Siemens
ÑÐÅÄÑÒÂÀ ÏÐÎÌÛØËÅÍÍÎÉ ÀÂÒÎÌÀÒÈÇÀÖÈÈ
îôèöèàëüíûé ïàðòíåð Ñèìåíñ
(4872) 700-366
skenergo@mail.ru
Special versions
Voltages

Additional order codes for other voltages or voltage codes (without -Z supplement)

For some non-standard voltages at 50 or 60 Hz, order codes are specified. They are ordered by specifying the code digit9 for voltage in the 11th position of the Order No. and the appropriate order code.

Special versions

Voltage code 11th position of Order No.

Additional identifica­tion code with order code and plain text if necessary

Motor type frame size








315

355

400

450

Self-ventilated motors for mains-fed operation - Cast-iron series 1LA8
Self-ventilated motors for converter-fed operation - Cast-iron series 1LA8

1LA8

Voltage at 60 Hz

380 V?/660 VY; 50-Hz output 1)

9

L2C

? 

? 

? 

? 

380 V?/660 VY; 60-Hz output 1)

9

L2D

? 

? 

? 

? 

440 V?; 50-Hz output 1)

9

L2R

? 

? 

? 

? 

440 V?; 60-Hz output 1)

9

L2X

? 

? 

? 

? 

460 V?; 50-Hz output 1)

9

L2T

? 

? 

? 

? 

460 V?; 60-Hz output 1)

9

L2F

O 

O 

O 

O 

575 V?; 50-Hz output

9

L2V

? 

? 

? 

? 

575 V?; 60-Hz output

9

L2M

O 

O 

O 

O 

Non-standard voltage and/or frequencies

Standard winding (winding according to voltage code 0, 4, 5, 6, 7 or 8; rating plate will be stamped in accor­dance with order)2)

9

L8Y •

O 

O 

O 

O 

Non-standard winding for volt­ages between 380 and 690 V (voltages outside this range
are available on request)2)

9

L1Y •

? 

? 

? 

? 


O Without additional charge

? With additional charge

• This order code only determines the price of the version - Additional plain text is required

1) Only possible with rated outputs of up to 630 kW.

2) Plain text must be specified in the order: Voltage, frequency, circuit, required rated output in kW.

Special versions

Voltage code 11th position of Order No.

Additional identifica­tion code with order code and plain text if necessary

Motor type frame size








315

355

400

450

Forced-air cooled motors with externally-mounted fan for converter-fed operation - Cast-iron series 1PQ8

1PQ8

Voltage at 60 Hz

380 V?/660 VY; 50-Hz-output 1)

9

L2C

? 

? 

? 

? 

380 V?/660 VY; 60-Hz-output 1)

9

L2D

? 

? 

? 

? 

440 V?; 50-Hz-output 1)

9

L2R

? 

? 

? 

? 

440 V?; 60-Hz-output 1)

9

L2X

? 

? 

? 

? 

460 V?; 50-Hz-output 1)

9

L2T

? 

? 

? 

? 

460 V?; 60-Hz-output 1)

9

L2F

O 

O 

O 

O 

575V?; 50-Hz-output

9

L2V

? 

? 

? 

? 

575V?; 60-Hz-0utput

9

L2M

O 

O 

O 

O 

Non-standard voltage and/or frequencies

Standard winding (winding according to voltage code 4, 5, 7 or 8; rating plate will be stamped in accordance with order)2)

9

L8Y •

O 

O 

O 

O 

Non-standard winding for volt­ages between 380 and 690 V (voltages outside this range
are available on request)2)

9

L1Y •

? 

? 

? 

? 


O Without additional charge

? With additional charge

• This order code only determines the price of the version - Additional plain text is required

1) Only possible with rated outputs of up to 630 kW.

2) Plain text must be specified in the order: Voltage, frequency, circuit, required rated output in kW.

Special versions

Voltage code 11th position of Order No.

Additional identifica­tion code with order code and plain text if necessary

Motor type frame size








315

355

400

450

Self-ventilated motors with through ventilation for mains-fed and converter-fed operation - Cast-iron series 1LL8

1LL8

Voltage at 60 Hz

380 V?/660 VY; 50-Hz-Output 1)

9

L2C

? 

? 3)

? 3)

? 3)

380 V?/660 VY; 60-Hz-Output 1)

9

L2D

? 

? 

? 

? 

440 V?; 50-Hz-Output 1)

9

L2R

? 

? 

? 

? 

440 V?; 60-Hz-Output 1)

9

L2X

? 

? 

? 

? 

460 V?; 50-Hz-Output 1)

9

L2T

? 

? 

? 

? 

460 V?; 60-Hz-Output 1)

9

L2F

O 

O 

O 

O 

575 V?; 50-Hz-Output

9

L2V

? 

? 

? 

? 

575 V?; 60-Hz-Output

9

L2M

O 

O 

O 

O 

Non-standard voltage and/or frequencies

Standard winding (winding according to voltage code 0, 5 or 6; rating plate will be stamped in accordance
with order)2)

9

L8Y •

O 

O 

O 

O 

Non-standard winding for volt­ages between 380 and 690 V (voltages outside this range
are available on request)2)

9

L1Y •

? 

? 

? 

? 


O Without additional charge

? With additional charge

• This order code only determines the price of the version - Additional plain text is required

1) Only possible with rated outputs of up to 630 kW.

2) Plain text must be specified in the order: Voltage, frequency, circuit, required rated output in kW.

3) Not possible for 2-pole motors in 60 Hz version of frame size 355 and above.

Options

Options or order codes (supplement -Z is required)

Special versions

Additional identifica­tion code with order code and plain text if necessary

Motor type frame size








315

355

400

450

315

355

400

450

Self-ventilated motors for mains-fed and converter-fed operation 1LA8

1LA8Mains-fed operation

1LA8Converter-fed operation

Standardline

Standardline version1)

B20

v 

v 

– 

– 

v 

v 

– 

– 

Motor protection

Motor protection with PTC thermistors with 6 embedded temperature sensors for alarm and tripping2)

A12

? 

? 

? 

? 

? 

? 

? 

? 

Motor temperature detection with embedded temperature sensor KTY84-1303)

A23

O 

O 

O 

O 

O 

O 

O 

O 

Installation of 6 PT 100 resistance thermometers in stator winding3)

A61

? 

? 

? 

? 

? 

? 

? 

? 

Installation of 2 PT 100 screw-in
resistance thermometers (basic circuit) for rolling-contact bearings

A72

? 

? 

? 

? 

? 

? 

? 

? 

Motor connection and connection boxes

Two-part plate on connection box

K06

? 4)

? 

? 

? 

O. R.

O. R.

O. R.

O. R.

Undrilled entry plate

L01

O 4)

O 

O 

O 

O 4)

O 

O 

O 

Connection box on RHS

K09

? 

? 

? 

? 

? 

? 

? 

? 

Connection box on LHS

K10

O 

O 

O 

O 

O 

O 

O 

O 

Connection box above
(1XB1 634 connection box)5)

K11

? 

? 

? 

? 

? 

? 

? 

? 

Cable entry DIN 89280,
maximum configuration

K57

? 

? 

? 

? 

? 

? 

? 

? 

Rotation of the connection box through 90°, entry from DE

K83

O 

O 

O 

O 

O 

O 

O 

O 

Rotation of the connection box through 90°, entry from NDE

K84

O 

O 

O 

O 

O 

O 

O 

O 

Rotation of the connection box
through 180°

K85

O 

O 

O 

O 

O 

O 

O 

O 

Larger connection box
(1XB1 621 connection box)

M58

? 

? 6)

– 

– 

? 

? 

– 

– 

Larger connection box
(1XB1 631 connection box)

L00

? 

? 7)

? 

? 

? 

? 7)

? 

? 

6 cables protruding, 1.5 m long

L48

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

6 cables protruding, 3 m long

L49

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

Auxiliary connection box 1XB9 016 (cast-iron)

M50

? 

? 

? 

? 

? 

? 

? 

? 

Auxiliary connection box
1XB3 0208)

L97

? 

? 

? 

? 

? 

? 

? 

? 

Auxiliary connection box 1XB9 014 (aluminum)

M88

? 

? 

? 

? 

? 

? 

? 

? 

Connection box on NDE

M64

? 

? 

? 

? 

? 

? 

? 

? 

Windings and insulation

Temperature class 155 (F), used acc.
to 155 (F), with service factor (SF 1,1)9)

C11

O 

O 

O 

O 

– 

– 

– 

– 

Temperature class 155 (F), used acc.
to 155 (F), with increased output (10 %)9)

C12

O 

O 

O 

O 

– 

– 

– 

– 

Temperature class 155 (F), used according to 155 (F), with increased coolant tempe­rature (55 °C, 50 °C up to frame size 400)9)

C13

O 

O 

O 

O 

– 

– 

– 

– 

Colors and paint finish

Standard finish in RAL 7030 stone gray

? 

? 

? 

? 

? 

? 

? 

? 

Standard paint finish in other colors

Y53 • and standard finish RAL ….

? 

? 

? 

? 

? 

? 

? 

? 

Special finish in RAL 7030 stone gray

K26

? 

? 

? 

? 

? 

? 

? 

? 

Special finish in other colors

Y54 • and special finish RAL ….

? 

? 

? 

? 

? 

? 

? 

? 

Unpainted
(only cast iron parts primed)

K23

O 

O 

O 

O 

O 

O 

O 

O 

Special technology

Mounting of brake
(incl. brake of Stromag)

H47

– 

– 

– 

– 

O. R.

O. R.

O. R.

O. R.

Mounting of LL 861 900 220
rotary pulse encoder

H70

– 

– 

– 

– 

? 

? 

? 

? 

Mounting of HOG 10 D 1024 I
rotary pulse encoder

H73

– 

– 

– 

– 

? 

? 

? 

? 

Prepared for mounting
LL 861 900 220

H78

– 

– 

– 

– 

? 

? 

? 

? 

Prepared for mounting HOG 10 D 1024 I

H80

– 

– 

– 

– 

? 

? 

? 

? 

Mounting a special type
of rotary pulse encoder

Y70 • and encoder designa­tion

– 

– 

– 

– 

O. R.

O. R.

O. R.

O. R.

Mechanical design and degrees of protection

Low-noise version for 2-pole motors with clockwise direction of rotation

K37

? 

O

O

O

? 

O

O

O

Low-noise version for 2-pole motors with anticlockwise direction of rotation

K38

? 

O

O

O 

? 

O

O 

O 

IP56 degree of protection
(non-heavy-sea)

K52

? 

? 

? 

? 

? 

? 

? 

? 

Non-rusting screws (externally)

M27

? 

? 

? 

? 

? 

? 

? 

? 

Coolant temperature and site altitude

Coolant temperature -50 to +40 °C

D02

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

Coolant temperature -40 to +40 °C

D03

? 

? 

? 

? 

? 

? 

? 

? 

Coolant temperature -30 to +40 °C

D04

? 

? 

? 

? 

? 

? 

? 

? 

Coolant temperature 45 °C, derating 4 %10)

D11

O 

O 

O 

O 

O 

O 

O 

O 

Coolant temperature 50 °C, derating 8 %10)

D12

O 

O 

O 

O 

O 

O 

O 

O 

Coolant temperature 55 °C, derating 13 %10)

D13

O 

O 

O 

O 

O 

O 

O 

O 

Coolant temperature 60 °C,
derating 18 %10)

D14

O 

O 

O 

O 

O 

O 

O 

O 

Designs in accordance with standards and specifications

Electrical according to NEMA MG1-12

D30

? 

? 

? 

? 

? 

? 

? 

? 

Design according to UL with "Recognition Mark

D31

? 

? 

? 

? 

? 

? 

? 

? 

Canadian regulations (CSA)

D40

? 

? 

? 

? 

? 

? 

? 

? 

Design for Zones 1, 2 and 22 according to ATEX11)

Design for Zone 2 for mains-fed operation Ex nA II T3 to IEC/EN 60079-1512)13)14)

M72

? 

? 

? 

? 

– 

– 

– 

– 

Design for Zone 2 for converter-fed operation, reduced output Ex nA II T3 to IEC/EN 60079-1512)13)14)15)

M73

– 

– 

– 

– 

O. R

O.R. 

O. R

O. R

Design for Zone 22 for non-conducting dust (IP55) for mains-fed operation14)

M35

? 

? 

? 

? 

– 

– 

– 

– 

Design for Zone 22 for non-conducting dust (IP55) for converter-fed operation 13)14)

M39

– 

– 

– 

– 

? 

? 

? 

? 

VIK version14)16)

K30

? 

? 

– 

– 

O. R.

O. R.

– 

– 

Stamping of EEx nA II on VIK rating plate

C27

? 

? 

– 

– 

O. R.

O. R.

– 

– 

Bearings and lubrication

Measuring nipple for SPM shock pulse measurement for bearing inspection

G50

? 

? 

? 

? 

? 

? 

? 

? 

Bearing design for increased cantilever forces17)

K20

? 

? 

– 

– 

? 

? 

– 

– 

Balance and vibration quantity

Full key balancing

L68

? 

? 

? 

? 

? 

? 

? 

? 

Vibration quantity level A

?

? 

? 

? 

?

? 

?

?

Vibration quantity level B

K02

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

Shaft and rotor

Second standard shaft extension18)

K16

? 

? 

? 

? 

? 

? 

? 

? 

Shaft extension with standard dimensions, without featherkey way

K42

? 

? 

? 

? 

? 

? 

? 

? 

Non-standard cylindrical
shaft extension

Y55 • and identifica­tion code

? 

? 

? 

? 

? 

? 

? 

? 

Heating and ventilation

Metal external fan

K35

? 

? 

? 

? 

? 

? 

? 

? 

Anti-condensation heaters for 230 V

K45

? 

? 

? 

? 

? 

? 

? 

? 

Anti-condensation heaters for 115 V

K46

? 

? 

? 

? 

? 

? 

? 

? 

Rating plate and extra rating plates

Second rating plate, loose

K31

? 

? 

? 

? 

? 

? 

? 

? 

Extra rating plate or rating plate
with deviating rating plate data

Y80 • and identifica­tion code

? 

? 

? 

? 

? 

? 

? 

? 

Extra rating plate with identification code

Y82 • and identifica­tion code

? 

? 

? 

? 

? 

? 

? 

? 

Packaging, safety notes, documentation and test certificates

Acceptance test certificate 3.1
according to EN 10204

B02

? 

? 

? 

? 

? 

? 

? 

? 

Operating instructions on CD

B21

? 

? 

? 

? 

? 

? 

? 

? 

Document - EU manufacturer's declaration

B30

? 

? 

? 

? 

? 

? 

? 

? 

Document - Electrical data sheet

B31

? 

? 

? 

? 

? 

? 

? 

? 

Document - Order dimension drawing

B32

? 

? 

? 

? 

? 

? 

? 

? 

Document - Routine test certificate

B33

? 

? 

? 

? 

? 

? 

? 

? 

Document - Load characteristics

B37

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

Standard test (routine test) with acceptance

F01

? 

? 

? 

? 

? 

? 

? 

? 

Visual acceptance and report handover with acceptance

F03

? 

? 

? 

? 

? 

? 

? 

? 

Temperature-rise test, without acceptance

F04

? 

? 

? 

? 

? 

? 

? 

? 

Temperature-rise test, with acceptance

F05

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement during idling,
no noise analysis, no acceptance

F28

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement during idling,
no noise analysis, with acceptance

F29

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement in no-load operation, with noise analysis, without acceptance

F62

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement during idling,
with noise analysis, with acceptance

F63

? 

? 

? 

? 

? 

? 

? 

? 

Recording of current and torque curves with torque metering shaft during starting, without acceptance

F34

? 

? 

? 

? 

– 

– 

– 

– 

Recording of current and torque curves with torque metering shaft during starting, with acceptance

F35

? 

? 

? 

? 

– 

– 

– 

– 

Measurement of locked-rotor torque and current, without acceptance

F52

? 

? 

? 

? 

– 

– 

– 

– 

Measurement of locked-rotor torque and current, with acceptance

F53

? 

? 

? 

? 

– 

– 

– 

– 

Type test with heat run for horizontal motors, without acceptance

F82

? 

? 

? 

? 

? 

? 

? 

? 

Type test with heat run for horizontal motors, with acceptance

F83

? 

? 

? 

? 

? 

? 

? 

? 

Type test with heat run for vertical motors, without acceptance

F92

? 

? 

? 

? 

? 

? 

? 

? 

Type test with heat run for vertical motors, with acceptance

F93

? 

? 

? 

? 

? 

? 

? 

? 


? Standard version

O Without additional charge

• This order code only determines the price of the version - Additional plain text is required.

O. R. Possible on request

? With additional charge

v Price reduction

– Not possible

1) For 4-pole version only, type of construction IM B3, 400 V?/690 VY or 500 V? voltage (no special insulation).
Only the following short codes can be ordered in combination with the Standardline:A23, A61, A72,G50,H70,H73,K09,K10,K45,K46,K57,K83,K84,K85,L00,L97,M58 (only frame size 315),M88,Y53.

2) For appropriate tripping unit, see Catalog LV 1.

3) The standard thermistors are omitted. If PTC thermistors are required as well as KTYs or PT100s, this must be specified in the order in plain text.

4) Only possible in combination with the larger connection boxes 1XB1 621 or 1XB1 631 (order codesM58 orL00).

5) A combination with the order codesM72, M73, M35, M39, K30, C27, M88and M50is not possible. Connection box 1XP1 634 can be roteted through 4 ? 90°. Cable entry is from NDE or the delivery position. Dimension drawings available on request.

6) With 1LA8 352-2 and 1 LA8 357-4, connection box 1XB1 631 is supplied in the standard version.

7) Standard version for 1LA8 357-2 and 1LA8 357-4.

8) VIK version is not possible..

9) Not possible for converter operation.

10) Site altitude up to 1000 m above sea level.

11 ) Explosion-protected encoders are available on request.

12 ) Only admissable for use in accordance with temperature class B. PTC ther­mistors for temperature class B are included. For compliance with temper­ature class B, derating is necessary in the case of converter-fed operation in Zones 2 and 22. Derating data are available on request

13) These motors do not have a rated voltage range stamped on the rating plate.

14) For optionsK30, M35, M39, M72, M73an additional metal external fan order codeK35 must be ordered.

15)In the order, the „Speed range and torque characteristic“ must be specified in plain text. A system test is necessary for M ? constant

16) The VIK version comprises Zone 2 for mains-fed operation – without EEx nA II marking on rating plate. For 2-pole motors of frame size 315, the low-noise version is also required.
Order code K37 orK38and additionaly the metal external fan order codeK35. Note the specified output and dimensions. For 1LA8 353 to 1LA8 357 motors, the connection box cannot be rotated by 4 x 90°.

17) Not possible for 2-pole motors and motors of vertical type of construction.

18)Please inquire in the case of 2-pole motors and motors in vertical type of construction

Special versions

Additional identifica­tion code with order code and plain text if necessary

Motor type frame size








315

355

400

450

Forced-air cooled motors with externally-mounted fan for converter-fed operation 1PQ8

1PQ8Converter-fed operation

Standardline

Standardline version

B20

– 

– 

– 

– 

Motor protection

Motor protection with PTC thermistors with 6 embedded temperature sensors for alarm and tripping1)

A12

? 

? 

? 

? 

Motor temperature detection
with embedded temperature sensor KTY 84-1302)

A23

O 

O 

O 

O 

Installation of 6 PT 100 resistance thermometers in stator winding2)

A61

? 

? 

? 

? 

Installation of 2 PT 100 screw-in resistance thermometers (basic circuit) for rolling-contact bearings

A72

? 

? 

? 

? 

Motor connection and connection boxes

Two-part plate on connection box

K06

O.R. 

O.R.  

 O.R. 

O.R. 

Undrilled entry plate

L01

O 3)

O 

O 

O 

Connection box on RHS

K09

? 

? 

? 

? 

Connection box on LHS

K10

O 

O 

O 

O 

Connection box above (1XB1 634 connection box)4)

K11

? 

? 

? 

? 

Cable entry, maximum configuration

K57

? 

? 

? 

? 

Rotation of the connection box
through 90°, entry from DE

K83

O 

O 

O 

O 

Rotation of the connection box
through 90°, entry from NDE

K84

O 

O 

O 

O 

Rotation of the connection box through 180°

K85

O 

O 

O 

O 

Larger connection box (1XB1 621 connection box)

M58

? 

? 5)

–  

? 

Larger connection box
(1XB1 631 connection box)

L00

? 

? 6)

? 

? 

6 cables protruding, 1.5 m long

L48

O. R.

O. R.

O. R.

O. R.

6 cables protruding, 3 m long

L49

O. R.

O. R.

O. R.

O. R.

Auxiliary connection box 1XB9 016 (cast-iron)

M50

? 

? 

? 

? 

Auxiliary connection box 1XB3 020

L97

? 

? 

? 

? 

Auxiliary connection box 1XB9 014
(aluminum)

M88

? 

? 

? 

? 

Connection box on NDE

M64

? 

? 

? 

? 

Windings and insulation

Temperature class 155 (F), used acc. To 155 (F),
with service factor (SF 1,1)7)

C11

– 

– 

– 

– 

Temperature class 155 (F), used acc. To 155 (F),
with increased output (10 %)7)

C12

– 

– 

– 

– 

Temperature class 155 (F), used according to 155 (F), with increased coolant temperature (55 °C, 50 °C up to frame size 400)7)

C13

– 

– 

– 

– 

Colors and paint finish

Standard finish in RAL 7030 stone gray

? 

? 

? 

? 

Standard paint finish in other colors

Y53 • and special finish RAL ….

? 

? 

? 

? 

Special finish in RAL 7030 stone gray

K26

? 

? 

? 

? 

Special finish in other colors

Y54 • and special finish RAL ….

? 

? 

? 

? 

Unpainted (only cast-iron parts primed)

K23

? 

? 

? 

? 

Special technology

Mounting of brake
(incl. brake of Stromag)

H47

O. R.

O. R.

O. R.

O. R.

Mounting of LL 861 900 220
rotary pulse encoder

H70

? 

? 

? 

? 

Mounting of HOG 10 D 1024 I
rotary pulse encoder

H73

? 

? 

? 

? 

Prepared for mounting
LL 861 900 220

H78

? 

? 

? 

? 

Prepared for mounting HOG 10 D 1024 I

H80

? 

? 

? 

? 

Mounting a special type
of rotary pulse encoder

Y70 • and encoder designation

O. R.

O. R.

O. R.

O. R.

Mechanical design and degrees of protection

Low-noise version for 2-pole motors with clockwise direction of rotation

K37

 O

O

O 

O

Low-noise version for 2-pole motors with anticlockwise direction of rotation

K38

 O

 O

O

O

IP56 degree of protection
(non-heavy-sea)

K52

O. R.

O. R.

O. R.

O. R.

Non-rusting screws (externally)8)

M27

? 

? 

? 

? 

Coolant temperature and site altitude

Coolant temperature -50 to +40 °C

D02

O. R.

O. R.

O. R.

O. R.

Coolant temperature -40 to +40 °C

D03

O. R.

O. R.

O. R.

O. R.

Coolant temperature -30 to +40 °C

D04

O. R.

O. R.

O. R.

O. R.

Coolant temperature 45 °C, derating 4 %9)

D11

O 

O 

O 

O 

Coolant temperature 50 °C, derating 8 %9)

D12

O 

O 

O 

O 

Coolant temperature 55 °C, derating 13 %9)

D13

O 

O 

O 

O 

Coolant temperature 60 °C, derating 18 %9)

D14

O. R.

O. R.

O. R.

O. R.

Designs in accordance with standards and specifications

Electrical according to NEMA MG1-1210)

D30

? 

? 

? 

? 

Design according to UL with "Recognition Mark

D31

? 

? 

? 

? 

Canadian regulations (CSA)

D40

? 

? 

? 

? 

Design for Zones 2 and 22 according to ATEX11)

Design for Zone 2 for mains-fed operation EEx nA II T3
to IEC/EN 60079-1512) 13)

M72

– 

– 

– 

– 

Design for Zone 2 for converter-fed operation, reduced output EEx nA II T3 to IEC/EN 60079-1512)13) 14) 15)

M73

O. R.

O. R.

O. R.

O. R.

Design for Zone 22 for non-conducting dust (IP55) for mains-fed operation13)

M35

– 

– 

– 

– 

Design for Zone 22 for non-conducting dust (IP55) for converter-fed operation 13)

M39

– 

– 

– 

– 

VIK version

K30

– 

– 

– 

– 

Stamping of Ex nA II on VIK rating plate

C27

– 

– 

– 

– 

Bearings and lubrication

Measuring nipple for SPM shock pulse measurement for bearing inspection

G50

? 

? 

? 

? 

Bearing design for increased cantilever forces16)

K20

? 

? 

– 

– 

Balance and vibration quantity

Full key balancing

L68

? 

? 

? 

? 

Vibration quantity level A

 ?

?

?

 ?

Vibrationquantity level B

K02

O. R.

O. R.

O. R.

O. R.

Shaft and rotor

Metal external fan

K35

? 

? 

? 

? 

Second standard shaft extension

K16

– 

– 

– 

– 

Shaft extension with standard dimensions, without featherkey way

K42

? 

? 

? 

? 

Non-standard cylindrical
shaft extension

Y55 • and identifica­tion code

? 

? 

? 

? 

Heating and ventilation

Anti-condensation heaters for 230 V

K45

? 

? 

? 

? 

Anti-condensation heaters for 115 V

K46

? 

? 

? 

? 

Separately driven fan with non-standard voltage and/or frequency17)

Y81 • and identifica­tion code

? 

? 

? 

? 

Rating plate and extra rating plates

Second rating plate, loose

K31

? 

? 

? 

? 

Extra rating plate or rating plate
with deviating rating plate data

Y80 • and identifica­tion code

? 

? 

? 

? 

Extra rating plate with identification code

Y82 • and identifica­tion code

? 

? 

? 

? 

Packaging, safety notes, documentation and test certificates

Acceptance test certificate 3.1 according to EN 10204

B02

? 

? 

? 

? 

Operating instructions on CD

B21

? 

? 

? 

? 

Document - EU manufacturer's declaration

B30

? 

? 

? 

? 

Document - Electrical data sheet

B31

? 

? 

? 

? 

Document - Order dimension drawing

B32

? 

? 

? 

? 

Document - Routine test certificate

B33

? 

? 

? 

? 

Document - Load characteristics

B37

O. R.

O. R.

O. R.

O. R.

Standard test (routine test) with acceptance

F01

? 

? 

? 

? 

Visual acceptance and report handover with acceptance

F03

? 

? 

? 

? 

Temperature-rise test, without acceptance

F04

? 

? 

? 

? 

Temperature-rise test, with acceptance

F05

? 

? 

? 

? 

Noise measurement during idling,
no noise analysis, no acceptance

F28

? 

? 

? 

? 

Noise measurement during idling,
no noise analysis, with acceptance

F29

? 

? 

? 

? 

Noise measurement in no-load operation, with noise analysis, without acceptance

F62

? 

? 

? 

? 

Noise measurement during idling,
with noise analysis, with acceptance

F63

? 

? 

? 

? 

Recording of current and torque curves with torque metering shaft during starting, without acceptance

F34

– 

– 

– 

– 

Recording of current and torque curves with torque metering shaft during starting, with acceptance

F35

– 

– 

– 

– 

Measurement of locked-rotor torque and current, without acceptance

F52

– 

– 

– 

– 

Measurement of locked-rotor torque and current, with acceptance

F53

– 

– 

– 

– 

Type test with heat run for horizontal motors, without acceptance

F82

? 

? 

? 

? 

Type test with heat run for horizontal motors, with acceptance

F83

? 

? 

? 

? 

Type test with heat run for vertical motors, without acceptance

F92

? 

? 

? 

? 

Type test with heat run for vertical motors, with acceptance

F93

? 

? 

? 

? 


? Standard version

O Without additional charge

• This order code only determines the price of the version - Additional plain text is required.

O. R. Possible on request

? With additional charge

– Not possible

1) For appropriate tripping unit, see Catalog LV 1.

2) The standard thermistors are omitted. If PTC thermistors are required as well as KTYs or PT100s, this must be specified in the order in plain text.

3) Only possible in combination with the larger connection boxes 1XB1 621 or 1XB1 631 (order codesM58 orL00).

4) A combination with the order codesM72,M73,M35,M39,K30,C27,M88 andM50 is not possible. Connection box 1XP1 634 can be rotated through 4 x 90°. Cable entry is from NDE or the delivery position. Dimension draw­ings available on request..

5) With 1PQ8 357-2 and 1PQ8 357-4, connection box 1XB1 631 is supplied in the standard version

6) Standard version for 1PQ8 357-2 and 1PQ8 357-4.

7) Not possible for converter operation.

8) Only possible for main motor – Not possible for separately driven fan.

9) Site altitude up to 1000 m above sea level.

10 ) Only possible for main motor – Not possible for separately driven fan.

11) Explosion-protected encoders are available on request.

12 ) Only admissible for use in accordance with temperature class 130 (B). PTC ther­mistors for temperature class 130 (B) are included. For compliance with temper­ature class 130 (B), derating is necessary in the case of converter-fed operation in Zones 2 and 22. Derating data are available on request.

13) These motors do not have a rated voltage range stamped on the rating plate

14) In the order, the "Speed range and torque characteristic" must be speci­fied in plain text. A system test is necessary for

M = constant

15) For optionsM73an additional metal external fan order codeK35 must be ordered.

16) Not possible for 2-pole motors and motors of vertical type of construction.

17) When ordering, specifiy in plain text: Voltage, frequency and circuit.

.

Special versions

Additional identifica­tion code with order code and plain text if necessary

Motor type frame size








315

355

400

450

315

355

400

450

Self-ventilated motors with through ventilation for mains-fed and converter-fed operation

1LL8
Mains-fed operation

1LL8
Converter-fed operation

Standardline

Standardline version

B20

– 

– 

– 

– 

– 

– 

– 

– 

Motor protection

Motor protection with PTC thermistors with 6 embedded temperature sensors for alarm and tripping1)

A12

? 

? 

? 

? 

? 

? 

? 

? 

Motor temperature detection
with embedded temperature sensor KTY 84-1302)

A23

O 

O 

O 

O 

O 

O 

O 

O 

Installation of 6 PT 100 resistance thermometers in stator winding2)

A61

? 

? 

? 

? 

? 

? 

? 

? 

Installation of 2 PT 100 screw-in resistance thermometers (basic circuit) for rolling-contact bearings

A72

? 

? 

? 

? 

? 

? 

? 

? 

Motor connection and connection boxes

Two-part plate on connection box

K06

? 

? 

? 

? 

a. A.

a. A.

a. A.

a. A.

Undrilled entry plate

L01

? 

? 

? 

? 

? 

? 

? 

? 

Connection box on RHS

K09

? 

? 

? 

? 

? 

? 

? 

? 

Connection box on LHS

K10

O 

O 

O 

O 

O 

O 

O 

O 

Connection box above
(1XB1 634 connection box)3)

K11

? 

? 

? 

? 

? 

? 

? 

? 

Cable entry, maximum configuration

K57

? 

? 

? 

? 

? 

? 

? 

? 

Rotation of the connection box
through 90°, entry from DE

K83

O 

O 

O 

O 

O 

O 

O 

O 

Rotation of the connection box
through 90°, entry from NDE

K84

O 

O 

O 

O 

O 

O 

O 

O 

Rotation of connection box through 180°

K85

O 

O 

O 

O 

O 

O 

O 

O 

Larger connection box
(1XB1 621 connection box)

M58

? 

– 

– 

– 

? 

– 

– 

– 

Larger connection box
(1XB1 631 connection box)

L00

? 

? 

? 

? 

? 

? 

? 

? 

6 cables protruding, 1.5 m long

L48

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

6 cables protruding, 3 m long

L49

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

O. R.

Auxiliary connection box 1XB9 016 (cast-iron)

M50

? 

? 

? 

? 

? 

? 

? 

? 

Auxiliary connection box 1XB3 020

L97

? 

? 

? 

? 

? 

? 

? 

? 

Auxiliary connection box 1XB9 014
(aluminum)

M88

? 

? 

? 

? 

? 

? 

? 

? 

Connection box on NDE

M64

? 

? 

? 

? 

? 

? 

? 

? 

Windings and insulation

Temperature class 155 (F), used acc. to 155 (F), with service factor (SF 1,1)4)

C11

? 

? 

? 

? 

– 

– 

– 

– 

Temperature class 155 (F), used acc. To 155 (F), with increased output (10 %)4)

C12

? 

? 

? 

? 

– 

– 

– 

– 

Temperature class 155 (F), used according to 155 (F), with increased coolant temperature (55 °C, 50 °C to frame size 400)4)

C13

? 

? 

? 

? 

– 

– 

– 

– 

Colors and paint finish

Standard finish in RAL 7030 stone gray

? 

? 

? 

? 

? 

? 

? 

? 

Standard paint finish in other colors

Y53 • and special finish RAL ….

? 

? 

? 

? 

? 

? 

? 

? 

Special finish in RAL 7030 stone gray

K26

? 

? 

? 

? 

? 

? 

? 

? 

Special finish in other colors

Y54 • and special finish RAL ….

? 

? 

? 

? 

? 

? 

? 

? 

Unpainted (only cast-iron parts primed)

K23

? 

? 

? 

? 

? 

? 

? 

? 

Special technology

Mounting of brake (incl. brake of Stromag)

H47

– 

– 

– 

– 

– 

– 

– 

– 

Mounting of LL 861 900 220 rotary pulse encoder

H70

– 

– 

– 

– 

? 

? 

? 

? 

Mounting of HOG 10 D 1024 I rotary pulse encoder

H73

– 

– 

– 

– 

? 

? 

? 

? 

Prepared for mounting LL 861 900 220

H78

– 

– 

– 

– 

? 

? 

? 

? 

Prepared for mounting HOG 10 D 1024 I

H80

– 

– 

– 

– 

? 

? 

? 

? 

Mounting a special type of rotary pulse encoder

Y70 • and encoder designa­tion

– 

– 

– 

– 

O. R.

O. R.

O. R.

O. R.

Mechanical design and degrees of protection

Low-noise version for 2-pole motors with clockwise direction of rotation

K37

? 

O

O 

O 

? 

O 

O

O

Low-noise version for 2-pole motors with anticlockwise direction of rotation

K38

? 

O

O

O

? 

O 

O

O

IP56 degree of protection
(non-heavy-sea)

K52

– 

– 

– 

– 

– 

– 

– 

– 

Non-rusting screws (externally)

M27

? 

? 

? 

? 

? 

? 

? 

? 

Coolant temperature and site altitude

Coolant temperature -50 to +40 °C

D02

– 

– 

– 

– 

– 

– 

– 

– 

Coolant temperature -40 to +40 °C

D03

– 

– 

– 

– 

– 

– 

– 

– 

Coolant temperature -30 to +40 °C

D04

– 

– 

– 

– 

– 

– 

– 

– 

Coolant temperature 45 °C, derating 4 %5)

D11

O 

O 

O 

O 

O 

O 

O 

O 

Coolant temperature 50 °C, derating 8 %5)

D12

O 

O 

O 

O 

O 

O 

O 

O 

Coolant temperature 55 °C, derating 13 %5)

D13

O 

O 

O 

O 

O 

O 

O 

O 

Coolant temperature 60 °C, derating 18 %5)

D14

O 

O 

O 

O 

O 

O 

O 

O 

Designs in accordance with standards and specifications

Electrical according to NEMA MG1-12

D30

? 

? 

? 

? 

? 

? 

? 

? 

Design according to UL with “Recognition Mark“

D31

? 

? 

? 

? 

? 

? 

? 

? 

VIK version

K30

– 

– 

– 

– 

– 

– 

– 

– 

Canadian regulations (CSA)

D40

? 

? 

? 

? 

? 

? 

? 

? 

Designs for Zones 2 and 22 according to ATEX

Design for Zone 2 for mains-fed operation Ex nA II T3 to IEC/EN 60079-15

M72

– 

– 

– 

– 

– 

– 

– 

– 

Design for Zone 2 for converter-fed operation, reduced output Ex nA II T3 to IEC/EN 60079-15

M73

– 

– 

– 

– 

– 

– 

– 

– 

Design for Zone 22 for non-conducting dust (IP55) for mains-fed operation

M35

– 

– 

– 

– 

– 

– 

– 

– 

Design for Zone 22 for non-conducting dust (IP55) for converter-fed operation 

M39

– 

– 

– 

– 

– 

– 

– 

– 

Stamping of Ex nA on VIK rating plate

C27

– 

– 

– 

– 

– 

– 

– 

– 

Bearings and lubrication

Measuring nipple for SPM shock pulse measurement for bearing inspection

G50

? 

? 

? 

? 

? 

? 

? 

? 

Bearing design for increased cantilever forces

K20

– 

– 

– 

– 

– 

– 

– 

– 

Balance and vibration quantity

Full key balancing

L68

? 

? 

? 

? 

? 

? 

? 

? 

Vibration quantity level A

?

?

?

? 

?

?

?

? 

Vibration quantity level B

K02

a. A.

a. A.

a. A.

a. A.

a. A.

a. A.

a. A.

a. A.

Shaft and rotor

Second standard shaft extension6)

K16

? 

? 

? 

? 

? 

? 

? 

? 

Shaft extension with standard dimensions, without featherkey way

K42

? 

? 

? 

? 

? 

? 

? 

? 

Non-standard cylindrical shaft extension

Y55 • and identification code

? 

? 

? 

? 

? 

? 

? 

? 

Heating and ventilation

Metal external fan

K35

? 

? 

? 

? 

? 

? 

? 

? 

Anti-condensation heaters for 230 V

K45

? 

? 

? 

? 

? 

? 

? 

? 

Anti-condensation heaters for 115 V

K46

? 

? 

? 

? 

? 

? 

? 

? 

Sheet metal fan cover

L36

? 

? 

? 

? 

? 

? 

? 

? 

Rating plate and extra rating plates

Second rating plate, loose

K31

? 

? 

? 

? 

? 

? 

? 

? 

Extra rating plate or rating plate
with deviating rating plate data

Y80 • and identifica­tion code

? 

? 

? 

? 

? 

? 

? 

? 

Extra rating plate with identification code

Y82 • and identifica­tion code

? 

? 

? 

? 

? 

? 

? 

? 

Packaging, safety notes, documentation and test certificates

Acceptance test certificate 3.1
according to EN 10204

B02

? 

? 

? 

? 

? 

? 

? 

? 

Operating instructions on CD

B21

? 

? 

? 

? 

? 

? 

? 

? 

Document - EU manufacturer's declaration

B30

? 

? 

? 

? 

? 

? 

? 

? 

Document - Electrical data sheet

B31

? 

? 

? 

? 

? 

? 

? 

? 

Document - Order dimension drawing

B32

? 

? 

? 

? 

? 

? 

? 

? 

Document - Routine test certificate

B33

? 

? 

? 

? 

? 

? 

? 

? 

Document - Load characteristics

B37

a. A.

a. A.

a. A.

a. A.

a. A.

a. A.

a. A.

a. A.

Standard test (routine test) with acceptance

F01

? 

? 

? 

? 

? 

? 

? 

? 

Visual acceptance and report handover with acceptance

F03

? 

? 

? 

? 

? 

? 

? 

? 

Temperature-rise test, without acceptance

F04

? 

? 

? 

? 

? 

? 

? 

? 

Temperature-rise test, with acceptance

F05

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement during idling,
no noise analysis, no acceptance

F28

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement during idling,
no noise analysis, with acceptance

F29

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement in no-load operation, with noise analysis, without acceptance

F62

? 

? 

? 

? 

? 

? 

? 

? 

Noise measurement during idling,
with noise analysis, with acceptance

F63

? 

? 

? 

? 

? 

? 

? 

? 

Recording of current and torque curves with torque metering shaft during starting, without acceptance

F34

? 

? 

? 

? 

– 

– 

– 

– 

Recording of current and torque curves with torque metering shaft during starting, with acceptance

F35

? 

? 

? 

? 

– 

– 

– 

– 

Measurement of locked-rotor torque and current, without acceptance

F52

? 

? 

? 

? 

– 

– 

– 

– 

Measurement of locked-rotor torque and current, with acceptance

F53

? 

? 

? 

? 

– 

– 

– 

– 

Type test with heat run for horizontal motors, without acceptance

F82

? 

? 

? 

? 

? 

? 

? 

? 

Type test with heat run for horizontal motors, with acceptance

F83

? 

? 

? 

? 

? 

? 

? 

? 

Type test with heat run for vertical motors, without acceptance

F92

? 

? 

? 

? 

? 

? 

? 

? 

Type test with heat run for vertical motors, with acceptance

F93

? 

? 

? 

? 

? 

? 

? 

? 


? Standard version

O Without additional charge

• This order code only determines the price of the version - Additional plain text is required.

O. R. Possible on request

? With additional charge

– Not possible

1) For appropriate tripping unit, see Catalog LV 1.

2) The standard thermistors are omitted. If PTC thermistors are required as well as KTYs or PT100s, this must be specified in the order in plain text.

3) A combination with the order codesM72,M73,M35,M39,K30,C27,M88 andM50 is not possible. Connection box 1XP1 634 can be rotated through 4 x 90°. Cable entry is from NDE or the delivery position. Dimension draw­ings available on request.

4) Not possible for converter operation.

5) Site altitude 1000 m above sea level

6) Please inquire in the case of 2-pole motors and motors in vertical type of construction.


Êàòàëîã îáîðóäîâàíèÿ

Ïðèâîäíàÿ òåõíèêà

Äâèãàòåëè ïåðåìåííîãî òîêà

Íèçêîâîëüòíûå äâèãàòåëè

Low-Voltage Motors - IEC Squirrel-Cage Motors

1LE1 motor generation

Standard motors up to frame size 315 L

Non-standard motors frame size 315 and above

Orientation

Self-ventilated motors, mains-fed operation, cast-iron series 1LA8

Self-ventilated motors, converter-fed operation, cast-iron series 1LA8

Forced air-cooled, externally-mounted fan, cast-iron series 1PQ8

Self-ventilated, through ventilation for mains-fed operation, 1LL8

Self-ventilated, through ventilation for converter-fed operation, 1LL8

Special versions

Accessories and spare parts

Dimensions

Explosion-proof motors

Motors operating with frequency converters

Pump motors

Fan motors

Compressor motors

Smoke-extraction motors

Marine motors

Ñèíõðîííûå äâèãàòåëè ñ âîçáóæäåíèåì îò ïîñòîÿííûìõ ìàãíèòîâ

Àñèíõðîííûå ñåðâîäâèãàòåëè/äâèãàòåëè ãëàâíîãî äâèæåíèÿ

Ñèíõðîííûå äâèãàòåëè

Ìîìåíòíûå äâèãàòåëè 1FW

Ìîòîð-øïèíäåëü 2SP1 ECS

Ëèíåéíûå äâèãàòåëè

Ëèíåéíûå äâèãàòåëè 1FN

Øàãîâûå äâèãàòåëè 1FL3 SIMOSTEP

Ñèñòåìû èçìåðåíèÿ

Ñòîÿíî÷íûé òîðìîç

Àñèíõðîííûå äâèãàòåëè - ñòàíäàðòíàÿ ëèíèÿ

Äâèãàòåëè ïîñòîÿííîãî òîêà

Äåöåíòðàëèçîâàííàÿ ïðèâîäíàÿ òåõíèêà

Ïðåîáðàçîâàòåëè

Ïðåîáðàçîâàòåëè ïîñòîÿííîãî òîêà

Èíñòðóìåíòàëüíîå ïðîãðàììíîå îáåñïå÷åíèå

Äîïîëíèòåëüíûå êîìïîíåíòû

Òåõíèêà àâòîìàòèçàöèè

Êîììóíèêàöèè è ñåòè

Íèçêîâîëüòíàÿ êîììóòàöèîííàÿ òåõíèêà

Ýëåêòðîóñòàíîâî÷íàÿ òåõíèêà

Ñïåöèàëèçèðîâàííûå ñåíñîðû

Áëîêè ïèòàíèÿ

Òåõíîëîãèÿ áåçîïàñíîñòè

Ñèñòåìíûå ðåøåíèÿ è ïðîäóêòû äëÿ îòðàñëåé

Ñåðâèñ

Àâòîìàòèçàöèÿ ïðîöåññà

... è âñå, ÷òî Âàì åùå íåîáõîäèìî


  © ÎÎÎ "ÑÊ ÝÍÅÐÃÎ" 2007-2022
  (4872) 700-366  skenergo@mail.ru
ßíäåêñ.Ìåòðèêà