Order No. supplements
Motor type |
Penultimate position: Voltage code |
Final position: Type of construction code | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
50 Hz |
Without flange |
With flange |
With standard flange |
With special flange | |||||||||
230 V?/400 VY |
400 V?/690 VY |
500 VY |
500 V? |
IM B3/6/7/8, |
IM B5, |
IM V1 without protective cover 2)3) |
IM V1 without protective cover 3)4) |
IM B35 |
IM B14, |
IM B34 |
IM B14, | ||
1 |
6 |
3 |
5 |
0 |
1 |
1 |
8 |
4 |
6 |
2 |
7 |
3 | |
1LA7 08 . ? . . . ?? |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
? |
? |
? |
1LA7 09 . ? . . . ?? |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
? |
? |
? |
1LA7 10 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
? |
? |
1LA7 11 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
? |
? |
1LA7 13 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
? |
? |
1LA7 16 . ? . . . ?? |
O |
O |
O |
O |
? |
? |
? |
? |
? |
? |
? |
? |
? |
1LA5 18 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
? |
? |
? |
? |
? |
1LA5 20 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
? |
? |
? |
? |
? |
1LA5 22 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
? |
? |
? |
? |
? |
1LG6 25 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
? |
? |
? |
? |
? |
1LG6 28 . ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
? |
? |
? |
? |
? |
1LG6 310 ? . . . ?? |
O |
O |
O |
O |
? |
? 5) |
? |
? |
? |
? |
? |
? |
? |
1LG6 316 ? . . . ?? |
? |
O |
? |
O |
? 6) |
? |
? |
? |
? |
? |
? |
? |
? |
? Standard version
O Without additional charge
? With additional charge
? Not possible
Order other voltages with voltage code9 in the penultimate position and with order codeL1Y (see "Special versions" in the "Selection and ordering data" under "Voltages").
Order other types of construction with type of construction code9 in the final position and the corresponding order code (see "Special versions" in the "Selection and ordering data" under "Types of construction").
1) If motors frame sizes 180 M to 315 L in types of construction with feet IM B6, IM B7, IM V6 or IM V5 without protective cover are fixed to the wall, it is recommended that the motor feet are supported.
2) 1LA5 183-... to 1LA5 223-... motors (motor series 1LA5, frame size 180 M to 225 M) can be supplied with two additional eyebolts; specify supplement Z and order codeK32.
3) 1LG6 253-... to 1LG6 317-... motors (motor series 1LG6 frame sizes 250 M to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5, whereby one can be rotated in accordance with IM V1 or IM V3. It is important to note that stress must not be applied perpendicular to the ring plane.
4) The "Second shaft extension" option, order codeK16is not possible.
5) Type of construction IM V3 is only possible using type of construction code9 and order codeM1G.
6) Not possible for type of construction IM V6 and IM V5 without protective cover.