Suitability for use | Hybrid cable for connection of ECOFAST stations | Hybrid cable for connection of ECOFAST stations, UL approval |
Cable designation | 02Y (ST)C 1 x 2 x 0.65/2.56 - 150 LI LIH-Z 11Y 4 x 1 x 1.5 VI FRNC | 02Y (ST)C 1x2x0.65/2.56 -150 LI LIY-Z Y 4x1x1.5 VI |
Electrical data | | |
Damping ratio per length | | |
| 4dB/km | 4dB/km |
| 4dB/km | 4dB/km |
| 25dB/km | 25dB/km |
| 49dB/km | 49dB/km |
Impedance | | |
| 150Ω | 150Ω |
| 270Ω | 270Ω |
| 185Ω | 185Ω |
| 150Ω | 150Ω |
Relative symmetrical tolerance | | |
| 10% | 10% |
| 10% | 10% |
| 10% | 10% |
Loop resistance per length maximum | 138Ω/km | 138Ω/km |
Shield resistance per length maximum | 15Ω/km | 15Ω/km |
Insulation resistance coefficient | 20GΩm | 20GΩm |
Operating voltage maximum | 80V | 80V |
Capacity per length at 1 kHz | 30pF/m | 30pF/m |
Operating voltage RMS value | 100V | 600V |
Conductor cross section of the power wire | 1.5mm | 1.5mm |
Continuous current of the power wires | 12A | 12A |
Mechanical data | | |
Design of the shield | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires | Overlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires |
Number of electrical cores | 6 | 6 |
Type of electrical connection FastConnect | No | No |
Outer diameter | | |
| 0.67mm | 0.67mm |
| 2.56mm | 2.56mm |
| 11mm | 11mm |
Symmetrical tolerance of the outer diameter of cable sheath | 0.3mm | 0.3mm |
Material | | |
| PE | PE |
| PUR | PVC |
Color | | |
| red / green | red / green |
| Black | Black |
| Violet | Violet |
Bending radius | | |
| 82.5mm | 110mm |
Number of bending cycles | 5000000; For use in cable carriers, for 5 million bending cycles with a bending radius of 82.5 mm (7.5x D) and an acceleration of 2.5 m/s | 1000000; For use in cable carriers, for 1 million bending cycles with a bending radius of 166 mm (15x D) and an acceleration of 4.0 m/s |
Tensile load maximum | 300N | 300N |
Weight per length | 150kg/km | 154kg/km |
Permitted ambient conditions | | |
Ambient temperature | | |
| -40...+60C | -30...+80C |
| -40...+60C | -30...+80C |
| -40...+60C | -30...+80C |
| -40...+60C | -30...+80C |
| Electrical properties measured at 20 Cel, verification according to DIN 47250 part 4 respectively DIN VDE 0472 | Electrical properties measured at 20 Cel, verification according to DIN 47250 part 4 respectively DIN VDE 0472 |
Burning behavior | flame-retardant according to IEC 60332-1 | flame-retardant according to IEC 60332-3-24 (Category C) |
Chemical resistance | | |
| Conditional resistance | Conditional resistance |
| Conditional resistance | Conditional resistance |
Radiological resistance to UV radiation | resistant | resistant |
Product properties, functions, components general | | |
Product feature | | |
| Yes | Yes |
| Yes | Yes |
Standards, specifications, approvals | | |
UL/ETL listing 300 V Rating | No | No |
UL/ETL style 600 V Rating | No | Yes; CM / CL3 / SunRes / OilRes |
Certificate of suitability | | |
| Yes | Yes |