General information | | |
Product type designation | CPU 1515SP PC | CPU 1515SP PC |
HW functional status | FS05 | FS03 |
Firmware version | V2.0 | |
Installed software | | |
| No | No |
| S7-1500 Software Controller CPU 1505SP V2.0 | No |
Configuration control | | |
via dataset | Yes | |
Control elements | | |
Mode selector switch | 1 | 1 |
Supply voltage | | |
Type of supply voltage | 24 V DC | 24 V DC |
permissible range, lower limit (DC) | 19.2 V | 19.2 V |
permissible range, upper limit (DC) | 28.8 V | 28.8 V |
Reverse polarity protection | Yes | Yes |
Mains buffering | | |
| 5 ms | 5 ms |
Input current | | |
Current consumption (rated value) | 1.5 A; Full processor load, incl. ET 200SP modules and using USB | 1.5 A; Full processor load, incl. ET 200SP modules and using USB |
Current consumption (in no-load operation), typ. | 0.6 A | 0.6 A |
Inrush current, max. | 4.7 A; Rated value | 4.7 A; Rated value |
Power | | |
Active power input, max. | 36 W; incl. ET 200SP modules and using USB | 36 W; incl. ET 200SP modules and using USB |
Infeed power to the backplane bus | 8.75 W | 8.75 W |
Power loss | | |
Power loss, typ. | 15 W; without ET 200SP modules and without using USB | 15 W; without ET 200SP modules and without using USB |
Processor | | |
Processor type | Dual-Core 1 GHz, AMD G Series APU T40E | Dual-Core 1 GHz, AMD G Series APU T40E |
Memory | | |
Type of memory | DDR3-SDRAM | DDR3-SDRAM |
Main memory | 4 GB RAM | 4 GB RAM |
Flash Disk | 8 GB | |
CFast memory card | Yes; 8 GB flash memory | No |
SIMATIC memory card required | No | |
Work memory | | |
| 1 Mbyte | |
| 5 Mbyte | |
| 10 Mbyte | |
Load memory | | |
| 320 Mbyte | |
Backup | | |
| Yes; all memory areas declared retentive | |
| Yes | |
CPU processing times | | |
for bit operations, typ. | 10 ns | |
for word operations, typ. | 12 ns | |
for fixed point arithmetic, typ. | 16 ns | |
for floating point arithmetic, typ. | 64 ns | |
CPU-blocks | | |
Number of elements (total) | 6 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements | |
DB | | |
| 5 999; Number range: 1 to 65535 | |
| 5 Mbyte | |
FB | | |
| 5 998; Number range: 1 to 65535 | |
| 512 kbyte | |
FC | | |
| 5 999; Number range: 1 to 65535 | |
| 512 kbyte | |
OB | | |
| 1 048 kbyte | |
| 100 | |
| 20 | |
| 20 | |
| 20 | |
| 50 | |
| 3 | |
| 1 | |
| 2 | |
| 100 | |
| 4 | |
| 2 | |
| 1 | |
Nesting depth | | |
| 24 | |
Counters, timers and their retentivity | | |
S7 counter | | |
| 2 048 | |
Retentivity | | |
| Yes | |
IEC counter | | |
| Any (only limited by the main memory) | |
Retentivity | | |
| Yes | |
S7 times | | |
| 2 048 | |
Retentivity | | |
| Yes | |
IEC timer | | |
| Any (only limited by the main memory) | |
Retentivity | | |
| Yes | |
Data areas and their retentivity | | |
Retentive data area (incl. timers, counters, flags), max. | 410 kbyte; For storage in NVRAM; for storage in mass storage 5 242 020 bytes | |
Flag | | |
| 16 kbyte | |
| 8; 8 clock memory bits, grouped into one clock memory byte | |
Data blocks | | |
| Yes | |
| No | |
Local data | | |
| 64 kbyte; max. 16 KB per block | |
Address area | | |
Number of IO modules | 8 192 | |
I/O address area | | |
| 32 kbyte; All inputs are in the process image | |
| 32 kbyte; All outputs are in the process image | |
of which per assigned PC interface | | |
| 8 kbyte | |
| 8 kbyte | |
Subprocess images | | |
| 32 | |
Hardware configuration | | |
Integrated power supply | Yes | Yes |
Number of distributed IO systems | 20 | |
Number of DP masters | | |
| 1 | |
Rack | | |
| 64; CPU 1515SP PC + 64 modules + server module | 64; CPU + 64 modules + server module (mounting width max. 1 m) |
| 1 | 1 |
PtP CM | | |
| the number of connectable PtP CMs is only limited by the number of available slots | |
Time of day | | |
Clock | | |
| Hardware clock | Hardware clock |
| Yes; Resolution: 1 s | Yes; Resolution: 1 s |
| 6 wk; At 40 °C ambient temperature, typically | 6 wk; At 40 °C ambient temperature, typically |
| 10 s; Typ.: 2 s | 10 s; Typ.: 2 s |
Clock synchronization | | |
| Yes | |
| No | |
| Yes | |
| Yes | |
Interfaces | | |
Number of industrial Ethernet interfaces | 2 | 1 |
Number of PROFINET interfaces | 1 | 1 |
Number of PROFIBUS interfaces | 1 | |
Number of RS 485 interfaces | 1; Via CM DP module | |
Number of USB interfaces | 3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously | 3; 3x USB 2.0 on the front, 500 mA each – of which 2x 500 mA and 1x 100 mA simultaneously |
Number of SD card slots | 1 | 1 |
Video interfaces | | |
| 1x DVI-I | 1x DVI-I |
1. Interface | | |
Interface type | PROFINET | PROFINET |
automatic detection of transmission rate | Yes | Yes |
Autonegotiation | Yes | Yes |
Autocrossing | Yes | Yes |
Interface types | | |
| 2 | 2 |
| Yes | Yes |
| Yes; Via BusAdapter BA 2x RJ45 | Yes; Via BusAdapter BA 2x RJ45 |
| 100 Mbit/s | 100 Mbit/s |
| Yes | Yes |
| Yes; Applicable BusAdapter: BA 2x RJ45, BA 2x FC | |
Functionality | | |
| 88 | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
PROFINET IO Controller | | |
Services | | |
| Yes | |
| 500 µs | |
| Yes | |
| Yes | |
| Yes | |
| Yes; Max. 32 PROFINET devices | |
| 128 | |
| 64 | |
| 64 | |
| 128 | |
| 128 | |
| 8 | |
| Yes | |
| 8 | |
| The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data | |
Update time for IRT | | |
| 500 µs to 8 ms | |
| 1 ms to 16 ms | |
| 2 ms to 32 ms | |
| 4 ms to 64 ms | |
| Update time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) | |
Update time for RT | | |
| 500 µs to 256 ms | |
| 1 ms to 512 ms | |
| 2 ms to 512 ms | |
| 4 ms to 512 ms | |
PROFINET IO Device | | |
Services | | |
| No | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| 4 | |
2. Interface | | |
Interface type | Integrated Ethernet interface | Integrated Ethernet interface |
Physics | | RJ45 |
automatic detection of transmission rate | Yes | Yes |
Autonegotiation | Yes | Yes |
Autocrossing | Yes | Yes |
Interface types | | |
| 1 | 1 |
| Yes; Integrated | Yes; Integrated |
| 1 000 Mbit/s | 1 000 Mbit/s |
| No | No |
3. Interface | | |
Interface type | PROFIBUS with CM DP | |
Interface types | | |
| Yes | |
Functionality | | |
| 44 | |
| Yes | |
| Yes | |
| Yes | |
DP master | | |
| 125 | |
Services | | |
| No | |
| No | |
DP slave | | |
Services | | |
| No | |
| No | |
RS 485 | | |
| 12 Mbit/s | 12 Mbit/s |
Protocols | | |
Number of connections | | |
| 88 | |
| 10 | |
| 16 | |
SIMATIC communication | | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| 64 kbyte | |
Open IE communication | | |
| Yes | |
| 64 kbyte | |
| Yes | |
| 64 kbyte | |
| Yes | |
| 1 472 kbyte | |
| Yes | |
| Yes | |
| Yes | |
Web server | | |
| Yes; Via Windows and PROFINET interface | |
| Yes; Only via PROFINET interface | |
OPC UA | | |
| Data access (read, write, subscribe), runtime license required | |
| Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
| Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 | |
| "anonymous" or by user name & password | |
Further protocols | | |
| Yes; MODBUS TCP | |
Media redundancy | | |
| 200 ms | |
| 50 | |
S7 message functions | | |
Number of login stations for message functions, max. | 32 | |
Program alarms | Yes | |
Number of configurable program alarms | 10 000 | |
Number of simultaneously active program alarms | | |
| 1 000 | |
| 200 | |
| 160 | |
Test commissioning functions | | |
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 8 engineering systems | |
Status block | Yes; up to 8 simultaneously | |
Single step | No | |
Status/control | | |
| Yes | |
| Inputs, outputs, memory bits, DB, times, counters | |
| | |
| 200 | |
| 200 | |
Forcing | | |
| Yes | |
| Inputs, outputs | |
| 200 | |
Diagnostic buffer | | |
| Yes | |
| 1 000 | |
| 300 | |
Traces | | |
| 4 | |
| 512 kbyte | |
Interrupts/diagnostics/status information | | |
Diagnostics indication LED | | |
| Yes | |
| Yes | |
| Yes | |
Supported technology objects | | |
Motion Control | Yes | |
| 2 400 | |
| | |
| 40; per axis | |
| 80; per axis | |
| 160; per axis | |
| 80; per external encoder | |
| 20; per cam | |
| 160; per cam track | |
| 40; per probe | |
| | |
| 5 | |
| 12 | |
Controller | | |
| Yes; Universal PID controller with integrated optimization | |
| Yes; PID controller with integrated optimization for valves | |
| Yes; PID controller with integrated optimization for temperature | |
Counting and measuring | | |
| Yes | |
EMC | | |
Emission of radio interference acc. to EN 55 011 | | |
| Yes | Yes |
Standards, approvals, certificates | | |
CE mark | Yes | Yes |
Ambient conditions | | |
Ambient temperature during operation | | |
| 0 °C | 0 °C |
| 60 °C; Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load | 60 °C; Up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load |
| 0 °C; = Tmin | 0 °C; = Tmin |
| 60 °C; = Tmax; up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load | 60 °C; = Tmax; up to 60 °C with max. 32 ET 200SP modules and 3x 100 mA USB load; up to 55 °C with max. 64 ET 200SP modules and 2x max. 500 mA and 1x max. 100 mA USB load |
| 0 °C; = Tmin | 0 °C; = Tmin |
| 50 °C; = Tmax; at max. 32 ET 200SP modules and 3x 100 mA USB load | 50 °C; = Tmax; at max. 32 ET 200SP modules and 3x 100 mA USB load |
Ambient temperature during storage/transportation | | |
| -40 °C | -40 °C |
| 70 °C | 70 °C |
Altitude during operation relating to sea level | | |
| Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity | | |
| 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
Vibrations | | |
| Yes | Yes |
| Yes | Yes |
Shock testing | | |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
| Yes | Yes |
Use in stationary industrial systems | | |
| Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
| Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! | Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Operating systems | | |
Operating systems | Windows Embedded Standard 7 E 32-bit | |
Configuration | | |
Programming | | |
Programming language | | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| No | |
| Yes | |
Know-how protection | | |
| Yes | |
| Yes | |
| Yes | |
Access protection | | |
| Yes | |
| Yes | |
| Yes | |
Cycle time monitoring | | |
| adjustable minimum cycle time | |
| adjustable maximum cycle time | |
Open Development interfaces | | |
| 3.8 Mbyte | |
Peripherals/Options | | |
Peripherals | | |
| Optionally for additional mass storage | Optionally for additional mass storage |
Dimensions | | |
Width | 160 mm | 160 mm |
Height | 117 mm | 117 mm |
Depth | 75 mm | 75 mm |
Weights | | |
Weight, approx. | 0.83 kg | 0.83 kg |