Article number

6AG1124-0QC13-2AX0

SIPLUS HMI TP1500 Comfort Outdoor

General information

 

Product type designation

SIPLUS HMI TP1500 Comfort Outdoor

Display

 

Design of display

TFT, bonded, daylight-readable

Screen diagonal

15.4 in

Display width

331.2 mm

Display height

207 mm

Number of colors

16 777 216

Resolution (pixels)

 

  • в—Џ Horizontal image resolution

1 280 Pixel

  • в—Џ Vertical image resolution

800 Pixel

Backlighting

 

  • в—Џ MTBF backlighting (at 25 °C)

50 000 h

  • в—Џ Backlight dimmable

Yes; LED, can be dimmed manually or automatically

Keyboard fonts

 

  • в—Џ Function keys

  • — Number of function keys

0

  • в—Џ Keys with LED

No

  • в—Џ System keys

No

  • в—Џ Numeric keyboard

Yes; Onscreen keyboard

  • в—Џ alphanumeric keyboard

Yes; Onscreen keyboard

Touch operation

 

  • в—Џ Design as touch screen

Yes; analog, resistive

Expansions for operator control of the process

 

  • в—Џ DP direct LEDs (LEDs as S7 output I/O)

  • — F1...Fx

0

  • в—Џ Direct keys (keys as S7 input I/O)

  • — F1...Fx

0

  • в—Џ Direct keys (touch buttons as S7 input I/O)

40

Installation type/mounting

 

Mounting position

vertical

Mounting in portrait format possible

Yes

Mounting in landscape format possible

Yes

maximum permissible angle of inclination without external ventilation

35°

Supply voltage

 

Type of supply voltage

DC

Rated value (DC)

24 V

permissible range, lower limit (DC)

19.2 V

permissible range, upper limit (DC)

28.8 V

Input current

 

Current consumption (rated value)

1.3 A

Starting current inrush IІt

0.5 AІ·s

Power

 

Active power input, typ.

32 W

Processor

 

Processor type

X86

Memory

 

Flash

Yes

RAM

Yes

Memory available for user data

12 Mbyte

Type of output

 

Info LED

No

Power LED

No

Error LED

No

Acoustics

  • в—Џ Buzzer

No

  • в—Џ Speaker

Yes

Time of day

 

Clock

 

  • в—Џ Hardware clock (real-time)

Yes

  • в—Џ Software clock

No

  • в—Џ retentive

Yes; Back-up duration typically 6 weeks

  • в—Џ synchronizable

Yes

Interfaces

 

Number of industrial Ethernet interfaces

2

Number of RS 485 interfaces

1; RS 422/485 combined

Number of RS 422 interfaces

1

Number of RS 232 interfaces

0

Number of USB interfaces

2; USB 2.0

  • в—Џ USB Mini B

1; 5-pole

Number of 20 mA interfaces (TTY)

0

Number of parallel interfaces

0

Number of other interfaces

0

Number of SD card slots

2

With software interfaces

No

Industrial Ethernet

 

  • в—Џ Industrial Ethernet status LED

2

  • в—Џ Number of ports of the integrated switch

2

Protocols

 

PROFINET

Yes

Supports protocol for PROFINET IO

Yes

IRT

Yes

MRP

Yes

PROFIBUS

Yes

MPI

Yes

Protocols (Ethernet)

 

  • в—Џ TCP/IP

Yes

  • в—Џ DHCP

Yes

  • в—Џ SNMP

Yes

  • в—Џ DCP

Yes

  • в—Џ LLDP

Yes

WEB characteristics

 

  • в—Џ HTTP

Yes

  • в—Џ HTTPS

No

  • в—Џ HTML

Yes

  • в—Џ XML

No

  • в—Џ CSS

Yes

  • в—Џ Active X

No

  • в—Џ JavaScript

Yes

  • в—Џ Java VM

No

Further protocols

 

  • в—Џ CAN

No

  • в—Џ EtherNet/IP

Yes

  • в—Џ MODBUS

Yes

EMC

 

Emission of radio interference acc. to EN 55 011

 

  • в—Џ Limit class A, for use in industrial areas

Yes

  • в—Џ Limit class B, for use in residential areas

No

Degree and class of protection

 

IP (at the front)

IP66

Enclosure Type 4 at the front

Yes

Enclosure Type 4x at the front

Yes

IP (rear)

IP20

Standards, approvals, certificates

 

CE mark

Yes

Marine approval

 

  • в—Џ Compass working clearance

5 m

Ambient conditions

 

Ambient temperature during operation

 

  • в—Џ Operation (vertical installation)

  • — For vertical installation, min.

-30 °C; = Tmin

  • — For vertical installation, max.

60 °C; (55 °C, see entry ID: 64847814)

  • в—Џ Operation (max. tilt angle)

  • — At maximum tilt angle, min.

-30 °C; = Tmin

  • — At maximum tilt angle, min.

50 °C; = Tmax

  • в—Џ Operation (vertical installation, portrait format)

  • — For vertical installation, min.

-30 °C; = Tmin

  • — For vertical installation, max.

50 °C; = Tmax

  • в—Џ Operation (max. tilt angle, portrait format)

  • — At maximum tilt angle, min.

-30 °C; = Tmin

  • — At maximum tilt angle, min.

45 °C; = Tmax

Ambient temperature during storage/transportation

 

  • в—Џ min.

-30 °C

  • в—Џ max.

70 °C

Altitude during operation relating to sea level

 

  • в—Џ Ambient air temperature-barometric pressure-altitude

Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)

Relative humidity

 

  • в—Џ With condensation, tested in accordance with IEC 60068-2-38, max.

100 %; RH incl. condensation/frost (no commissioning when condensation present), vertical mounting position

Use in stationary industrial systems

 

  • — to biologically active substances according to EN 60721-3-3

Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request

  • — to chemically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

  • — to mechanically active substances according to EN 60721-3-3

Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!

Operating systems

 

proprietary

No

pre-installed operating system

 

  • в—Џ Windows CE

Yes

Configuration

 

Message indicator

Yes

Alarm system (incl. buffer and acknowledgment)

Yes

Process value display (output)

Yes

Process value default (input) possible

Yes

Recipe management

Yes

Configuration software

 

  • в—Џ STEP 7 Basic (TIA Portal)

No

  • в—Џ STEP 7 Professional (TIA Portal)

No

  • в—Џ WinCC flexible Compact

No

  • в—Џ WinCC flexible Standard

No

  • в—Џ WinCC flexible Advanced

No

  • в—Џ WinCC Basic (TIA Portal)

No

  • в—Џ WinCC Comfort (TIA Portal)

Yes

  • в—Џ WinCC Advanced (TIA Portal)

Yes

  • в—Џ WinCC Professional (TIA Portal)

Yes

Languages

 

Online languages

 

  • в—Џ Number of online/runtime languages

32

Project languages

 

  • в—Џ Languages per project

32

Functionality under WinCC (TIA Portal)

 

Libraries

Yes

Applications/options

  • в—Џ Web browser

Yes

  • в—Џ Pocket Word

Yes

  • в—Џ Pocket Excel

Yes

  • в—Џ PDF Viewer

Yes

  • в—Џ Media Player

Yes

  • в—Џ SIMATIC WinCC Sm@rtServer

Yes

  • в—Џ SIMATIC WinCC Audit

Yes

Number of Visual Basic Scripts

Yes

Task planner

  • в—Џ time-controlled

Yes

  • в—Џ task-controlled

Yes

Help system

  • в—Џ Number of characters per info text

70

Message system

 

  • в—Џ Number of alarm classes

32

  • в—Џ Bit messages

  • — Number of bit messages

4 000

  • в—Џ Analog messages

  • — Number of analog messages

200

  • в—Џ S7 alarm number procedure

Yes

  • в—Џ System messages HMI

Yes

  • в—Џ System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)

Yes

  • в—Џ Number of characters per message

80

  • в—Џ Number of process values per message

8

  • в—Џ Acknowledgment groups

Yes

  • в—Џ Message indicator

Yes

  • в—Џ Message buffer

  • — Number of entries

1 024

  • — Circulating buffer

Yes

  • — retentive

Yes

  • — maintenance-free

Yes

Recipe management

 

  • в—Џ Number of recipes

300

  • в—Џ Data records per recipe

500

  • в—Џ Entries per data record

1 000

  • в—Џ Size of internal recipe memory

2 Mbyte

  • в—Џ Recipe memory expandable

Yes

Variables

 

  • в—Џ Number of variables per device

2 048

  • в—Џ Number of variables per screen

400

  • в—Џ Limit values

Yes

  • в—Џ Multiplexing

Yes

  • в—Џ Structures

Yes

  • в—Џ Arrays

Yes

Images

 

  • в—Џ Number of configurable images

500

  • в—Џ Permanent window/default

Yes

  • в—Џ Global image

Yes

  • в—Џ Image selection by PLC

Yes

  • в—Џ Image number in the PLC

Yes

Image objects

 

  • в—Џ Number of objects per image

400

  • в—Џ Text fields

Yes

  • в—Џ I/O fields

Yes

  • в—Џ Graphic I/O fields (graphics list)

Yes

  • в—Џ Symbolic I/O fields (text list)

Yes

  • в—Џ Date/time fields

Yes

  • в—Џ Switches

Yes

  • в—Џ Buttons

Yes

  • в—Џ Graphic display

Yes

  • в—Џ Icons

Yes

  • в—Џ Geometric objects

Yes

Complex image objects

 

  • в—Џ Number of complex objects per screen

20

  • в—Џ Alarm view

Yes

  • в—Џ Trend view

Yes

  • в—Џ User view

Yes

  • в—Џ Status/control

Yes

  • в—Џ Sm@rtClient view

Yes

  • в—Џ Recipe view

Yes

  • в—Џ f(x) trend view

Yes

  • в—Џ System diagnostics view

Yes

  • в—Џ Media Player

Yes

  • в—Џ IP camera display

Yes; Webcam type see FAQs

  • в—Џ Bar graphs

Yes

  • в—Џ Sliders

Yes

  • в—Џ Pointer instruments

Yes

  • в—Џ Analog/digital clock

Yes

Lists

 

  • в—Џ Number of text lists per project

500

  • в—Џ Number of entries per text list

500

  • в—Џ Number of graphics lists per project

500

  • в—Џ Number of entries per graphics list

500

Archiving

 

  • в—Џ Number of archives per device

50

  • в—Џ Number of entries per archive

20 000

  • в—Џ Message archive

Yes

  • в—Џ Process value archive

Yes

  • в—Џ Archiving methods

  • — Sequential archive

Yes

  • — Short-term archive

Yes

  • в—Џ Memory location

  • — Memory card

Yes

  • — USB memory

Yes

  • — Ethernet

Yes

  • в—Џ Data storage format

  • — CSV

Yes

  • — TXT

Yes

  • — RDB

Yes

Security

 

  • в—Џ Number of user groups

50

  • в—Џ Number of user rights

32

  • в—Џ Number of users

50

  • в—Џ Password export/import

Yes

  • в—Џ SIMATIC Logon

Yes

Logging through printer

 

  • в—Џ Alarms

Yes

  • в—Џ Report (shift log)

Yes

  • в—Џ Hardcopy

Yes

  • в—Џ Electronic print to file

Yes; PDF, HTML

Character sets

 

  • в—Џ Keyboard fonts

  • — US English

Yes

Transfer (upload/download)

 

  • в—Џ MPI/PROFIBUS DP

Yes

  • в—Џ USB

Yes

  • в—Џ Ethernet

Yes

  • в—Џ using external storage medium

Yes; Backup/restore

Process coupling

 

  • в—Џ S7-1200

Yes

  • в—Џ S7-1500

Yes

  • в—Џ S7-200

Yes

  • в—Џ S7-300/400

Yes

  • в—Џ LOGO!

Yes

  • в—Џ WinAC

Yes

  • в—Џ SINUMERIK

Yes; with SINUMERIK option package

  • в—Џ SIMOTION

Yes

  • в—Џ Allen Bradley (EtherNet/IP)

Yes

  • в—Џ Allen Bradley (DF1)

Yes

  • в—Џ Mitsubishi (MC TCP/IP)

Yes

  • в—Џ Mitsubishi (FX)

Yes

  • в—Џ OMRON (FINS TCP)

No

  • в—Џ OMRON (LINK/Multilink)

Yes

  • в—Џ Modicon (Modbus TCP/IP)

Yes

  • в—Џ Modicon (Modbus)

Yes

  • в—Џ OPC UA Client

Yes

  • в—Џ OPC UA Server

Yes

Service tools/configuration aids

 

  • в—Џ Backup/Restore manually

Yes

  • в—Џ Backup/Restore automatically

Yes

  • в—Џ Simulation

Yes

  • в—Џ Device switchover

Yes

Peripherals/Options

 

Peripherals

  • в—Џ Printer

Yes

  • в—Џ SIMATIC HMI MM memory card: Multi Media Card

Yes

  • в—Џ SIMATIC HMI SD memory card: Secure Digital memory card

Yes

  • в—Џ SIMATIC HMI CF memory card Compact Flash Card

No

  • в—Џ USB memory

Yes

  • в—Џ SIMATIC IPC USB Flashdrive (USB stick)

Yes

  • в—Џ SIMATIC HMI USB stick

Yes

  • в—Џ Network camera

Yes; See FAQ Entry ID: 62383298 and entry ID: 65647473

Mechanics/material

 

Enclosure material (front)

  • в—Џ Plastic

No

  • в—Џ Aluminum

Yes; Powder-coated, UV resistant

  • в—Џ Stainless steel

No

Dimensions

 

Width of the housing front

415 mm

Height of housing front

310 mm

Mounting cutout, width

396 mm

Mounting cutout, height

291 mm

Overall depth

77 mm

Weights

 

Weight without packaging

4 kg

Weight incl. packaging

6.2 kg

Other

 

Note:

Power, quantity structure and performance correspond to a standard 12" Comfort Panel


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания

  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru
Яндекс.Метрика