standard) | FST020 (Basic) | FUP 1010 (Portable) | FUE 1010 (Energy) | FUH 1010 (Oil) | FUG 1010 (Gas) | FUT 1010 (Liquid/Gas) |
|---|
Power Supply | Internal battery operation | | | X | X1) | | | | Battery charger (100 ... 240 V AC 50 ... 60 Hz) with country specific line cord | | | X | X1) | | | | 90 ... 240 V AC 50 ... 60 Hz | X | X | | X | X | X | X | 9 ... 36 V DC | X | X | | X | X | X | X | Size (For larger pipes, see spares list for appropriate sensors and mountings) | | 6.5 ... 9 150 mm (0.25“ ... 360.24“) | X | X | X | | | | | 38 ... 1 370 mm (1.5“ ... 54“) | | | | X | X | X | | Approvals | FM/CSA2)4) | X | | | X3) | X | X | X | ATEX4) | X | | | | X | X | X | UL/ULc4) | | X | X | X | | | | C-TICK4) | X | X | | X | X | X | | 1) Available with portable energy systems 2) NEMA 4X associated equipment in DIV 2 connected to DIV 1 sensors, NEMA 7 explosionproof equipment in DIV 1 connected to DIV 1 sensors. 3) Not for portable enclosure 4) Products are marked with CE as required by european directive. |
Sensor type selection guide| | Standard sensors supported in MLFB | |
|---|
Application condition. Note all that apply before making selection | High precision | Universal | Reflexor | Notes | Media | | | | | General survey (clean liquids) on non-steel pipes | | X | O | | General survey (clean liquids) on a limited range of steel pipes | X | | O | | Moderately aerated liquid or slurry, up to 121 °C (250 °F) | X | | | | Highly aerated liquid or slurry | O | O | X | | Permanent installation on steel pipe (clean liquids) | X | | O | | Installation in offshore or corrosive environment | O | X1) | O | Sensors available with corrosion resistance as special order | Liquid temperature greater than 120 °C (248 °F) | O | X1) | | High temp metal block sensors available as special order (to 230 °C (446 °F)) | Operation on single pipeline flowing multiple products | X | O | | | Natural gas or process gas | X | O | O | Consult sales specialist for all gas applications | Pipe material | | | | | Steel | X | | O | | Steel pipe with diameter/wall thickness ratio < 10 | O | X | | | Non-steel pipe material (copper, ductile iron, cast iron, etc.) | O | X | | High precision sensors can also be used on plastic and aluminum pipes | Wall thickness > 31.75 mm (1.25“) | O | X | | | O = not suitable | | | | X = preferred choice | | | | 1) Available for special order | | | |
DefinitionsSensor Chart | Description |
|---|
Standard | Standard system sensor, plastic body with alu housing, FM, CE | Spare | Available for special application and special pipes. Contact factory for application use. Not available as part of a configured product | Gas | Usable for gas application. Available also as corrosion resistant, frame, track or weldseal mounting, T1, T2. FM, ATEX, CE | CE | All flowmeter and sensors are CE - certified | Ex-FM | Clamp-On sensors available as: Standard or corrosion resistant, suitable for frames or SS-frames mounting, T1, T2 or T3 | Ex-ATEX | Option for all corrosion resistant, frames, weldseal, T1, T2, T3 | Corrosion Resistant | Stainless steel housing instead Alu | Trackless | Fixed only by straps, no other mounting (spacer bar as an option) | Tracks | Portable and dedicated for universal size A/B and for HP size A/B. For all size HT only dedicated | Frames | Portable and dedicated for universal size C,D,E, and for HP size C/D. For universal and HP size B available for pipes >125 OD | Portable | BNC instead F-connector. Mounting universal sensor by portable tracks, frames and spacerbar | Transportable | Dedicated sensor including adapter for portable BNC cables. | WeldSeal | Special stainless steel frames for FUH1010, FUG1010, but also special FUS1010. Corrosion resistant, Liquid and Gas, T1, T2 | T1 | Usable -40 to 120°C, but best for Ø Temperature <40°C; Standard | T2 | Usable -40 to 120°C, but best for Ø Temperature >40°C - <80°C; Named as high temperature high precision | T3 | Usable -40 to 120°C, but best for Ø Temperature >80°C; special request | Submersible | Sensors can be used subersible by denso. |
Sensor Availability Guide| | Availability |
|---|
Sensor models | Standard | Spare only | Gas | Ex-ATEX | Ex-FM | Corrosion resistant | Trackless | Tracks | Frames | Universal Sensor -40 … 120 °C Alu Housing CE IP68 | A1 Universal for pipe OD – 5.8 … 50.8 mm (0.23” … 2”) | | X | | X1) | X1) | X1) | X3) | X | | A2 Universal for pipe OD – 12.7 … 50.8 mm (0.5” … 2”) | X | | | X1) | X1) | X1) | X3) | X | | B1 Universal for pipe OD – 12.7 … 76 mm (0.5” … 3”) | | X | | X1) | X1) | X1) | X3) | X | X | B2 Universal for pipe OD – 12.7 … 76 mm (0.5” … 3”) | | X | | X1) | X1) | X1) | X3) | X | X | B3 Universal for pipe OD – 19 … 127 mm (0.75” … 5”) | X | | | X1) | X1) | X1) | X3) | X | X | C1 Universal for pipe OD – 51 … 254 mm (2” … 10”) | | X | | X1) | X1) | X1) | X | | X | C2 Universal for pipe OD – 51 … 254 mm (2” … 10”) | | X | | X1) | X1) | X1) | X | | X | C3 Universal for pipe OD – 51 … 305 mm (2” … 12”) | X | | | X1) | X1) | X1) | X | | X | D1 Universal for pipe OD – 102 … 508 mm (4” … 20”) | | X | | X1) | X1) | X1) | X | | X | D2 Universal for pipe OD – 152 … 610 mm (6” … 24”) | | X | | X1) | X1) | X1) | X | | X | D3 Universal for pipe OD – 203 … 610 mm (8” … 24”) | X | | | X1) | X1) | X1) | X | | X | *E1 Universal for pipe OD – 254 … 3048 mm (10” … 120”) | | X | | X1) | X1) | X1) | X | | X | *E2 Universal for pipe OD – 254 … 6096 mm (10” … 240”) | X | | | X1) | X1) | X1) | X | | X | *E3 Universal for pipe OD – 304 … 9144 mm (12” … 360”) | | X | X1) | X1) | X1) | X1) | X | | X | 1) Excluding portable 2) Spare Only 3) Useable but not recommended |
| | Availability |
|---|
Sensor models | Portable | Transportable | High Precision Mount | T1 (best use -40 … 65 °C) | T2 (best use 1 … 104 °C) | T3 (best use 32 … 120 °C) | Submersible | Cataloge | Universal Sensor -40 … 120 °C Alu Housing CE IP68 | A1 Universal for pipe OD – 5.8 … 50.8 mm (0.23” … 2”) | X | | | | | | X1) | | A2 Universal for pipe OD – 12.7 … 50.8 mm (0.5” … 2”) | X | | | | | | X1) 2) | X | B1 Universal for pipe OD – 12.7 … 76 mm (0.5” … 3”) | X | | | | | | X1) | | B2 Universal for pipe OD – 12.7 … 76 mm (0.5” … 3”) | X | | | | | | X1) | | B3 Universal for pipe OD – 19 … 127 mm (0.75” … 5”) | X | | | | | | X1) 2) | X | C1 Universal for pipe OD – 51 … 254 mm (2” … 10”) | X | | | | | | X1) | | C2 Universal for pipe OD – 51 … 254 mm (2” … 10”) | X | | | | | | X1) | | C3 Universal for pipe OD – 51 … 305 mm (2” … 12”) | X | | | | | | X1) 2) | X | D1 Universal for pipe OD – 102 … 508 mm (4” … 20”) | X | | | | | | X1) | | D2 Universal for pipe OD – 152 … 610 mm (6” … 24”) | X | | | | | | X1) | | D3 Universal for pipe OD – 203 … 610 mm (8” … 24”) | X | | | | | | X1) 2) | X | * E1 Universal for pipe OD – 254 … 3048 mm (10” … 120”) | X | | | | | | X1) | | * E2 Universal for pipe OD – 254 … 6096 mm (10” … 240”) | X | | | | | | X1) 2) | X | * E3 Universal for pipe OD – 304 … 9144 mm (12” … 360”) | X | | X1) | | | | X1) | | 1) Excluding portable 2) Spare Only 3) Useable but not recommended |
| | Availability |
|---|
Sensor models | Standard | Spare only | Gas | Ex-ATEX | Ex-FM | Corrosion resistant | Trackless | Tracks | Frames | High Precision Sensor -40 … 120 °C Alu T1 (T2, T3) CE | A1H (High Precision) for pipe WT - 0.64 ... 1.0 mm (0.025" ... 0.04") | | X | X1) | X1) | X1) | X1) | X3) | X | | A2H (High Precision) for pipe WT - 1.0 ... 1.5 mm (0.04" ... 0.06") | X | | X1) | X1) | X1) | X1) | X3) | X | | A3H (High Precision) for pipe WT - 1.5 ... 2.0 mm (0.06" ... 0.08") | X | | X1) | X1) | X1) | X1) | X3) | X | | B1H (High Precision) for pipe WT - 2.0 ... 3.0 mm (0.08" ... 0.12") | X | | X1) | X1) | X1) | X1) | X3) | X | X | B2H (High Precision) for pipe WT - 3.0 ... 4.1 mm (0.12" ... 0.16") | X | | X1) | X1) | X1) | X1) | X3) | X | X | B3H (High Precision) for pipe WT - 2.7 ... 3.3 mm (0.106" ... 0.128") | | X | X1) | X1) | X1) | X1) | X3) | X | X | C1H (High Precision) for pipe WT (stainless steel construction) - 4.1 ... 5.8 mm (0.16" ... 0.23") | X | | X1) | X1) | X1) | X1) | X | | X | C2H (High Precision) for pipe WT (stainless steel construction) - 5.8 ... 8.1 mm (0..23" ... 0.32") | X | | X1) | X1) | X1) | X1) | X | | X | * D1H (High Precision) for pipe WT (stainless steel construction) - 8.1 ... 11.2 mm (0..32" ... 0.44") | X | | X1) | X1) | X1) | X1) | X | | X | * D2H (High Precision) for pipe WT (stainless steel construction) - 11.2 ... 15.7 mm (0.44" ... 0.62") | X | | X1) | X1) | X1) | X1) | X | | X | * D3H (High Precision) for pipe WT (stainless steel construction) - 7.4 ... 9.0 mm (0..293" ... 0.354") | | X | X1) | X1) | X1) | X1) | X | | X | * D4H (High Precision) for pipe WT (stainless steel construction) - 15.7 ... 31.8 mm (0..62" ... 1.25") | X | | X1) | X1) | X1) | X1) | X | | X | High Temperature Universal Sensor -40 ... +230 °C | High Temperature size 1 ... 230 deg C (diam. 12.7 ... 100 mm) | | X | | X1) | X1) | | | X | | High Temperature size 2 ... 230 deg C (diam. 30 ... 200 mm ) | X | | | X1) | X1) | | | X | | High Temperaturer size 3 ... 230 deg C (diam. 150 ... 610 mm) | X | | | X1) | X1) | | | X | | High Temperature size 4 ... 230 deg C (diam. 400 ... 1200 mm) | X | | | X1) | X1) | | | X | | High Temperaturer size 2A4) ... 230 deg C (diam. 30 ... 200 mm) | | X | | X1) | X1) | | | X | | High Temp. size 3A4) ... 230 deg C (diam. 150 ... 610 mm) | | X | | X1) | X1) | | | X | | High Temp. size 4A4) ... 230 deg C (diam. 400 ... 1200 mm) | | X | | X1) | X1) | | | X | | Doppler Sensor | Doppler Sensor, for up to 121 °C (250 °F) | X | | | X1) | X1) | | X | | | Corrosion Resistant Doppler , for up to 121 °C (250 °F) | | X | | X1) | X1) | X1) | X | | | 1) Excluding portable 2) Spare Only 3) Useable but not recommended 4) High temperature size "xA" can be used in all applications but is better suited for DN pipes. Please use SiWare for selection. |
| | Availability |
|---|
Sensor models | Portable | Transportable | High Precision Mount | T1 (best use -40 … 65 °C) | T2 (best use 1 … 104 °C) | T3 (best use 32 … 120 °C) | Submersible | Cataloge | High Precision Sensor -40 … 120 °C Alu T1 (T2, T3) CE IP68 | A1H (High Precision) for pipe WT - 0.64 ... 1.0 mm (0.025" ... 0.04") | | X | | X | | | X1) | X | A2H (High Precision) for pipe WT - 1.0 ... 1.5 mm (0.04" ... 0.06") | | X | | X | | | X1) 2) | X | A3H (High Precision) for pipe WT - 1.5 ... 2.0 mm (0.06" ... 0.08") | | X | | X | | | X1) 2) | X | B1H (High Precision) for pipe WT - 2.0 ... 3.0 mm (0.08" ... 0.12") | | X | | X | X | X | X1) 2) | X | B2H (High Precision) for pipe WT - 3.0 ... 4.1 mm (0.12" ... 0.16") | | X | | X | X | X | X1) 2) | X | B3H (High Precision) for pipe WT - 2.7 ... 3.3 mm (0.106" ... 0.128") | | X | | X | X | X | X1) | X | C1H (High Precision) for pipe WT - 4.1 ... 5.8 mm (0.16" ... 0.23") | | X | X1) | X | X | X | X1) 2) | X | C2H (High Precision) for pipe WT (stainless steel construction) - 5.8 ... 8.1 mm (0..23" ... 0.32") | | X | X1) | X | X | X | X1) 2) | X | * D1H (High Precision) for pipe WT (stainless steel construction) - 8.1 ... 11.2 mm (0..32" ... 0.44") | | X | X1) | X | X | X | X1) 2) | X | * D2H (High Precision) for pipe WT (stainless steel construction) - 11.2 ... 15.7 mm (0.44" ... 0.62") | | X | X1) | X | X | X | X1) 2) | X | * D3H (High Precision) for pipe WT (stainless steel construction) - 7.4 ... 9.0 mm (0..293" ... 0.354") | | X | X1) | X | X | X | X1) | X | * D4H (High Precision) for pipe WT (stainless steel construction) - 15.7 ... 31.8 mm (0..62" ... 1.25") | | X | X1) | X | X | X | X1) 2) | X | High Temperature Universal Sensor -40 ... +230 °C | High Temperature size 1 ... 230 deg C (diam. 12.7 ... 100 mm) | | X | | | | | | | High Temperature size 2 ... 230 deg C (diam. 30 ... 200 mm ) | | X | | | | | | X | High Temperaturer size 3 ... 230 deg C (diam. 150 ... 610 mm) | | X | | | | | | X | High Temperature size 4 ... 230 deg C (diam. 400 ... 1200 mm) | | X | | | | | | X | High Temperaturer size 2A4) ... 230 deg C (diam. 30 ... 200 mm) | | X | | | | | | | High Temp. size 3A4) ... 230 deg C (diam. 150 ... 610 mm) | | X | | | | | | | High Temp. size 4A4) ... 230 deg C (diam. 400 ... 1200 mm) | | X | | | | | | | Doppler Sensor | Doppler Sensor | X | | | | | | X1) | X | Corrosion Resistant Doppler, | | | | | | | | | High Temperature Doppler | | | | | | | | | 1) Excluding portable 2) Spare Only 3) Useable but not recommended 4) High temperature size "xA" can be used in all applications but is better suited for DN pipes. Please use SiWare for selection. |
Sensor Mounting Availability Guide| | Sensor |
|---|
| | Universal dedicated | Universal portable | Dedicated gas and liquid flow HP-sensors | Portable liquid flow HP-sensors | High temperature universal sensors | Doppler dedicated | Doppler portable | Mounting | Trackless | X | X | X | X | | X | X | Tracks universal dedicated | X | X1) | | | | | | Tracks universal portable | X1) | X | | | | | | Tracks HP dedicated | | | X | X1) | | | | Tracks HP portalbe | | | X1) | X | | | | Frames universal dedicated | X | X1) | | | | | | Frames universal portable | X1) | X | | | | | | Frames HP dedicated | | | X | X1) | | | | Frames HP portable | | | X1) | X | | | | Tracks high temp universal | | | | | X | | | WeldSeal single enclosure | | | X | | | | | WeldSeal dual enclosure | | | X | | | | | SpacerBar | X | X | X | X | | | | Straps | X | X1) | X | X1) | X | X | X1) | Chains tension hook | | X | | X | | | | Chains EZ-Clamp 1 | Size C, D | Size C, D | Size C | Size C | | | | Chains EZ-Clamp 2 | Size E | Size E | Size D | Size D | | | | Denso | X | | X | | | X | | Doppler Chains | | | | | | | X | 1) Useable but not recommended |
Input/output and function availability guide| | | | | | | Output |
|---|
| | | | Standard | Additional Inputs | Expanded/Enhanced | 4 … 20 mA active | 4 … 20 mA passive | FUS1010 | NEMA 4X and NEMA 7 wall mount | Single channel | X | | | 2 | | X | X | | 2 | | Dual channel | X | | | 23) | | X | X | | 23) | | | | | X | 23) | 44) | Dual path | X | | | 2 | | X | X | | 2 | | | | | X | 2 | 4 | Four path | X | | | | 43) | X | X | | | 43) | Four path | X | | | | 4 | X | X | | | 4 | FST020 | NEMA 4X wall mount | Single channel | X | | | | 1 | FUP1010 | IP67 | Single channel | | X | | | 1 | Dual channel/path | | X | | | 23) | FUE1010 | NEMA 4X | Single channel | X | X | | 2 | | Dual channel | X | X | | 23) | | | | X | X | 23) | | Dual path | X | X | | 2 | | | | X | X | 2 | 4 | NEMA 1 portable | Dual channel/path | X | X | | | 23) | FUH1010 | NEMA 4X and NEMA 7 wall mount | Single channel | X | X | | 2 | | Dual path | X | X | | 2 | | | | X | X2) | 2 | 2 | Four path2) | | X | X | 2 | 2 | FUG1010 | NEMA 4X and NEMA 4 wall mount | Single channel | X | X | | 2 | | Dual path | | X | X | 2 | 2 | Four path | | X | X | 2 | 2 | 1) Fixed to IO adjustment 2) Not available for Interface Detector 3) One per channel 4) Two per channel |
| | | | Output |
|---|
| | | | 0 … 10 V | 0 … 5 kHz | p-gen (20 … 40 kHz) | Relay – Dry reed | Status Alarm | FUS1010 | NEMA4X and NEMA 7 wall mount | Single channel | 2 | 2 | | 4 | | 2 | 2 | | 4 | | Dual channel | 2 | 2 | | 44) | | 2 | 2 | | 44) | | 2 | 2 | | 44) | | Dual path | 2 | 2 | | 4 | | 2 | 2 | | 4 | | 2 | 2 | | 4 | | Four channel | 43) 1) | | | 4 | | 43) 1) | | | 43) | | Four path | 41) | | | 43) | | 41) | | | 4 | | FST020 | NEMA 4X wall mount | Single channel | | 1 | | | 1 | FUP1010 | IP67 | Single channel | 1 | 1 | | | 2 | Dual channel/path | 23) | 23) | | | 44) | FUE1010 | NEMA 4X | Single channel | 2 | 2 | | 4 | | Dual channel | 23) | 23) | | | | 23) | 23) | | 44) | | Dual path | 2 | 2 | | 4 | | 2 | 2 | | 4 | | NEMA 1 portable | Dual channel/path | 23) | 23) | | | 44) | FUH1010 | NEMA 4X and NEMA 7 wall mount | Single channel | 2 | 2 | | 4 | | Dual path | 2 | | 2 | 4 | | 2 | | 2 | 4 | | Four path2) | 2 | | 2 | 4 | | FUG1010 | NEMA 4X and NEMA 7 wall mount | Single channel | 2 | | 2 | 4 | | Dual path | 2 | | 2 | 4 | | Four path | 2 | | 2 | 4 | | 1) Fixed to IC adjustment 2) Not available for Interface Detector 3) One per channel 4) Two per channel |
| | | | Input |
|---|
| | | | 4 … 20 mA passive | 0 … 10 V | 1000 Ohm RTD | NoTot | ClrTot | FUS1010 | NEMA 4X and NEMA 7 wall mount | Single channel | | | | 1 | 1 | 4 | | 1 | 1 | 1 | Dual channel | | | | 2 | 2 | 44) | | 2 | 2 | 2 | | | | | 2 | 2 | Dual path | | | | 1 | 1 | 4 | | 1 | 1 | 1 | | | | | 1 | 1 | Four channel | | | | 4 | | 4 | | 1 | 4 | | Four path | | | | 4 | | 4 | | 1 | 4 | | FST020 | NEMA 4X wall mount | Single channel | | | | | | FUP1010 | IP67 | Single channel | | | | | | Dual channel/path | | | | | | FUE1010 | NEMA 4X | Single channel | 4 | | 2 | 1 | 1 | Dual channel | 23) | | 4 | 2 | 2 | 23) | | 4 | 2 | 2 | Dual path | 2 | | 4 | 1 | 1 | 2 | | 4 | 1 | 1 | NEMA 1 portable | Dual channel/path | 2 | | 4 | 2 | 2 | FUH1010 | NEMA 4X and NEMA 7 wall mount | Single channel | | | 1 | 1 | 1 | Dual path | 2 | | 1 | 1 | 1 | 2 | | 1 | 1 | 1 | Four path2) | 2 | | 1 | 1 | 1 | FUG1010 | NEMA 4X and NEMA 7 wall mount | Single channel | | | 1 | 1 | 1 | Dual path | 2 | | 1 | 1 | 1 | Four path | 2 | | 1 | 1 | 1 | 1) Fixed to IC adjustment 2) Not available for Interface Detector 3) One per channel 4) Two per channel |
| | ATEX | Unimass | Modbus | Doppler |
|---|
FUS1010 | NEMA4X and NEMA 7 wall mount | Single channel | X | | X | X | X | X | X | X | Dual channel | X | | X | X | X | 2 | X | X | X | | X | X | Dual path | X | | X | X | X | 1 | X | X | X | | X | X | Four channel | X | | X | | X | 4 | X | | Four path | X | | X | | X | 1 | X | | FST020 | NEMA 4X wall mount | Single channel | | | | | FUP1010 | IP67 | Single channel | | | | X | Dual channel/path | | | | X | FUE1010 | NEMA 4X | Single channel | FM | | X | X | Dual channel | FM | | X | X | FM | | X | X | Dual path | FM | | X | X | FM | | X | X | NEMA 1 portable | Dual channel/path | | | | X | FUH1010 | NEMA 4X and NEMA 7 wall mount | Single channel | X | | X | | Dual path | X | | X | | X | | X | | Four path2) | X | | X | | FUG1010 | NEMA 4X and NEMA 7 wall mount | Single channel | X | | X | | Dual path | X | | X | | Four path | X | | X | | 1) Fixed to IC adjustment 2) Not available for Interface Detector 3) One per channel 4) Two per channel |
|
|