Overview of cooling types and degrees of protection
The modular design enables the following cooling types and degrees of protection to be derived from a basic motor module: |
|||||||
---|---|---|---|---|---|---|---|
Cooling type Designation in accordance with DIN EN 60034-6 |
With duct connection |
Degree of protection Designation in acc. with DIN EN 60034-5 |
Adaption to |
Motor type | |||
Open ventilated motors | |||||||
Suitable for use in dry indoor environments with low dust hazards | |||||||
Open-circuit ventilation through separate ventilation using axially-mounted fan unit |
IC 05 |
– |
IP23 |
Separate fan unit |
1GF | ||
Open-circuit ventilation through separate ventilation using radially-mounted fan unit |
IC 06 |
– |
IP23 |
Separate fan unit |
1GG | ||
Open-circuit ventilation through separate ventilation using separately-mounted fan unit via duct connection |
IC 17
IC 37 |
on one side (cooling air inlet) on both sides (cooling air inlet and outlet) |
IP23
IP54 |
none |
1GH | ||
T.e.f.c. motors | |||||||
Suitable for outdoor use or in very dusty and/or humid environments | |||||||
Closed-circuit ventilation through self-ventilation using air-to-air cooler |
IC A01 A61 |
– |
IP54 |
Air-to-air cooler |
1HA | ||
Surface cooling (totally enclosed through natural ventilation) |
IC 0041 |
– |
IP54 |
none |
1HC | ||
Closed-circuit ventilation through separate ventilation using air-to-air cooler |
IC A06 A66 |
– |
IP54 |
Air-to-air cooler, separate fan unit |
1HQ | ||
Closed-circuit ventilation through separate ventilation using air-to-water cooler |
IC W37 A86 |
– |
IP54 |
Air-to-water cooler, separate fan unit |
1HS |