Article number

6ES7416-2FP07-0AB0

6ES7416-3FS07-0AB0

CPU 416F-2, MPI, PROFIBUS, 8 MB

CPU416F-3 PN/DP, 16 MB, 3 INTERFACES

General information

Product type designation

CPU 416F-2

CPU 416F-3 PN/DP

HW functional status

01

01

Firmware version

V7.0

V7.0

Engineering with

  • Programming package

STEP 7 V5.4 or higher with HSP 261

STEP 7 V5.5 or higher with HSP 262

CiR Configuration in RUN

CiR synchronization time, basic load

100ms

100ms

CiR synchronization time, time per I/O byte

10s

10s

Supply voltage

Rated value (DC)

  • 24 V DC

No; Power supply via system power supply

No; Power supply via system power supply

Input current

from backplane bus 5 V DC, typ.

0.9A

1.3A

from backplane bus 5 V DC, max.

1.1A

1.6A

from backplane bus 24 V DC, max.

300mA; 150 mA per DP interface

300mA; 150 mA per DP interface

from interface 5 V DC, max.

90mA; At each DP interface

90mA; At each DP interface

Power loss

Power loss, typ.

4.5W

6.5W

Power loss, max.

5.5W

8W

Memory

Type of memory

RAM

RAM

Work memory

  • integrated

8Mbyte

16Mbyte

  • integrated (for program)

4Mbyte

8Mbyte

  • integrated (for data)

4Mbyte

8Mbyte

  • expandable

No

No

Load memory

  • expandable FEPROM

Yes; with Memory Card (FLASH)

Yes; with Memory Card (FLASH)

  • expandable FEPROM, max.

64Mbyte

64Mbyte

  • integrated RAM, max.

1Mbyte

1Mbyte

  • expandable RAM

Yes; with Memory Card (RAM)

Yes; with Memory Card (RAM)

  • expandable RAM, max.

64Mbyte

64Mbyte

Backup

  • present

Yes

Yes

  • with battery

Yes; all data

Yes; all data

  • without battery

No

No

Battery

Backup battery

  • Backup current, typ.

180A; up to 40 C

180A; up to 40 C

  • Backup current, max.

850A

850A

  • Backup time, max.

Dealt with in the module data manual with the secondary conditions and the factors of influence

Dealt with in the module data manual with the secondary conditions and the factors of influence

  • Feeding of external backup voltage to CPU

5 V DC to 15 V DC

5 V DC to 15 V DC

CPU processing times

for bit operations, typ.

12.5ns

12.5ns

for word operations, typ.

12.5ns

12.5ns

for fixed point arithmetic, typ.

12.5ns

12.5ns

for floating point arithmetic, typ.

25ns

25ns

CPU-blocks

DB

  • Number, max.

10000; Number range: 1 to 16000

10000; Number range: 1 to 16000

  • Size, max.

64kbyte

64kbyte

FB

  • Number, max.

5000; Number range: 0 to 7999

5000; Number range: 0 to 7999

  • Size, max.

64kbyte

64kbyte

FC

  • Number, max.

5000; Number range: 0 to 7999

5000; Number range: 0 to 7999

  • Size, max.

64kbyte

64kbyte

OB

  • Number, max.

see instruction list

see instruction list

  • Size, max.

64kbyte

64kbyte

  • Number of free cycle OBs

1; OB 1

1; OB 1

  • Number of time alarm OBs

8; OB 10-17

8; OB 10-17

  • Number of delay alarm OBs

4; OB 20-23

4; OB 20-23

  • Number of cyclic interrupt OBs

9; OB 30-38 (shortest cycle that can be set = 500 s)

9; OB 30-38 (shortest cycle that can be set = 500 s)

  • Number of process alarm OBs

8; OB 40-47

8; OB 40-47

  • Number of DPV1 alarm OBs

3; OB 55-57

3; OB 55-57

  • Number of isochronous mode OBs

4; OB 61-64

4; OB 61-64

  • Number of multicomputing OBs

1; OB 60

1; OB 60

  • Number of background OBs

1; OB 90

1; OB 90

  • Number of startup OBs

2; OB 100, 102

2; OB 100, 102

  • Number of asynchronous error OBs

9; OB 80-88

9; OB 80-88

  • Number of synchronous error OBs

2; OB 121, 122

2; OB 121, 122

Nesting depth

  • per priority class

24

24

  • additional within an error OB

2

2

Counters, timers and their retentivity

S7 counter

  • Number

2048

2048

Retentivity

  • adjustable

Yes

Yes

  • lower limit

0

0

  • upper limit

2047

2047

  • preset

Z 0 to Z 7

Z 0 to Z 7

Counting range

  • lower limit

0

0

  • upper limit

999

999

IEC counter

  • Number

Unlimited (limited only by RAM capacity)

Unlimited (limited only by RAM capacity)

S7 times

  • Number

2048

2048

Retentivity

  • adjustable

Yes

Yes

  • lower limit

0

0

  • upper limit

2047

2047

  • preset

No times retentive

No times retentive

Time range

  • lower limit

10ms

10ms

  • upper limit

9990s

9990s

IEC timer

  • present

Yes

Yes

  • Type

SFB

SFB

  • Number

Unlimited (limited only by RAM capacity)

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total

Total working and load memory (with backup battery)

Total working and load memory (with backup battery)

Flag

  • Number, max.

16kbyte; Size of bit memory address area

16kbyte; Size of bit memory address area

  • Retentivity available

Yes

Yes

  • Retentivity preset

MB 0 to MB 15

MB 0 to MB 15

  • Number of clock memories

8; in 1 memory byte

8; in 1 memory byte

Data blocks

  • Number, max.

10000; Number range: 1 to 16000

10000; Number range: 1 to 16000

  • Size, max.

64kbyte

64kbyte

Local data

  • adjustable, max.

32kbyte

32kbyte

  • preset

16kbyte

16kbyte

Address area

I/O address area

  • Inputs

16kbyte

16kbyte

  • Outputs

16kbyte

16kbyte

of which distributed

  • MPI/DP interface, inputs

2kbyte

2kbyte

  • MPI/DP interface, outputs

2kbyte

2kbyte

  • DP interface, inputs

8kbyte

8kbyte

  • DP interface, outputs

8kbyte

8kbyte

  • PROFINET interface, inputs

8kbyte

  • PROFINET interface, outputs

8kbyte

Process image

  • Inputs, adjustable

16kbyte

16kbyte

  • Outputs, adjustable

16kbyte

16kbyte

  • Inputs, default

512byte

512byte

  • Outputs, default

512byte

512byte

  • consistent data, max.

244byte

244byte

  • Access to consistent data in process image

Yes

Yes

Subprocess images

  • Number of subprocess images, max.

15

15

Digital channels

  • Inputs

131072

131072

  • of which central

131072

131072

  • Outputs

131072

131072

  • of which central

131072

131072

  • Number of addressable digital I/Os, max.

131072; Inputs and outputs in each case

131072; Inputs and outputs in each case

Analog channels

  • Inputs

8192

8192

  • of which central

8192

8192

  • Outputs

8192

8192

  • of which central

8192

8192

  • Number of addressable analog I/Os, max.

8192; Inputs and outputs in each case

8192; Inputs and outputs in each case

Hardware configuration

Number of expansion units, max.

21

21

connectable OPs

95

95

Multicomputing

Yes; 4 CPUs max. (with UR1 or UR2)

Yes; 4 CPUs max. (with UR1 or UR2)

Interface modules

  • Number of connectable IMs (total), max.

6

6

  • Number of connectable IM 460s, max.

6

6

  • Number of connectable IM 463s, max.

4; IM 463-2

4; IM 463-2

Number of DP masters

  • integrated

2

1

  • via CP

10; CP 443-5 Extended

10; CP 443-5 Extended

  • via IM 467

4

4

  • Mixed mode IM + CP permitted

No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode

No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode

  • via interface module

0

1; IF 964-DP

  • Number of pluggable S5 modules (via adapter capsule in central device), max.

6

6

Number of IO Controllers

  • integrated

0

1

  • via CP

4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode

4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode

Number of operable FMs and CPs (recommended)

  • FM

Limited by number of slots and number of connections

Limited by number of slots or number of connections

  • CP, PtP

CP 440: Limited by number of slots; CP 441: limited by number of connections

CP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections

  • PROFIBUS and Ethernet CPs

14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller

14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller

Slots

  • required slots

1

2

Time of day

Clock

  • Hardware clock (real-time)

Yes

Yes

  • retentive and synchronizable

Yes

Yes

  • Resolution

1ms

1ms

  • Deviation per day (buffered), max.

1.7s; Power off

1.7s; Power off

  • Deviation per day (unbuffered), max.

8.6s; For power On

8.6s; For power On

Operating hours counter

  • Number

16

16

  • Number/Number range

0 to 15

0 to 15

  • Range of values

SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours

SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours

  • Granularity

1 hour

1 hour

  • retentive

Yes

Yes

Clock synchronization

  • supported

Yes

Yes

  • to MPI, master

Yes

Yes

  • to MPI, slave

Yes

Yes

  • to DP, master

Yes

Yes

  • to DP, slave

Yes

Yes

  • in AS, master

Yes

Yes

  • in AS, slave

Yes

Yes

  • on Ethernet via NTP

No; Via CP

Yes; As client

  • to IF 964 DP

No

Yes

Time difference in system when synchronizing via

  • Ethernet, max.

10ms

  • MPI, max.

200ms

200ms

Interfaces

Interfaces/bus type

1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP

1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports), 1 x PROFIBUS DP (optionally pluggable)

Number of RS 485 interfaces

2; Combined MPI / PROFIBUS DP and PROFIBUS DP

1; Combined MPI / PROFIBUS DP

Number of other interfaces

1; PROFIBUS DP with IF 964-DP (plug-in option; MLFB: 6ES7964-2AA04-0AB0)

1. Interface

Interface type

Integrated

Integrated

Physics

RS 485 / PROFIBUS + MPI

RS 485 / PROFIBUS + MPI

Isolated

Yes

Yes

Power supply to interface (15 to 30 V DC), max.

150mA

150mA

Number of connection resources

MPI: 44, DP: 32

MPI: 44, DP: 32

Functionality

  • MPI

Yes

Yes

  • PROFIBUS DP master

Yes

Yes

  • PROFIBUS DP slave

Yes

Yes

MPI

  • Number of connections

44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

  • Transmission rate, max.

12Mbit/s

12Mbit/s

Services

  • PG/OP communication

Yes

Yes

  • Routing

Yes

Yes

  • Global data communication

Yes

Yes

  • S7 basic communication

Yes

Yes

  • S7 communication

Yes

Yes

  • S7 communication, as client

Yes

Yes

  • S7 communication, as server

Yes

Yes

DP master

  • Number of connections, max.

32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1

  • Transmission rate, max.

12Mbit/s

12Mbit/s

  • Number of DP slaves, max.

32

32

Services

  • PG/OP communication

Yes

Yes

  • Routing

Yes; S7 routing

Yes; S7 routing

  • Global data communication

No

No

  • S7 basic communication

Yes

Yes

  • S7 communication

Yes

Yes

  • S7 communication, as client

Yes

Yes

  • S7 communication, as server

Yes

Yes

  • Equidistance

Yes

Yes

  • Isochronous mode

Yes

Yes

  • SYNC/FREEZE

Yes

Yes

  • Activation/deactivation of DP slaves

Yes

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

Yes

  • DPV1

Yes

Yes

Address area

  • Inputs, max.

2kbyte

2kbyte

  • Outputs, max.

2kbyte

2kbyte

User data per DP slave

  • User data per DP slave, max.

244byte

244byte

  • Inputs, max.

244byte

244byte

  • Outputs, max.

244byte

244byte

  • Slots, max.

244

244

  • per slot, max.

128byte

128byte

DP slave

  • Number of connections

32

32

  • GSD file

http://support.automation.siemens.com/WW/view/en/113652

http://support.automation.siemens.com/WW/view/en/113652

  • Transmission rate, max.

12Mbit/s

12Mbit/s

  • automatic baud rate search

No

No

  • Address area, max.

32; Virtual slots

32; Virtual slots

  • User data per address area, max.

32byte

32byte

  • of which consistent, max.

32byte

32byte

Services

  • PG/OP communication

Yes; with interface active

Yes; with interface active

  • S7 routing

Yes; with interface active

Yes; with interface active

  • Global data communication

No

No

  • S7 basic communication

No

No

  • S7 communication

Yes

Yes

  • S7 communication, as client

Yes

Yes

  • S7 communication, as server

Yes

Yes

  • Direct data exchange (slave-to-slave communication)

No

No

  • DPV1

No

No

Transfer memory

  • Inputs

244byte

244byte

  • Outputs

244byte

244byte

2. Interface

Interface type

Integrated

PROFINET

Physics

RS 485 / PROFIBUS

Ethernet RJ45

Isolated

Yes

Yes

Power supply to interface (15 to 30 V DC), max.

150mA

automatic detection of transmission rate

Yes; Autosensing

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime, supported

Yes; Assignment by higher-level IO-Controller or by the user program with SFB104 "IP_CONF"

Number of connection resources

32

96

Interface types

  • Number of ports

2

  • integrated switch

Yes

Media redundancy

  • supported

Yes

  • Switchover time on line break, typ.

200ms

  • Number of stations in the ring, max.

50

Functionality

  • PROFINET IO Controller

Yes

  • PROFINET IO Device

Yes

  • PROFINET CBA

Yes

  • PROFIBUS DP master

Yes

No

  • PROFIBUS DP slave

Yes

No

  • Open IE communication

Yes

  • Web server

Yes

  • Number of HTTP clients

5

  • Point-to-point connection

No

DP master

  • Number of connections, max.

32

  • Transmission rate, max.

12Mbit/s

  • Number of DP slaves, max.

125

Services

  • PG/OP communication

Yes

  • Routing

Yes; S7 routing

  • Global data communication

No

  • S7 basic communication

Yes

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Equidistance

Yes

  • Isochronous mode

Yes

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV1

Yes

Address area

  • Inputs, max.

8kbyte

  • Outputs, max.

8kbyte

User data per DP slave

  • User data per DP slave, max.

244byte

  • Inputs, max.

244byte

  • Outputs, max.

244byte

  • Slots, max.

244

  • per slot, max.

128byte

DP slave

  • Number of connections

32

  • GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • Transmission rate, max.

12Mbit/s

  • Address area, max.

32

  • User data per address area, max.

32byte

  • of which consistent, max.

32byte

Services

  • Routing

Yes; with interface active

Transfer memory

  • Inputs

244byte

  • Outputs

244byte

PROFINET IO Controller

  • Transmission rate, max.

100Mbit/s

Services

  • PG/OP communication

Yes

  • S7 routing

Yes

  • S7 communication

Yes

  • Isochronous mode

Yes; Only with IRT and the High Performance option

  • Open IE communication

Yes

  • Shared device

Yes

  • Prioritized startup

Yes

  • Number of IO devices with prioritized startup, max.

32

  • Number of connectable IO Devices, max.

256

  • Of which IO devices with IRT, max.

64

  • of which in line, max.

64

  • Number of IO Devices with IRT and the option "high flexibility"

256

  • of which in line, max.

61

  • Number of connectable IO Devices for RT, max.

256

  • of which in line, max.

256

  • Activation/deactivation of IO Devices

Yes

  • Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • IO Devices changing during operation (partner ports), supported

Yes

  • Number of IO Devices per tool, max.

8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation (partner ports) are supported

  • Device replacement without swap medium

Yes

  • Send cycles

250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 s to 4 ms in 125 s frame

  • Updating time

250 s to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description

Address area

  • Inputs, max.

8kbyte

  • Outputs, max.

8kbyte

  • User data consistency, max.

1024byte

PROFINET IO Device

Services

  • PG/OP communication

Yes

  • S7 routing

Yes

  • S7 communication

Yes

  • Isochronous mode

No

  • Open IE communication

Yes

  • IRT

Yes

  • Prioritized startup

Yes

  • Shared device

Yes

  • Number of IO Controllers with shared device, max.

2

Transfer memory

  • Inputs, max.

1440byte; Per IO Controller with shared device

  • Outputs, max.

1440byte; Per IO Controller with shared device

Submodules

  • Number, max.

64

  • User data per submodule, max.

1024byte

PROFINET CBA

  • acyclic transmission

Yes

  • cyclic transmission

Yes

Open IE communication

  • Number of connections, max.

94

  • Local port numbers used at the system end

0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535

  • Keep-alive function, supported

Yes

3. Interface

Interface type

Pluggable interface module (IF)

Plug-in interface modules

IF 964-DP (MLFB: 6ES7964-2AA04-0AB0)

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

150mA

automatic detection of transmission rate

No

Number of connection resources

32

Functionality

  • MPI

No

  • PROFIBUS DP master

Yes

  • PROFIBUS DP slave

Yes

DP master

  • Number of connections, max.

32

  • Number of DP slaves, max.

125

Services

  • PG/OP communication

Yes

  • Routing

Yes; S7 routing

  • Global data communication

No

  • S7 basic communication

Yes

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Equidistance

Yes

  • Isochronous mode

Yes

  • SYNC/FREEZE

Yes

  • Activation/deactivation of DP slaves

Yes

  • Direct data exchange (slave-to-slave communication)

Yes

  • DPV0

Yes

  • DPV1

Yes

Address area

  • Inputs, max.

8kbyte

  • Outputs, max.

8kbyte

User data per DP slave

  • User data per DP slave, max.

244byte

  • Inputs, max.

244byte

  • Outputs, max.

244byte

  • Slots, max.

244

  • per slot, max.

128byte

DP slave

  • Number of connections

32

  • GSD file

http://support.automation.siemens.com/WW/view/en/113652

  • Transmission rate, max.

12Mbit/s

  • automatic baud rate search

No

  • Address area, max.

32; Virtual slots

  • User data per address area, max.

32byte

  • of which consistent, max.

32byte

Services

  • PG/OP communication

Yes

  • S7 routing

Yes; with interface active

  • Global data communication

No

  • S7 basic communication

No

  • S7 communication

Yes

  • S7 communication, as client

Yes

  • S7 communication, as server

Yes

  • Direct data exchange (slave-to-slave communication)

No

  • DPV1

No

Transfer memory

  • Inputs

244byte

  • Outputs

244byte

Open IE communication

  • TCP/IP

Yes; via integrated PROFINET interface and loadable FBs

  • Data length, max.

32kbyte

  • several passive connections per port, supported

Yes

  • ISO-on-TCP (RFC1006)

Via CP 443-1 and loadable FB

Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs

  • Data length, max.

1452 bytes via CP 443-1 Adv.

32kbyte; 1452 bytes via CP 443-1 Adv.

  • UDP

Yes; via integrated PROFINET interface and loadable FBs

  • Data length, max.

1472byte

Web server

  • User-defined websites

Yes

  • Number of HTTP clients

5

Isochronous mode

Isochronous operation (application synchronized up to terminal)

Yes; For PROFIBUS only

Yes; Via PROFIBUS DP or PROFINET interface

Equidistance

Yes

Yes

Number of DP masters with isochronous mode

2

2

User data per isochronous slave, max.

244byte

244byte

shortest clock pulse

1ms; 0.5 ms without use of SFC 126, 127

1ms; 0.5 ms without use of SFC 126, 127

max. cycle

32ms

32ms

Communication functions

PG/OP communication

Yes

Yes

  • Number of connectable OPs without message processing

95

95

  • Number of connectable OPs with message processing

95; When using Alarm_S/SQ and Alarm_D/DQ

95; When using Alarm_S/SQ and Alarm_D/DQ

Data record routing

Yes

Yes

Global data communication

  • supported

Yes

Yes

  • Number of GD loops, max.

16

16

  • Number of GD packets, transmitter, max.

16

16

  • Number of GD packets, receiver, max.

32

32

  • Size of GD packets, max.

54byte

54byte

  • Size of GD packet (of which consistent), max.

1 variable

1 variable

S7 basic communication

  • supported

Yes

Yes

  • User data per job, max.

76byte

76byte

  • User data per job (of which consistent), max.

1 variable

1 variable

S7 communication

  • supported

Yes

Yes

  • as server

Yes

Yes

  • as client

Yes

Yes

  • User data per job, max.

64kbyte

64kbyte

  • User data per job (of which consistent), max.

462byte; 1 variable

462byte; 1 variable

S5 compatible communication

  • supported

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5

  • User data per job, max.

8kbyte

8kbyte

  • User data per job (of which consistent), max.

240byte

240byte

  • Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.

64/64

64/64

Standard communication (FMS)

  • supported

Yes; Via CP and loadable FB

Yes; Via CP and loadable FB

Web server

  • supported

No

Yes

PROFINET CBA (at set setpoint communication load)

  • Setpoint for the CPU communication load

20%

  • Number of remote interconnection partners

32

  • Number of functions, master/slave

150

  • Total of all master/slave connections

6000

  • Data length of all incoming connections master/slave, max.

65000byte

  • Data length of all outgoing connections master/slave, max.

65000byte

  • Number of device-internal and PROFIBUS interconnections

1000

  • Data length of device-internal und PROFIBUS interconnections, max.

16000byte

  • Data length per connection, max.

2000byte

Remote interconnections with acyclic transmission

  • Sampling frequency: Sampling time, min.

200ms; Depending on preset communication load, number of interconnections and data length used

  • Number of incoming interconnections

500

  • Number of outgoing interconnections

500

  • Data length of all incoming interconnections, max.

16000byte

  • Data length of all outgoing interconnections, max.

16000byte

  • Data length per connection, max.

2000byte

Remote interconnections with cyclic transmission

  • Transmission frequency: Transmission interval, min.

1ms; Depending on preset communication load, number of interconnections and data length used

  • Number of incoming interconnections

300

  • Number of outgoing interconnections

300

  • Data length of all incoming interconnections, max.

4800byte

  • Data length of all outgoing interconnections, max.

4800byte

  • Data length per connection, max.

450byte

HMI variables via PROFINET (acyclic)

  • Number of stations that can log on for HMI variables (PN OPC/iMap)

2x PN OPC/1x iMap

  • HMI variable updating

500ms

  • Number of HMI variables

1500

  • Data length of all HMI variables, max.

48000byte

PROFIBUS proxy functionality

  • supported

Yes; 32 PROFIBUS slaves max. connectable

  • Data length per connection, max.

240byte; Slave-dependent

Number of connections

  • overall

96

96

  • usable for PG communication

95

95

  • reserved for PG communication

1

1

  • adjustable for PG communication, max.

0

0

  • usable for OP communication

95

95

  • reserved for OP communication

1

1

  • adjustable for OP communication, max.

0

0

  • usable for S7 basic communication

94

94

  • reserved for S7 basic communication

0

0

  • adjustable for S7 basic communication, max.

0

0

  • usable for S7 communication

94

94

  • reserved for S7 communication

0

0

  • adjustable for S7 communication, max.

0

0

  • usable for routing

47

47

  • reserved for routing

0

0

  • adjustable for routing, max.

0

0

S7 message functions

Number of login stations for message functions, max.

95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)

95; Max. 95 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)

Symbol-related messages

Yes

Yes

SCAN procedure

Yes

Yes

Program alarms

Yes

Yes

Process diagnostic messages

Yes

Yes

simultaneously active Alarm-S blocks, max.

1000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks

1000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks

Alarm 8-blocks

Yes

Yes

  • Number of instances for alarm 8 and S7 communication blocks, max.

4000

4000

  • preset, max.

600

600

Process control messages

Yes

Yes

Number of archives that can log on simultaneously (SFB 37 AR_SEND)

32

32

Number of messages

  • overall, max.

1024

1024

  • in 100 ms grid, max.

128

128

  • in 500 ms grid, max.

512

512

  • in 1000 ms grid, max.

1024

1024

Number of additional values

  • with 100 ms grid, max.

1

1

  • with 500, 1000 ms grid, max.

10

10

Test commissioning functions

Status block

Yes; Up to 16 simultaneously

Yes; Up to 16 simultaneously

Single step

Yes

Yes

Number of breakpoints

16

16

Status/control

  • Status/control variable

Yes; Up to 16 variable tables

Yes; Up to 16 variable tables

  • Variables

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters

  • Number of variables, max.

70; Status/control

70; Status/control

Forcing

  • Forcing

Yes

Yes

  • Forcing, variables

Inputs, outputs, bit memories, peripheral inputs, peripheral outputs

Inputs/outputs, bit memories, distributed I/Os

  • Number of variables, max.

512

512

Diagnostic buffer

  • present

Yes

Yes

  • Number of entries, max.

3200

3200

  • adjustable

Yes

Yes

  • preset

120

120

Service data

  • can be read out

Yes

Yes

Standards, approvals, certificates

CE mark

Yes

Yes

CSA approval

Yes

Yes

UL approval

Yes

Yes

cULus

Yes

Yes

FM approval

Yes

Yes

RCM (formerly C-TICK)

Yes

Yes

KC approval

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Use in hazardous areas

  • ATEX

ATEX II 3G Ex nA IIC T4 Gc

ATEX II 3G Ex nA IIC T4 Gc

Ambient conditions

Ambient temperature during operation

  • min.

0C

0C

  • max.

60C

60C

Configuration

Configuration software

  • STEP 7

Yes

Yes

Programming

  • Command set

see instruction list

see instruction list

  • Nesting levels

7

7

  • Access to consistent data in process image

Yes

Yes

  • System functions (SFC)

see instruction list

see instruction list

  • System function blocks (SFB)

see instruction list

see instruction list

Programming language

  • LAD

Yes

Yes

  • FBD

Yes

Yes

  • STL

Yes

Yes

  • SCL

Yes

Yes

  • CFC

Yes

Yes

  • GRAPH

Yes

Yes

  • HiGraph

Yes

Yes

Number of simultaneously active SFCs

  • DPSYC_FR

2; SFC 11; per interface

2; SFC 11; per interface

  • D_ACT_DP

8; SFC 12; per interface

8; SFC 12; per interface

  • RD_REC

8; SFC 59; per interface

8; SFC 59; per interface

  • WR_REC

8; SFC 58; per interface

8; SFC 58; per interface

  • WR_PARM

8; SFC 55; per interface

8; SFC 55; per interface

  • PARM_MOD

1; SFC 57; per interface

1; SFC 57; per interface

  • WR_DPARM

2; SFC 56; per interface

2; SFC 56; per interface

  • DPNRM_DG

8; SFC 13; per interface

8; SFC 13; per interface

  • RDSYSST

8; SFC 51

8; SFC 51

  • DP_TOPOL

1; SFC 103; per interface

1; SFC 103; per interface

Number of simultaneously active SFBs

  • RDREC

8; SFB 52; per interface, but not more than 32 across all external interfaces

8; SFB 52; per interface, but not more than 32 across all external interfaces

  • WRREC

8; SFB 53; per interface, but not more than 32 across all external interfaces

8; SFB 53; per interface, but not more than 32 across all external interfaces

Know-how protection

  • User program protection/password protection

Yes

Yes

  • Block encryption

Yes; With S7 block Privacy

Yes; With S7 block Privacy

Dimensions

Width

25mm

50mm

Height

290mm

290mm

Depth

219mm

219mm

Weights

Weight, approx.

700g

900g


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS -

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK -
2018
Siemens Industry Catalog Drive technology Automation technology Automation systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Introduction Industrial Ethernet PROFINET Introduction Drive systems Controllers Modular controllers SIMATIC S7-1200 SIMATIC S7-1500 SIMATIC S7-300 SIMATIC S7-400 Central processing units Standard CPUs Fail-safe CPUs CPU 414F CPU 416F High-availability CPUs Distributed controllers PC-based controllers Embedded Controllers Embedded bundles Communication for SIMATIC S7-1500 System interfaces / SIMATIC S7 / Communication for SIMATIC S7-300 System interfaces / SIMATIC S7 / Communication for SIMATIC S7-400 System interfaces for PG/PC/IPC / Communication for PC-based systems SIMATIC PCS 7 process control systems Distributed I/O Motion control systems CNC controls Operator panels Industrial PC Switching and protection devices for power distribution Power Monitoring SENTRON measuring devices Configuring, Visualizing and Controlling with SIMATIC Configuring, Visualizing and Controlling with SENTRON Industrial identification systems Network components Industrial controls SITOP power supplies Software and tools Network management and diagnostics Technology components PROFIBUS AS-Interface IO-Link Industrial wireless communication Industrial remote communication Industrial security Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.