System information SITRANS F M Electromagnetic flowmeters are suitable for measuring the flow of almost all electrically conductive liquids, pastes and slurries.
A prerequisite is that the medium must have a minimum conductivity. The temperature, pressure, density and viscosity have no influence on the result.
The main applications of the electromagnetic flowmeters can be found in the following sectors:
Water and waste water Chemical industries Pharmaceutical industries Food and beverage industry Mining, aggregates and cements industries Pulp and paper industry Steel industry Power; utility and chilled water industry The wide variety of combinations and versions from the modular system means that ideal adaptation is possible to each measuring task.
Please see Product selector on the Internet, because some constrains might be related to some of the features:http://www.pia-selector.automation.siemens.com
MAG 1100
MAG 1100 HT
MAG 1100 F
MAG 3100
MAG 3100 HT
MAG 3100 P
MAG 5100 W
911/E
MAG 8000/MAG 8000 CT
MAG 8000 Irrigation
7ME6110
7ME6120
7ME6140
7ME6310
7ME6320
7ME6340
7ME6520
7ME6580
7ME5610
7ME6810 7ME6820
7ME6880
Industry
Water/waste water
XX
XX
X
XXX
XXX
X
XXX20)
XXX20)
Chemical
XXX
XXX
XX
XXX
XXX
XXX
X
X
X
Pharmaceutical
XX
XX
XXX
XX
XX
XX
X
X
X
Food and beverage
XX
XXX
X
X
X
X
X
X
Mining, aggregates and cement
XX
XXX
X
X
XXX
X
HPI
XX
X
XX
X
XX
X
X
X
Other
XX
XX
XX
XX
XX
XX
XX
XX
XXX
X
Design
Compact
x
x
x
x
x
x
x
x
x
Remote
x
x
x
x
x
x
x
x
x
x
x
Constant field (DC)
x
x
x
x
x
x
x
x
x
x
Alternating field (AC)
x
Battery-operated constant field (DC)
x
x
Size
DN 2 (1 /12 ")
x
DN 3 (1 /8 ")
x
DN 6 (?")
x
DN 10 (3 /8 ")
x
x
DN 15 (?")
x
x
x
x
x
x
x
x
DN 25 (1")
x
x
x
x
x
x
x
x
x
x
DN 32 (1?”)
x22)
DN 40 (1?")
x
x
x
x
x
x
x
x
x
x
DN 50 (2”)
x
x
x
x
x
x
x
x
x
x
x
DN 65 (2?")
x
x
x
x
x
x
x
x
x
x
x
DN 80 (3")
x
x
x
x
x
x
x
x
x
x
x
DN 100 (4")
x
x
x
x
x
x
x
x
x
x
x
DN 125 (5")
x
x
x
x
x
x
x
x
DN 150 (6")
x
x
x
x
x
x
x
x
DN 200 (8")
x
x
x
x
x
x
x
x
DN 250 (10")
x
x
x
x
x
x
x
x
DN 300 (12")
x
x
x
x
x
x
x
x
DN 350 (14")
x
x
x
x
x
x
DN 400 (16")
x
x
x
x
x
x
DN 450 (18")
x
x
x
x
x
x
DN 500 (20")
x
x
x
x
x
x
DN 600 (24")
x
x
x
x
x
x
DN 700 (28")
x
x
x
x
x
DN 750 (30")
x
x
x
x
x
DN 800 (32")
x
x
x
x
x
DN 900 (36")
x
x
x
x
x
DN 1000 (40")
x
x
x
x
x
DN 1050 (42")
x
x
x
x
DN 1100 (44")
x
x
x
x
DN 1200 (48”)
x
x
x
x
DN 1400 (56")
x
x
DN 1500 (60")
x
x
DN 1600 (66")
x
x
DN 1800 (72")
x
x
DN 2000 (78")
x
x
Process connection
Wafer design
x
x
Sanitary process connections
x
Flanges
x
x
x
x
x
x
x
x 3)
Flange norms
EN 1092-1
x
x
x
x
x
x
x
x 3)
ANSI B 16.5 class 150
x
x
x
x
x
x
x
x 3)
ANSI B 16.5 class 300
x
x
x
ASME B 16.47 class 150
x
AWWA class D
x
x
x
x
x
AS 2129
x
x
X 3)
AS 4087, PN 16
x
x
x
x
x
AS 4087, PN 21
x
x
AS 4087, PN 35
x
x
JIS 10K
x
x
x
JIS 20K
x
Pressure rating 1)
PN 6
x
x
PN 10
x
x
x
x
x
x
x
PN 16
x
x
x
x
x
x
x
x
x
PN 25
x
x
x
PN 40
x
x
x
x
x
x
x
x
x
x
PN 63
x
PN 100
x
Accuracy
Flow error ± 0.2 % of rate
x
x
x
x
x
x
x
x
x
Flow error ± 0.4 % of rate
x
x
x
x
x
x
x
x
x
Flow error ± 0.5 % of rate
x
Flow error ± 0.8 % of rate
x
Repeatability21)
0.1 %
x
x
x
x
x
x
x
x
x
x
0.2 %
x
Grounding electrodes, incl.
x 4)
x 4)
x
x
(x)
x
Grounding rings premounted from factory
x
Materials/temperature:
Liner material/max. temperatures
NBR Hard Rubber: 70 °C (158 °F)
x
EPDM: 70 °C (158 °F)
x
x
x
Soft rubber: 70 °C (158 °F)
x
x
PTFE: 100 °C (212 °F)
x
PTFE: 130 °C (266 °F)
x
x
x
PTFE: 180 °C (356 °F)
x
(x) 5)
Ebonite Hard Rubber: 95 °C (203 °F)
x
x 7)
x
x 7)
Linatex: 70 °C (158 °F)
x
x
Ceramic: 150 °C (302 °F)
x
x
Ceramic: 200 °C (392 °F)
x 6)
PFA: 100 °C (212 °F)
x
PFA: 150 °C (302 °F)
x
x
x
x
Novolak: 130 °C (266 °F)
x
Electrodes
Stainless steel
x
x
x
x
Hastelloy C
x
x
x
x
x
x
x
x
x
Platinum
x
x
x
x
x
x
Titanium
x
x
x
Tantalum
x
x
x
Flange/housing material
Carbon steel
x
x
x
x
x
x
x
x
Stainless steel/carbon steel
x
x
x
Polished stainless steel
x
x
x
x
x
Approvals:
Custody transfer
Cold Water – MI-001 (EU)
x
x
Cold water approval - OIML R 49/OIML R 49 MAA
x 16)
NMI 10(Australia)
x
Chilled water pattern approval - PTB K 7.2
x 16)
x 16)
OE 12/C 040 (Austria) Chilled water pattern approval
x
KIWA water approval
x
x
Marine
ABS
x
Bureau Veritas
x
DNV
x
GL
x
Lloyd's Register
x
Hazardous areas
ATEX – 2 GD (Zone 1/21)
x
x
x
x
x
x
IECEx Zone 1/21
x
x
x
FM Class I/II/III, Div 1
x19)
x 19)
x 19)
FM Class I, Zone 1/21
x
x
x
FM - Class I, Div 2
x
x
x
x
x
x
x
x
FM - Class I, Zone 2
x
x
x
x
x
x
x
x
CSA Class I, Zone 1/21
x
x
x
CSA - Class I, Div 2
x
x
x
x
x
NEPSI Zone 1
x
x
EAC Ex
x
x
x
x
x
x
Hygienic
EHEDG
x
3A
x
EC 1935:2004 European food contact material
x
Drinking water
WRAS (WRc )
x
x 12)
x
x
x
ANSI/NSF 61 (US) 18)
x 13)
x
x
x
x
ACS (FR) EPDM liner
x
x
x
Belgaqua (B) EPDM liner
x
x
x
DVGW-W270 (D) EPDM liner
x
x
x
KIWA (NL) EPDM liner
x
MCERTS (GB environmental)
x 14)
x 12)
x
Other
CRN (Canada)
x 23)
x
x
x
x
x
x
x
FM Fire Service (class number 1044)
x 17)
x 17)
EAC (Russia, Belarus, and Kasakhstan)
x
x
x
x
x
x
x
x
x
x
CMC/CPA (China)
x
x
x
PED 2014/68/EU
x
x
x
x
x
x
x
x
x
x
VdS
x 15)
Verificator compatible
x 10)
x 10)
x 10)
x 10)
x 10)
x 10)
x 10)
x 10)
x = available
X = can be used
XX = often used
XXX = most often used
1) Pressure may be limited by the liner material chosen.
3) On request
4) Drilled pattern flange max. 7 bar (107 psi)
5) Optional on PFA
6) 150 °C (302 °F)
7) Ex sensor: 180 °C (356 °F)
8) 70 °C (158 °F)
10) Only in combination with MAG 5000 and MAG 6000 transmitters
11) Only with sensor sizes DN 15 to DN 300 (?" to 12") compact
12) EPDM liner
13) Only EPDM with Hastelloy electrodes
14) EPDM or PTFE liner with AISI 316 or Hastelloy electrodes
15) Only valid for DN 50 to DN 300 (2" to 12")
16) For verification submit Product Variation Request (PVR)
17) Sizes: DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class 150 flanges
18) Including Annex G
19) Only DN 15 to DN 300 (?" to 12") with MAG 6000 I Ex, compact mounted
20) Not suitable for wastewater applications
21) Of actual flow for v ? 0.5 m/s (15 ft/s) and conductivity > 10 ?S/cm
22) Only in combination with DN 32 adapter A5E02054637, A5E02218297, FDK:083G2120 and FDK:083G2160
23) Only PFA liner
Please see Product selector on the Internet, because some constrains might be related to some of the features:http://www.pia-selector.automation.siemens.com
MAG 5000
MAG 6000
MAG 6000 I
MAG 6000 I Ex
MAG 6000 + Safety barrier
TRANSMAG 2
MAG 8000/ MAG 8000 CT
MAG 8000 Irrigation
7ME6910
7ME6920
7ME6930
7ME6930
7ME6920
7ME5034
7ME6810 7ME6820
7ME6880
Industry
Water/waste water
XXX
XXX
XX
X
X
XXX
XXX
Chemical
X
XX
XX
XXX
X
X
Pharmaceutical
X
XXX
XX
XXX
X
X
Food and beverage
XX
XXX
XX
X
Mining, aggregates and cement
XX
X
XX
X
XXX
X
HPI
X
X
X
XX
X
Other
XX
XX
XX
XX
XX
X
Design
Compact
x
x
x
x
x
x
Remote
x
x
x
x
x
x
x
x
Constant field (DC)
x
x
x
x
x
x
x
Alternating field (AC)
x
Battery-operated constant field (DC)
x
x
Enclosure transmitter
Polyamide, IP67
x
x
Die-cast aluminum
x
x
x
Stainless steel
x
x 1)
x 1)
19” rack
x
x
x
Front panel mounting
x
x
x
Panel mounting
x
x
x
IP66 wall mounting
x
x
x
x
x
Accuracy
Flow error ± 0.2 % of rate
x
x
x
x
x
Flow error ± 0.4 % of rate
x
x
Flow error ± 0.5 % of rate
x
Flow error ± 0.8 % of rate
x
Repeatability7)
0.1 %
x
x
x
x
x
x
x
0.2 %
x
Communication
HART
x
x
x
x
x
x
PROFIBUS PA
x
x
x
x
x
PROFIBUS DP
x
x
x
FOUNDATION Fieldbus H1
x
x
x
x
DeviceNet
x
x
x
Modbus RTU/RS 485
x
x
x
x 2)
x 2)
Encoder interface module (Sensus protocol for Itron 200WP radio
x
x
GSM/GPRS module
x
Batching
x
x
x
x
Power supply
24 V
x 3)
x 3)
x
x
x 3) 4)
x 3) 4)
115 V - 230 V
x
x
x
x
x
x
x 4)
x 4)
Battery
x
Approvals
Custody transfer
Cold water - MI-001 (EU)
x
x
x
Cold water approval - OIML R 49/OIML R 49 MAA
x
Chilled water pattern approval PTB K 7.2
x 8)
x 8)
x 8)
OE12/C 040 (Austria) Chilled water pattern approval
x
x
KIWA water approval
x
x
Marine
ABS
x
Bureau Veritas
x
DNV
x
GL
x
Lloyd's Register
x
Hazardous areas
ATEX - 2G GD (Zone 1/21)
x
(x) 5)
IECEx Gb Zone 1/21
x
FM Class I/II/III, Div 1
x 6)
FM Class I, Zone 1/21
x
FM Class I, Div 2
x
x
x
FM Class I, Zone 2
x
x
x
CSA Class I, Zone 1/21
x
CSA Class I, Div 2
x
x
x
UL/C-UL-general safety
x
x
x
NEPSI Zone 1
x
EAC Ex
x
x
Other
FM Fire Service (1044)
x
x
x
C - tick (Australia)
x
x
x
x
x
EAC (Russia, Belarus, Kazakhstan)
x
x
x
x
x
x
x
CMC/CPA (China)
x
x
x
x
x
VdS
x
x
Other national approvals, see internet
x
x
x
x
x
x
x
x
Verificator compatible
x
x
x = available
X = can be used
XX = often used
XXX = most often used
1) IP68 enclosure
2) Modbus RTU also as serial RS 232
3) 12/24 V AC/DC
4) Main power with battery backup
5) Only sensor in hazardous area
6) Only with sensors sizes DN 15 to DN 300 (?" to 12") compact
7) Of actual flow for v ? 0.5 m/s (1.5 ft/s) and conductivity > 10 ?S/cm
8) For verification submit Product Variation Request (PVR)
For more national approvals please check our internet pagehttp://support.automation.siemens.com/WW/view/en/10806954/134200
SITRANS F M compact installation
+
=
MAG 6000 transmitter
MAG 3100 sensor
MAG 6000 compact mounted on a MAG 3100 sensor
Example
Sensor
7ME6310-3TC11-1JA1
Pipe size
DN 100
Liner
Soft rubber
Electrodes
SS 316
Flanges
EN 1092-1, PN 16
Transmitter
MAG 6000, Polyamide, 115 … 230 V AC
Accuracy
± 0.2 % ± 1 mm/s
Supply
230 V AC
Note: MAG 5000/6000 transmitters, sensors and communication modules are packed in separate boxes, the final assembly takes place during installation at the customer's place.
SITRANS F M remote installation
+
=
Wall bracket
MAG 6000
+
=
MAG 3100
2 x cable
MAG 3100 remote installation
Example
Sensor
7ME6310-3TC11-1AA1
Pipe size
DN 100
Liner
Soft rubber
Electrodes
SS 316
Flanges
EN 1092-1, PN 16
Transmitter
7ME6920-1AA10-0AA0
Accuracy
± 0.2 % ± 1 mm/s
Supply
230 V AC
Wall mounting kit
FDK:085U1018
Cable kit with sensor cable and electrode cable
A5E01181647