General features | |
Design | Built-in unit |
Fronts | |
Display diagonal | - 22" (1 680 x 1 050) 16:10,
- 24" (1 920 x 1 080) 16:9 and
- 24" WU (1 920 x 1 200) 16:10
|
Resolution | 1 680 x 1 050 or 1 920 x 1 080 or 1 920 x 1 200 |
Number of colors | 16.7 million |
Brightness | - Standard display 300 cd/mІ
|
Contrast | 1 000:1 |
MTBF backlight | LED backlight approx. 50 000 h |
Single-touch | ResistiveНѕ 5-wire glass or membrane touch |
Computing unit | |
Processor | ATOM E3845, Intel Bay Trail (BT)Нѕ 1.91 GHzНѕ Quad Core |
Main memory | 4 GB RAM |
Operating system | |
Windows Embedded Standard 7 (64-bit) | Pre-installed |
Windows 7 Ultimate (64-bit) | Pre-installed |
Drives | |
Mass storage | 32 GB SSD, 64 GB SSD, 128 GB SSD MLC |
Interfaces | |
Ethernet | - 10/100BaseTX - copper Ethernet or
- 2x 10/100BaseTX - 2x copper Ethernet or
- 1000BaseSX - Fiber Optic Ethernet or
- 1000BaseLX - Fiber Optic Ethernet or
- 100BaseFX - Fiber Optic Ethernet
|
USB | 2 x USB (Ex ia), 1 x USB (Ex e), 2 x USB (Ex ia) (keyboard, pointer instrument) |
Serial | 1 x RS 232 (Ex e) |
Audio | 1 x audio line out (Ex e) |
Barcode | Optionally via USB |
Bluetooth | Optionally via USB |
Power supply | |
| - Yes (100 – 240 V AC)
- Yes; optional
|
Ambient conditions | |
Temperature | - -20 °C ... +55 °C
- -30 °C ... +55 °C with heater
- Storage -40 °C ... +70 °C
|
Relative humidity during operation | +55 °C (±2 °C) ≥ 95%, according to IEC 60068-2-30 : 2005 |
Degree of protection | IP66 front, IP65 rearНѕ optionally according to GMP |
Vibration | Operation: 5 to 13.2 Hz: ± 1 mm 13.2 to 100 Hz: ± 0.7 g |
Shock | Operation: 15 g / 11 ms |
Miscellaneous | |
Power consumption at 24 V DC | Typ. 50 W / 100 W at O30 / max. 150 W (typ. 170 BTU / 341 BTU at O30 / max. 510 BTU) |
Weight / Size | |
Weights | |
Dimensions (W x H x D) | - 22": 660 mm x 475 mm x 110 mm
- 24": 660 mm x 475 mm x 110 mm
|
Approvals | |
IECEx | - Ex e q [ia op is Ga] IIC T4 GbНѕ
- Ex tb IIIC [ia op is Da] IP65 T110 °C Db
|
ATEX | - II 2(1) G Ex e q [ia op is Ga] IIC T4 Gb II 2(1) D
- Ex tb IIIC [ia op is Da] IP65 T110 °C Db
|
NEC | Class I, Zone 1 AEx e q [ia] IIC T4 Gb |
CEC | Ex e q [ia] IIC T4 Gb Class I, Division 2 |
TR | - 1Ex e q [ia op is Ga] IIC T4 Gb X
- Ex tb IIIC [ia op is Da] IP65 T110 °C Db
|
KGS | - Ex e q IIC T4
- Ex tb IIIC IP64 T110 °C
- Ex ia IIC T4
- Ex ia IIIB T110 °C
|