General information | В |
Measuring ranges | 4, internally and externally switchable; manual and autoranging possible |
Smallest possible measuring span | 0В ... 10 vpm |
Largest possible measuring span | 99.999 vpm*) |
Concentration units | vpm, C1, C3, C6 or mgC/m3 |
Autoranging | Hysteresis, selectable |
Measured-value display | Digital concentration display (5В digits with floating point) |
Resolution of digital display | 0.1% of measured value |
Operating position | Front wall, vertical |
Conformity | CE mark EN 50081‑1, EN 50082‑2 |
Oven temperature | Adjustable, 100В ... 200 В°C |
Design, enclosure | В |
Degree of protection | IP20 according to ENВ 60529 |
Weight | Approx. 23 kg |
Electrical characteristics | В |
Auxiliary power | 100 ... 120 V AC (nominal range of use 90 ... 132 V), 48 ... 63 Hz or 200 ... 240 V AC (nominal range of use 180 ... 264 V), 48 ... 63 Hz |
Power consumption | - Approx. 150 VA during operation,
- Approx. 350В VA during warm-up phase
|
EMC interference immunity (electromagnetic compatibility) | In accordance with standard requirements of NAMUR NE21 (08/98) |
Electrical safety | In accordance with ENВ 61010-1, overvoltage category II |
Fuse values | - 100В ... 120В V: 4.0T/250
- 200В ...В 240 V: 2.5 T/250
|
Gas inlet conditions | В |
Permissible sample gas pressure | В |
| <В 2В 000В hPa abs. |
| 600В ... 1В 100В hPa |
Sample gas temperature | 0В ... 200 В°C |
Sample gas humidity | <В 90% RH (RH: relative humidity) |
Dynamic response | В |
Warm-up period | At room temperature, approx.В 2В ...В 3В h |
Delayed display (T90) | 2В ... 3В s |
Damping (electrical time constant) | 0В ... 100В s, configurable |
Dead time (purging time of the gas path in the unit at 1 l/min) | With filter, 2В ... 3В s |
Time for device-internal signal processing | <В 1В s |
Measuring response | Based on sample gas pressure 1В 013В hPa absolute, 0.5 l/min sample gas flow and 25В В°C ambient temperature |
Output signal fluctuation | <В 0.75% of the smallest possible measuring range according to rating plate, with electronic damping constant of 1В s (corresponds to В±В 0.25% at 2В Пѓ) |
Zero point drift | <В 0.5%/month of the smallest possible measuring span according to rating plate |
Measured-value drift | <В 1%/week of the current measuring range |
Repeatability | <В 1% of the current measuring range |
Detection limit | 0.1В vpm (version for ultra-pure gas measurement: 50В ppb) |
Linearity error | <В 1% of the current measuring range |
Influencing variables | Based on sample gas pressure 1В 013В hPa absolute, 0.5В l/min sample gas flow and 25В В°C ambient temperature |
Ambient temperature | <В 1%/10 K referred to smallest possible span according to rating plate |
Atmospheric pressure | < 1%/50В hPa |
Sample gas pressure | <В 2% of the current measuring range/1% pressure change (within 600В ... 1В 100В hPa) |
Auxiliary power | < 1% of the current measuring range with rated voltage В± 10% |
Position influence | <В 1% with <В 15В° inclination |
Electrical inputs and outputs | В |
Analog output | 0/2/4В ... 20В mA, isolated; max. load 750В О© |
Relay outputs | 6, with changeover contacts, freely configurable, e.g. for measuring range identification; load: 24В V AC/DC/1В A, potential-free |
Analog inputs | 2, dimensioned for 0/2/4 to 20В mA for external pressure sensor and correction of influence of accompanying gas (correction of cross-interference) |
Digital inputs | 6, designed for 24 V, floating, freely configurable, e.g. for measuring range switchover |
Serial interface | RSВ 485 |
Options | AUTOCAL function each with 8 additional digital inputs and relay outputs; also with PROFIBUSВ PA or PROFIBUSВ DP |
Climatic conditions | В |
Permissible ambient temperature | 5В ... 45В В°C in operation, -30В ... +70В В°C during storage and transportation |
Permissible humidity | <В 90% RH (RH: relative humidity) as annual average, during storage and transportation (must not fall below dew point) |