SIWAREX R load cells, K series |
Possible applications | Container and hopper scales |
Model | Pressure force |
Rated load/maximum load Emax | 2.8/6/13/28/60/130/280 t |
Accuracy class | 0.2 % |
Combined error Fcomb | < 0.2 % Cn |
Temperature effect | |
| ≤ ± 0.025 % Cn/5 K |
| ≤ ± 0.025 % Cn/5 K |
Min. dead load Emin | ≤ 0 % Emax. |
Safe load limit Lu | 120 % Emax. |
Ultimate load Ld | 300 % Emax. |
Safe side load LIq | 10 % Emax. |
Rated measuring path hn at Emax. | 0.23 ... 2.67 mm |
Overload protection | – |
Supply voltage Usr (reference value) | 6 V |
Supply voltage (range) | 6 ... 12 V |
Rated characteristic value Cn | 1.5 mV/V |
Tolerance Dc of characteristic value | ± 0.5 % |
Tolerance Do of zero signal | ≤ ± 1.5 % Cn |
Input resistance Re | approx. 275 О© |
Output resistance Ra | 245 О© ± 0.2 О© |
Insulation resistance Ris | ≥ 20 MΩ |
Rated temperature range Btn | -10 ... + 60 °C |
Operating temperature range Btu | -20 ... + 70 °C |
Storage temperature range Bts | -30 ... + 80 °C |
Sensor material (DIN) | Steel, painted |
Degree of protection according to EN 60529; IEC 60529 | IP65 |
Cable connection | |
Function | Color |
| Red |
| White |
| Black |
| Blue |
| Transparent |