Coriolis flowmeters are generally suitable for measuring liquids and gases. The flow measurement is independent of changes in process conditions/parameters such as temperature, density, pressure, viscosity, conductivity and flow profile. Due to this versatility the meter is easy to install and use. The Coriolis flowmeter is recognized for its high accuracy over a wide turn-down ratio. The main applications of the Coriolis flowmeter can be found in all industries, such as: |
|---|
Chemical and pharma | Detergents, bulk chemicals, pharmaceuticals, acids, alkalis, filling and dosing | Food and beverage | Dairy products, beer, wine, softdrinks, °Plato/°Brix, fruit juices and pulps, bottling, CO2 dosing, CIP-liquids | Automotive | Fuel injection nozzle & pump testing, filling of AC units, engine consumption measurement, paint robots | Oil and gas | Filling of gas bottles, furnace control, CNG-dispensers, test separators, LPG, well-head water-cut monitoring | Water & waste water | Dosing of chemicals for water treatment |
| |
|---|
Please see Product selector http://www.pia-selector.automation.siemens.com on the Internet, since some constrains might be related to some of the features  |  |  |  |  |  |  |  |  |  |  |  |   | SITRANS FC430 | SITRANS FC410 | MASS 2100 DI 1.5 | MASS 2100 DI 3 to DI 15 | FC300 DN 4 | FCS200 DN 10 to DN 25 | MASS 6000 IP67 | MASS 6000 19” | MASS 6000 Ex d | SIFLOW FC070 Std/Ex CT | MASS 2100/ FC300 with FCT010 | MASS 2100/ FC300 with FCT030 | 7ME4613 7ME4623 7ME4713 | 7ME4611 7ME4621 7ME4711 | 7ME4100 | 7ME4100, 7ME4200, 7ME4210 | 7ME4400 | 7ME4500 | 7ME4110 | 7ME4110 | 7ME4110 | 7ME4120 | 7ME4811 | 7ME4813 | Design | Compact | X | X | | X | | | X | | X | | X3) | X3) | Remote | X | | X | X | X | X | X | X | X | X | X | X | Transmitter enclosure | Polyamide, IP67/NEMA 6 | | | | | | | X | | | | | | Noryl (SIMATIC S7-300), IP20/NEMA 2 | | | | | | | | | | X | | | Stainless steel IP67/NEMA 6 | | | | | | | | | X | | | | 19" rack IP20/NEMA 2 aluminum | | | | | | | | X | | | | | Back of panel IP20 aluminum | | | | | | | | X | | | | | Wall mounting IP65 ABS plastic | | | | | | | | X | | | | | Front of panel IP65 ABS plastic | | | | | | | | X | | | | | Aluminium IP67 | X | X | | | | | | | | | X | X | Communication | HART | X | | | | | | X | X | X | | | X | PROFIBUS PA | X | | | | | | X | X | X | | | X | PROFIBUS DP | X | | | | | | X | X | | | | X | MODBUS RTU/RS 485 | X | X | | | | | X | X | | X | X | X | MODBUS RTU/RS 232 | | | | | | | | | | X | | | FOUNDATION Fieldbus H1 | | | | | | | X | X | X | | | | DeviceNet | | | | | | | X | X | | | | | Supply voltage | 24 V DC | X | X | | | | | | | | X | X | X | 24 V AC/DC | | | | | | | X | X | X | | | | 115/230 V AC | X | | | | | | X | X | | | | X | Pipe size | DI 1.5 (1/16”) | | | X | | | | | | | | X | X | DI 3 (1/8”) | | | | X | | | | | | | X | X | DN 4 (1/6”) | | | | | X | | | | | | X | X | DI 6 (¼”) | | | | X | | | | | | | X | X | DN 10 (3/8”) | | | | | | X | | | | | | | DI 15 (½”) | | | | X | | | | | | | X | X | DN 15 (½”) | X | X | | | | X | | | | | | | DN 25 (1”) | X | X | | | | | | | | | | | DN 50 (2”) | X | X | | | | | | | | | | | DN 80 (3”) | X | X | | | | | | | | | | | DN 100 (4”) | X | X | | | | | | | | | | | DN 150 (6”) | X | X | | | | | | | | | | | Process connection norms and pressure | Pipe thread | NPT ANSI/ASME B.20.1; PN 100 | X | X | X | X | X | | | | | | X | X | NPT ANSI/ASME B.20.1; PN 350 | | | | | | X | | | | | | | VCO | X | X | | | | X | | | | | | | ISO 228/1; PN 100 | X | X | X | X | X | | | | | | X | X | Flange | EN 1092-1 PN 40 | X | X | | X | | | | | | | X | X | EN 1092-1 PN 100 | X | X | | X | | | | | | | X | X | EN 1092-1 PN 1606) | X | X | | | | | | | | | | | ANSI B 16.5 Class 150 | X | X | | X | | | | | | | X | X | ANSI B 16.5 Class 300 | X | X | | | | | | | | | | | ANSI B 16.5 Class 600 | X | X | | X | | | | | | | X | X | ANSI B 16.5 Class 9007) | X | X | | | | | | | | | | | Dairy | DIN 11851 PN 25 | X | X | | X | | | | | | | X | X | DIN 11851 PN 40 | X | X | | X | | | | | | | X | X | DIN 11864-1A | X | X | | | | | | | | | | | DIN 11864-2A | X | X | | | | | | | | | | | DIN 11864-3A | X | X | | | | | | | | | | | Clamp ISO 2852 PN 16 | X | X | | X | | | | | | | X | X | ISO 2853 PN 16 | X | X | | X | | | | | | | X | X | DIN 32676 Tri-Clamp | X | X | | | | | | | | | | | Others on request | X | X | X | X | X | | | | | | X | X | Pipe material | Stainless steel AISI 316L/1.4435 | X | X | X | X | X | | | | | | X | X | Stainless steel AISI 316Ti/1.4571 | | | | | | | | | | | | | Hastelloy C22/2.4602 | X | X | X | X | X | X5) | | | | | X | X | Hastelloy C4/2.4610 | | | | | | | | | | | | | With heating jacket | Internal U-tube | | | | X | | | | | | | X | X | External electric jacket | X | X | | | | | | | | | | | Pressure rating | PN 40 | X | X | | X | | | | | | | X | X | PN 100 | X | X | X | X | X | | | | | | X | X | PN 160 | X | X | | | | | | | | | X | X | PN 214 | | | | | | X | | | | | X | X | PN 350 | | | | | | X | | | | | X | X | High-pressure version2) | | | X | X | X | | | | | | X | X | Accuracy | Flow error ≤ 0.1 % of rate8) | X | X | X | X | X | | | | | | X | X | Flow error ≤ 0.5 % of rate8) | | | | | | X | | | | | | | Density error ≤ 0.0005 g/cm3 | X | X | | X | | | | | | | X | X | Density error ≤ 0.001 g/cm3 | X | X | X | | | | | | | | X | X | Density error ≤ 0.0015 g/cm3 | | | | X3) | X | | | | | | | | Cable glands | PG 13.5 | | | | | | | | X4) | | | | | ½” NPT | X | X | | | | | X | | | | X | X | M20 | X | X | | | | | X | | X | | X | X |
X = available 1) Not available for DN 150 sensor. 2) Please see technical specifications. 3) DI 3, DI 6 and DI 15 4) Only when mounted in enclosure. 5) Process connectors in AISI 316Ti/1.4571 6) Sensor pressure limited to 100 bar (AISI 316L) and 160 bar (Hastelloy C22) 7) Sensor pressure limited to 100 bar (AISI 316L) and 150 bar (Hastelloy C22) 8) For reference conditions: ISO 9104 and DIN/EN 29104. Increased error can be expected for gas mass flow measurement. | |
|---|
Please see Product selector http://www.pia-selector.automation.siemens.com on the Internet, since some constrains might be related to some of the features  |  |  |  |  |  |  |  |  |  |  |  |   | SITRANS FC430 | SITRANS FC410 | MASS 2100 DI 1.5 | MASS 2100 DI 3 to DI 15 | FC300 DN 4 | FCS200 DN 10 to DN 25 | MASS 6000 IP67 | MASS 6000 19” | MASS 6000 Ex d | SIFLOW FC070 Std/Ex CT | MASS 2100/ FC300 with FCT010 | MASS 2100/ FC300 with FCT030 | 7ME4613 7ME4623 7ME4713 | 7ME4611 7ME4621 7ME4711 | 7ME4100 | 7ME4100, 7ME4200, 7ME4210 | 7ME4400 | 7ME4500 | 7ME4110 | 7ME4110 | 7ME4110 | 7ME4120 | 7ME4811 | 7ME4813 | Approvals | Custody transfer | Compressed gaseous fuel measuring systems for vehicles - OIML R 139 | | | | | | X | | | | X9) | | | NTEP | X11) | | | | | X | | | | | | | Other media than water pattern approval - OIML R 117 | X11) | | | | | | | | | | | | Hazardous locations | | | ATEX | X | X | X | X | X | X | X | X | X | X3)4) | X | X | IECEx | X | X | | | | X | | | | X4) | X | X | EAC Ex | X | X | X | X | X | X | | X | X | X3)4) | | | FM | X11) | X11) | | | | X | | | | X8) | | | UL | | | X1) | X1) | X | | | | | | X | X | CSA | X | X | | | | | | | | X4) | | | NEPSI | X11) | X11) | | | | X | | | | | | | INMETRO | X11) | X11) | | | | | | | | | | | Ordinary locations | UL listed (us, ca)Flowmeter | c-UL-us | | | | | | | X2) | X7) | | | | | UL recognized (us, ca) Flowmeter | c-UL-us | | | | | | | X2)5) | X5)6) | | | | | PED | | | Fluid group 1 Category II, Module H | PED Directive 2014/68/EU | X | X | | | | | | | | | | | CRN | | | Category F OF10769.5C | CRN | X11) | X11) | X | X10) | X | | | | | | X10) | X10) | F&B/Pharma | | | EHEDG | TUM | X11) | X11) | | | | | | | | | | | 3A | | X11) | X11) | | | | | | | | | | | Marine | | | Germanischer Lloyd/ det Norske Veritas, Bureau Veritas, Lloyds of London, American Bureau of Shipping | | X11) | | | | | | | | | | |
Note: Special conditions for safe use might be specified in certificates or operating instructions. X = available 1) Sensor pressure max. 100 bar (1450 psi) 2) Only remote version 3) Can be placed in zone 2 if mounted in minimum IP54 cabinet. 4) Only Ex version 5) 24 V; IP20 6) 115 … 230 V; IP20 7) 115 … 230 V; IP65 8) For sizes ≥ DN 100 only 9) Install in Div. 2, sensor interface into Div. 1, only Ex CT version 10) Only DI 6 is CRN 11) Does not apply for DN100 and DN150. Approvals pending.
|
|