Electromagnetic flowmeters are suitable for measuring the flow of almost all electrically conductive liquids, pastes and slurries. A prerequisite is that the medium must have a minimum conductivity. The temperature, pressure, density and viscosity have no influence on the result. The main applications of the electromagnetic flowmeters can be found in the following sectors: - Water and waste water
- Chemical industries
- Pharmaceutical industries
- Food and beverage industry
- Mining, aggregates and cements industries
- Pulp and paper industry
- Steel industry
- Power; utility and chilled water industry
The wide variety of combinations and versions from the modular system means that ideal adaptation is possible to each measuring task. | | | | | | | | | | | | |
|---|
Please see Product selector on the Internet, because some constrains might be related to some of the features: http://www.pia-selector.automation.siemens.com  |  |  |  |  |  |  |  |  | MAG 1100 | MAG 1100 HT | MAG 1100 F | MAG 3100 | MAG 3100 HT | MAG 3100 P | MAG 5100 W | 911/E | MAG 8000/MAG 8000 CT | MAG 8000 Irrigation | 7ME6110 | 7ME6120 | 7ME6140 | 7ME6310 | 7ME6320 | 7ME6340 | 7ME6520 | 7ME6580 | 7ME5610 | 7ME6810 7ME6820 | 7ME6880 | Industry | Water/waste water | XX | | | XX | | X | XXX | XXX | X | XXX20) | XXX20) | Chemical | XXX | XXX | XX | XXX | XXX | XXX | X | X | | X | | Pharmaceutical | XX | XX | XXX | XX | XX | XX | X | X | | X | | Food and beverage | XX | | XXX | X | X | X | X | X | | X | | Mining, aggregates and cement | XX | | | XXX | | | X | X | XXX | X | | HPI | XX | X | | XX | X | XX | X | X | | X | | Other | XX | XX | XX | XX | XX | XX | XX | XX | XXX | X | | Design | Compact | x | | x | x | x | x | x | x | | x | x | Remote | x | x | x | x | x | x | x | x | x | x | x | Constant field (DC) | x | x | x | x | x | x | x | x | | x | x | Alternating field (AC) | | | | | | | | | x | | | Battery-operated constant field (DC) | | | | | | | | | | x | x | Size | DN 2 (1/12") | x | | | | | | | | | | | DN 3 (1/8") | x | | | | | | | | | | | DN 6 (¼") | x | | | | | | | | | | | DN 10 (3/8") | x | | x | | | | | | | | | DN 15 (½") | x | x | x | x | x | x | x | | x | | | DN 25 (1") | x | x | x | x | x | x | x | x | x | x | | DN 32 (1¼”) | | | x22) | | | | | | | | | DN 40 (1½") | x | x | x | x | x | x | x | x | x | x | | DN 50 (2”) | x | x | x | x | x | x | x | x | x | x | x | DN 65 (2½") | x | x | x | x | x | x | x | x | x | x | x | DN 80 (3") | x | x | x | x | x | x | x | x | x | x | x | DN 100 (4") | x | x | x | x | x | x | x | x | x | x | x | DN 125 (5") | | | | x | x | x | x | x | x | x | x | DN 150 (6") | | | | x | x | x | x | x | x | x | x | DN 200 (8") | | | | x | x | x | x | x | x | x | x | DN 250 (10") | | | | x | x | x | x | x | x | x | x | DN 300 (12") | | | | x | x | x | x | x | x | x | x | DN 350 (14") | | | | x | | | x | x | x | x | x | DN 400 (16") | | | | x | | | x | x | x | x | x | DN 450 (18") | | | | x | | | x | x | x | x | x | DN 500 (20") | | | | x | | | x | x | x | x | x | DN 600 (24") | | | | x | | | x | x | x | x | x | DN 700 (28") | | | | x | | | x | x | x | x | | DN 750 (30") | | | | x | | | x | x | x | x | | DN 800 (32") | | | | x | | | x | x | x | x | | DN 900 (36") | | | | x | | | x | x | x | x | | DN 1000 (40") | | | | x | | | x | x | x | x | | DN 1050 (42") | | | | x | | | x | x | | x | | DN 1100 (44") | | | | x | | | x | x | | x | | DN 1200 (48”) | | | | x | | | x | x | | x | | DN 1400 (56") | | | | x | | | | x | | | | DN 1500 (60") | | | | x | | | | x | | | | DN 1600 (66") | | | | x | | | | x | | | | DN 1800 (72") | | | | x | | | | x | | | | DN 2000 (78") | | | | x | | | | x | | | | Process connection | Wafer design | x | x | | | | | | | | | | Sanitary process connections | | | x | | | | | | | | | Flanges | | | | x | x | x | x | x | x | x | x 3) | Flange norms | EN 1092-1 | | | | x | x | x | x | x | x | x | x 3) | ANSI B 16.5 class 150 | | | | x | x | x | x | x | x | x | x 3) | ANSI B 16.5 class 300 | | | | x | x | | | | x | | | ASME B 16.47 class 150 | | | | x | | | | | | | | AWWA class D | | | | x | | | x | x | x | x | | AS 2129 | | | | x | x | | | | | | X 3) | AS 4087, PN 16 | | | | x | x | | x | x | | x | | AS 4087, PN 21 | | | | x | x | | | | | | | AS 4087, PN 35 | | | | x | x | | | | | | | JIS 10K | | | | x | | | | x | x | | | JIS 20K | | | | x | | | | | | | | Pressure rating 1) | PN 6 | | | | x | | | | x | | | | PN 10 | | | | x | x | x | x | x | x | x | | PN 16 | x | | x | x | x | x | x | x | x | x | | PN 25 | | | | x | x | | | | x | | | PN 40 | x | x | x | x | x | x | x | x | x | x | | PN 63 | | | | x | | | | | | | | PN 100 | | | | x | | | | | | | | Accuracy | Flow error ± 0.2 % of rate | x | x | x | x | x | x | x | x | | x | | Flow error ± 0.4 % of rate | x | x | x | x | x | x | x | x | | x | | Flow error ± 0.5 % of rate | | | | | | | | | x | | | Flow error ± 0.8 % of rate | | | | | | | | | | | x | Repeatability21) | 0.1 % | x | x | x | x | x | x | x | x | | x | x | 0.2 % | | | | | | | | | x | | | Grounding electrodes, incl. | | | | x 4) | | x 4) | x | x | (x) | x | | Grounding rings premounted from factory | | | | | | | | | | | x | Materials/temperature: | Liner material/max. temperatures | NBR Hard Rubber: 70 °C (158 °F) | | | | | | | x | | | | | EPDM: 70 °C (158 °F) | | | | x | | | x | | | x | | Soft rubber: 70 °C (158 °F) | | | | x | | | | | x | | | PTFE: 100 °C (212 °F) | | | | x | | | | | | | | PTFE: 130 °C (266 °F) | | | | | x | x | | | x | | | PTFE: 180 °C (356 °F) | | | | | x | | | | (x) 5) | | | Ebonite Hard Rubber: 95 °C (203 °F) | | | | x | | | | x 7) | x | | x 7) | Linatex: 70 °C (158 °F) | | | | x | | | | | x | | | Ceramic: 150 °C (302 °F) | x | | x | | | | | | | | | Ceramic: 200 °C (392 °F) | | x 6) | | | | | | | | | | PFA: 100 °C (212 °F) | | | | x | | | | | | | | PFA: 150 °C (302 °F) | x | | x | | x | x | | | | | | Novolak: 130 °C (266 °F) | | | | | | | | | x | | | Electrodes | Stainless steel | | | | x | x | | | | x | | x | Hastelloy C | x | | x | x | x | x | x | x | x | x | | Platinum | x | x | x | x | x | | | | x | | | Titanium | | | | x | x | | | | x | | | Tantalum | | | | x | x | | | | x | | | Flange/housing material | Carbon steel | | | | x | x | x | x | x | x | x | x | Stainless steel/carbon steel | | | | x | x | | | | x | | | Polished stainless steel | x | x | x | x | x | | | | | | | Approvals: | Custody transfer | Cold Water – MI-001 (EU) | | | | | | | x | | | x | | Cold water approval - OIML R 49/OIML R 49 MAA | | | | | | | | | | x 16) | | NMI 10(Australia) | | | | | | | | | | | x | Chilled water pattern approval - PTB K 7.2 | | | | | | | x 16) | | | x 16) | | OE 12/C 040 (Austria) Chilled water pattern approval | | | | | | | x | | | | | KIWA water approval | | | | | | | x | | | x | | Marine | | | | | | | | | | | | ABS | | | | | | | x | | | | | Bureau Veritas | | | | | | | x | | | | | DNV | | | | | | | x | | | | | GL | | | | | | | x | | | | | Lloyd's Register | | | | | | | x | | | | | Hazardous areas | ATEX – 2 GD (Zone 1/21) | x | x | x | x | x | x | | | | | | IECEx Zone 1/21 | | | | x | x | x | | | | | | FM Class I/II/III, Div 1 | | | | x19) | x 19) | x 19) | | | | | | FM Class I, Zone 1/21 | | | | x | x | x | | | | | | FM - Class I, Div 2 | x | x | x | x | x | x | x | x | | | | FM - Class I, Zone 2 | x | x | x | x | x | x | x | x | | | | CSA Class I, Zone 1/21 | | | | x | x | x | | | | | | CSA - Class I, Div 2 | | | | x | x | x | x | x | | | | NEPSI Zone 1 | | | | x | | x | | | | | | EAC Ex | x | x | x | x | x | x | | | | | | Hygienic | EHEDG | | | x | | | | | | | | | 3A | | | x | | | | | | | | | EC 1935:2004 European food contact material | | | x | | | | | | | | | Drinking water | WRAS (WRc) | | | | x | | | x 12) | x | | x | x | ANSI/NSF 61 (US) 18) | | | | x 13) | | | x | x | | x | x | ACS (FR) EPDM liner | | | | x | | | x | | | x | | Belgaqua (B) EPDM liner | | | | x | | | x | | | x | | DVGW-W270 (D) EPDM liner | | | | x | | | x | | | x | | KIWA (NL) EPDM liner | | | | | | | x | | | | | MCERTS (GB environmental) | | | | x 14) | | | x 12) | | | x | | Other | CRN (Canada) | x 23) | | | x | x | x | x | x | | x | | FM Fire Service (class number 1044) | | | | | | | x 17) | | | x 17) | | EAC (Russia, Belarus, and Kasakhstan) | x | x | x | x | x | x | x | x | x | x | | CMC/CPA (China) | | | | x | | | | x | | | x | PED 2014/68/EU | x | x | x | x | x | x | x | x | x | | x | VdS | | | | | | | x 15) | | | | | Verificator compatible | x 10) | x 10) | x 10) | x 10) | x 10) | x 10) | x 10) | x 10) | | | |
x = available X = can be used XX = often used XXX = most often used 1) Pressure may be limited by the liner material chosen. 3) On request 4) Drilled pattern flange max. 7 bar (107 psi) 5) Optional on PFA 6) 150 °C (302 °F) 7) Ex sensor: 180 °C (356 °F) 8) 70 °C (158 °F) 10) Only in combination with MAG 5000 and MAG 6000 transmitters 11) Only with sensor sizes DN 15 to DN 300 (½" to 12") compact 12) EPDM liner 13) Only EPDM with Hastelloy electrodes 14) EPDM or PTFE liner with AISI 316 or Hastelloy electrodes 15) Only valid for DN 50 to DN 300 (2" to 12") 16) For verification submit Product Variation Request (PVR) 17) Sizes: DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class 150 flanges 18) Including Annex G 19) Only DN 15 to DN 300 (½" to 12") with MAG 6000 I Ex, compact mounted 20) Not suitable for wastewater applications 21) Of actual flow for v ≥ 0.5 m/s (15 ft/s) and conductivity > 10 μS/cm 22) Only in combination with DN 32 adapter A5E02054637, A5E02218297, FDK:083G2120 and FDK:083G2160 23) Only PFA liner | | | | | | | | | |
|---|
Please see Product selector on the Internet, because some constrains might be related to some of the features: http://www.pia-selector.automation.siemens.com  |  |  |  |  |  |  |  | MAG 5000 | MAG 6000 | MAG 6000 I | MAG 6000 I Ex | MAG 6000 + Safety barrier | TRANSMAG 2 | MAG 8000/ MAG 8000 CT | MAG 8000 Irrigation | 7ME6910 | 7ME6920 | 7ME6930 | 7ME6930 | 7ME6920 | 7ME5034 | 7ME6810 7ME6820 | 7ME6880 | Industry | Water/waste water | XXX | XXX | XX | X | | X | XXX | XXX | Chemical | X | XX | XX | XXX | X | | X | | Pharmaceutical | X | XXX | XX | XXX | X | | X | | Food and beverage | XX | XXX | XX | | | | X | | Mining, aggregates and cement | XX | X | XX | X | | XXX | X | | HPI | X | X | X | XX | | | X | | Other | XX | XX | XX | XX | | XX | X | | Design | Compact | x | x | x | x | | | x | x | Remote | x | x | x | x | x | x | x | x | Constant field (DC) | x | x | x | x | x | | x | x | Alternating field (AC) | | | | | | x | | | Battery-operated constant field (DC) | | | | | | | x | x | Enclosure transmitter | Polyamide, IP67 | x | x | | | | | | | Die-cast aluminum | | | x | x | | x | | | Stainless steel | | x | | | | | x 1) | x 1) | 19” rack | x | x | | | x | | | | Front panel mounting | x | x | | | x | | | | Panel mounting | x | x | | | x | | | | IP66 wall mounting | x | x | x | x | x | | | | Accuracy | Flow error ± 0.2 % of rate | | x | x | x | x | | x | | Flow error ± 0.4 % of rate | x | | | | | | x | | Flow error ± 0.5 % of rate | | | | | | x | | | Flow error ± 0.8 % of rate | | | | | | | | x | Repeatability7) | 0.1 % | x | x | x | x | x | | x | x | 0.2 % | | | | | | x | | | Communication | HART | x | x | x | x | x | x | | | PROFIBUS PA | | x | x | x | x | x | | | PROFIBUS DP | | x | x | | x | | | | FOUNDATION Fieldbus H1 | | x | x | x | x | | | | DeviceNet | | x | x | | x | | | | Modbus RTU/RS 485 | | x | x | | x | | x 2) | x 2) | Encoder interface module (Sensus protocol for Itron 200WP radio | | | | | | | x | x | GSM/GPRS module | | | | | | | x | | Batching | | x | x | x | x | | | | Power supply | 24 V | x 3) | x 3) | x | x | | | x 3) 4) | x 3) 4) | 115 V - 230 V | x | x | x | x | x | x | x 4) | x 4) | Battery | | | | | | | x | | Approvals | Custody transfer | Cold water - MI-001 (EU) | x | x | | | | | x | | Cold water approval - OIML R 49/OIML R 49 MAA | | | | | | | x | | Chilled water pattern approval PTB K 7.2 | x 8) | x 8) | | | | | x 8) | | OE12/C 040 (Austria) Chilled water pattern approval | x | x | | | | | | | KIWA water approval | | x | | | | | x | | Marine | | | | | | | | | ABS | x | x | | | | | | | Bureau Veritas | x | x | | | | | | | DNV | x | x | | | | | | | GL | x | x | | | | | | | Lloyd's Register | x | x | | | | | | | Hazardous areas | ATEX - 2G GD (Zone 1/21) | | | | x | (x) 5) | | | | IECEx Gb Zone 1/21 | | | | x | | | | | FM Class I/II/III, Div 1 | | | | x 6) | | | | | FM Class I, Zone 1/21 | | | | x | | | | | FM Class I, Div 2 | x | x | x | | | | | | FM Class I, Zone 2 | x | x | x | | | | | | CSA Class I, Zone 1/21 | | | | x | | | | | CSA Class I, Div 2 | x | x | x | | | | | | UL/C-UL-general safety | x | x | | | x | | | | NEPSI Zone 1 | | | | x | | | | | EAC Ex | | | | x | x | | | | Other | FM Fire Service (1044) | x | x | | | | | x | | C - tick (Australia) | x | x | x | x | x | | | | EAC (Russia, Belarus, Kazakhstan) | x | x | x | x | x | x | x | | CMC/CPA (China) | x | x | x | x | | | | x | VdS | x | x | | | | | | | Other national approvals, see internet | x | x | x | x | x | x | x | x | Verificator compatible | x | x | | | | | | |
x = available X = can be used XX = often used XXX = most often used 1) IP68 enclosure 2) Modbus RTU also as serial RS 232 3) 12/24 V AC/DC 4) Main power with battery backup 5) Only sensor in hazardous area 6) Only with sensors sizes DN 15 to DN 300 (½" to 12") compact 7) Of actual flow for v ≥ 0.5 m/s (1.5 ft/s) and conductivity > 10 μS/cm 8) For verification submit Product Variation Request (PVR) For more national approvals please check our internet page http://support.automation.siemens.com/WW/view/en/10806954/134200 SITRANS F M compact installation |
|---|
 | + |  | = |  | MAG 6000 transmitter | MAG 3100 sensor | MAG 6000 compact mounted on a MAG 3100 sensor | Example | Sensor | | 7ME6310-3TC11-1JA1 | Pipe size | DN 100 | Liner | Soft rubber | Electrodes | SS 316 | Flanges | EN 1092-1, PN 16 | Transmitter | MAG 6000, Polyamide, 115 … 230 V AC | Accuracy | ± 0.2 % ± 1 mm/s | Supply | 230 V AC |
Note: MAG 5000/6000 transmitters, sensors and communication modules are packed in separate boxes, the final assembly takes place during installation at the customer's place. SITRANS F M remote installation |
|---|
 | + |  | = |  | Wall bracket | MAG 6000 | |  | + |  | = |  | MAG 3100 | 2 x cable | MAG 3100 remote installation | Example | | Sensor | | 7ME6310-3TC11-1AA1 | Pipe size | DN 100 | Liner | Soft rubber | Electrodes | SS 316 | Flanges | EN 1092-1, PN 16 | Transmitter | 7ME6920-1AA10-0AA0 | Accuracy | ± 0.2 % ± 1 mm/s | Supply | 230 V AC | Wall mounting kit | FDK:085U1018 | Cable kit with sensor cable and electrode cable | A5E01181647 |
|
|