General information | |
Ambient temperature | -30 ... 55 °C (with heating) |
Explosion protection | Set CV is comprised of components with individual approvals according to ATEX 2G. Before local installation, general approval from an audit authority is required. This service is not included in delivery. |
Supply voltage | 230 V AC, 115 V AC or 24 V DC |
Max. permissible pressure at input of high-pressure reduction | 16 000 kPa |
Max. permissible pressure at input of sample preparation system with pressure regulator | 16 000 kPa |
Max. permissible pressure at output of sample preparation system | 10 … 60 kPa above atmospheric pressure Notice: Only the measurements < 1.3 Vol. % acetylene are permissible. |
Sampling | |
Lance | Outer diameter 6 mm and inner diameter 2 mm or outer diameter 12 mm and inner diameter 8 mm Length 1 000 mm |
Special probe with BTU diaphragm and pressure reduction, non-retractable | - Immersion depth approx. 380 mm
- Protection pipe outer diameter 25.4 mm
|
Process connection | - At flange DN 65 PN 16 form C,
max. 1 600 kPa gas pressure - At flange DN 65 PN 160 form E,
max. 16 000 kPa gas pressure - At flange ANSI, 2-inch, 300 lbs RF
- At flange ANSI, 2-inch, 2 500 lbs RF
|
High-pressure reduction in casing with pressure regulators, optional heating | - Casing with dimensions 385 x 485 x 380 mm
- Primary pressure 16 000 kPa, output pressure 100/170 kPa (power consumption 150 W)
|
Pipe base | 2-inch pipe base for free-standing transmitter box, 1 700 mm high |
Heated line | - Heating power is 38 W/m
- Self-regulating heating up to approximately 80 °C
- Outer material is PE corrugated hose with 43 mm outer diameter
|
Sample preparation | For 1 to 3 sample gas flow, plus calibration gas flow |
Basic configuration | 0.5 µm filter, 3/2-way solenoid valve, flowmeter, overflow valve and stopcock |
Pressure regulator, optional heating | Primary pressure 16 000 kPa, output pressure 100/170 kPa (power consumption 150 W) |
Simple sample injection | One 3/2-way solenoid valve per sample gas stream |
DB&B sample injection | Two 3/2-way solenoid valves per sample gas flow |
Material in contact with the calibration gas | SS316 (pipe material and fittings) |
On mounting plate | 682 x 482 x 3 mm |
In protective casing | 800 x 600 x 480 mm |
Protective casing heating | Power consumption 300 W adjustable between 10 and 40 °C, in increments of 5. |
Pipe base | 2-inch pipe base, 1 700 mm high |
Additional filters | Aerosol, glycol |
System components | |
On mounting plate | 650 x 422 x 3 mm |
In protective casing | 750 x 520 x 430 mm |
Protective casing heating | Power consumption 400 W adjustable between 10 and 40 °C, in increments of 5. |
Terminal box | 340 x 170 x 91 mm |
Pipe base | 2-inch pipe base, 1700 mm high |
Heated line | - Heating power is 38 W/m
- Self-regulating heating up to approximately 80 °C
- Outer material is PE corrugated hose with 43 mm outer diameter
|
Gas supply | |
Transfer station | Max. cylinder pressure 20 000 kPa Output pressure 50 ... 1 000 kPa |
Pipe base | 2-inch pipe base, mounted Height 2 200 mm |
Gas cylinder cabinet | Gas cylinder cabinet for two 50‑l carrier gas cylinders and one 10‑l calibration gas cylinder. The dimensions are 1 250 x 400 x 2 050 mm. |
Cylinder heating | The cylinder heating system is dimensioned for 10 l calibration gas cylinders and ensures that no condensation occurs within the gas cylinder. |
Cylinder pressure reducer | Cylinder pressure reducer for reducing primary pressure of max. 30 000 kPa to back pressure 0 … 400 kPa |
Heated line | - Heating power is 38 W/m
- Self-regulating heating up to approximately 80 °C
- Outer material is PE corrugated hose with 43 mm outer diameter
|
Calibration gas | |
Gas mixture 1 ... 6 | The gas mixture is stable for 36 months. |