Article number

6GK1160-4AA01

6GK1160-4AT01

Product type designation

CP 1604

CP 1604 EEC

Transmission rate

 

 

Transfer rate

100 Mbit/s

100 Mbit/s

Interfaces

 

 

Number of electrical connections

 

 

  • в—Џ at the 1st interface acc. to Industrial Ethernet

4

4

  • в—Џ for power supply

1

1

Type of electrical connection

 

 

  • в—Џ at the 1st interface acc. to Industrial Ethernet

RJ45 port via connection board

RJ45 port via connection board

  • в—Џ for power supply

4-pole terminal block through power supply board

4-pole terminal block through power supply board

Supply voltage, current consumption, power loss

 

 

Type of voltage of the supply voltage

DC

DC

Type of voltage supply optional external supply

Yes

Yes

Supply voltage

 

 

  • в—Џ 1 from backplane bus

5 V

5 V

  • в—Џ external

5 V

  • в—Џ Note

optional external power supply and external supply voltage alternatively via power supply board (optional accessory)

Relative symmetrical tolerance at DC

 

 

  • в—Џ at 5 V

5 %

5 %

Consumed current

 

 

  • в—Џ 1 from backplane bus at DC maximum

0.8 A

0.8 A

  • в—Џ from external supply voltage at DC at 24 V maximum

0.3 A

Power loss [W]

4 W

4 W

Power loss [W] in switch mode maximum

4.1 W

4.1 W

Permitted ambient conditions

 

 

Ambient temperature

 

 

  • в—Џ during operation

5 ... 60 °C

-40 ... +70 °C

  • в—Џ during storage

-20 ... +60 °C

-20 ... +60 °C

  • в—Џ during transport

-20 ... +60 °C

-20 ... +60 °C

Relative humidity at 25 °C without condensation during operation maximum

95 %

95 %

Protection class IP

IP00

IP00

Design, dimensions and weight

 

 

Module format

PC/104-Plus

PC/104-Plus

Width

90 mm

90 mm

Height

24 mm

24 mm

Depth

95 mm

95 mm

Net weight

110 g

110 g

Mounting type

Screw mounting

Screw mounting

Number of plug-in cards of same design plug-in per PC station

1

1

Number of units Note

-

-

Performance data

 

 

Performance data PROFINET communication as PN IO-Controller

 

 

Software for PROFINET IO communication required

No

No

Number of PN IO devices on PROFINET IO controller usable total

128

128

Number of PN IO IRT devices on PROFINET IO controller usable

64

64

Amount of data

 

 

  • в—Џ as user data for input variables as PROFINET IO controller maximum

8 192 byte

8 192 byte

  • в—Џ as user data for input variables as PROFINET IO controller maximum

8 192 byte

8 192 byte

  • в—Џ as user data for input variables per PN IO device as PROFINET IO controller maximum

1 430 byte

1 430 byte

  • в—Џ as user data for output variables per PN IO device as PROFINET IO controller maximum

1 430 byte

1 430 byte

Performance data PROFINET communication as PN IO-Device

 

 

Amount of data

 

 

  • в—Џ as user data for input variables as PROFINET IO device maximum

1 430 byte

1 430 byte

  • в—Џ as user data for input variables as PROFINET IO device maximum

1 430 byte

1 430 byte

  • в—Џ as user data for input variables for each sub-module as PROFINET IO device

254 byte

254 byte

  • в—Џ as user data for input variables for each sub-module as PROFINET IO device

254 byte

254 byte

  • в—Џ as user data for the consistency area for each sub-module

254 byte

254 byte

Number of submodules per PROFINET IO-Device

64

64

Product functions management, configuration

 

 

Product function MIB support

Yes

Yes

Protocol is supported

 

 

  • в—Џ SNMP v1

Yes

Yes

  • в—Џ DCP

Yes

Yes

  • в—Џ LLDP

Yes

Yes

Configuration software required

Included in scope of supply

Included in scope of supply

Identification & maintenance function

 

 

  • в—Џ I&M0 - device-specific information

Yes

Yes

  • в—Џ I&M1 – higher-level designation/location designation

Yes

Yes

  • в—Џ I&M2 - installation date

Yes

Yes

  • в—Џ I&M3 - comment

Yes

Yes

  • в—Џ I&M4 - signature

Yes

Yes

  • в—Џ I&M4 - OEM data

Yes

Yes

Product functions Diagnosis

 

 

Product function

 

 

  • в—Џ Web-based diagnostics

Yes

Yes

  • в—Џ Port diagnostics

Yes

Yes

Product functions switch

 

 

Product feature Switch

Yes

Yes

Product function switch-managed

No

No

Product function with IRT PROFINET IO switch

Yes

Yes

Product functions Redundancy

 

 

Software for redundancy function required

No

No

Product function

 

 

  • в—Џ Ring redundancy

Yes

Yes

  • в—Џ Redundancy manager

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Standards, specifications, approvals

 

 

Standard

 

 

  • в—Џ for EMC

2004/108/EC

2004/108/EC

  • в—Џ for safety from CSA and UL

CAN/CSA C22.2 & UL 60950-1

CAN/CSA C22.2 & UL 60950-1

  • в—Џ for emitted interference

EN 61000-6-3, EN 61000-6-4

EN 61000-6-3, EN 61000-6-4

  • в—Џ for interference immunity

EN 61000-6-1, EN 61000-6-2

EN 61000-6-1, EN 61000-6-2

Certificate of suitability

 

 

  • в—Џ CE marking

Yes

Yes

  • в—Џ C-Tick

Yes

Yes

Accessories

 

 

accessories

optional: Connection board for CP 1604, power supply board for CP 1604, HARDNET-IE DK (development kit)

optional: Connection board for CP 1604, power supply board for CP 1604, HARDNET-IE DK (development kit)


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2018
Siemens Industry Catalog Drive technology Automation technology Automation systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Introduction Industrial Ethernet PROFINET Introduction Drive systems Controllers Modular controllers PC-based controllers Embedded Controllers Embedded bundles Communication for SIMATIC S7-1500 System interfaces / SIMATIC S7 / Communication for SIMATIC S7-300 System interfaces / SIMATIC S7 / Communication for SIMATIC S7-400 System interfaces for PG/PC/IPC / Communication for PC-based systems CP 1604 CP 1616 CP 1626 CP 1612 A2 SOFTNET PN IO PN CBA OPC server SIMATIC PCS 7 process control systems Distributed I/O Motion control systems CNC controls Operator panels Industrial PC Switching and protection devices for power distribution Power Monitoring SENTRON measuring devices Configuring, Visualizing and Controlling with SIMATIC Configuring, Visualizing and Controlling with SENTRON Industrial identification systems Network components Industrial controls SITOP power supplies Software and tools Network management and diagnostics Technology components PROFIBUS AS-Interface IO-Link Industrial wireless communication Industrial remote communication Industrial security Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика