Siemens
01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6AV7230-0CA20-0BA0

6AV7230-0CA20-1BA0

6AV7230-0DA20-0BA0

6AV7230-0DA20-1BA0

6AV7230-0EA20-0BA0

6AV7230-0EA20-1BA0

SIMATIC IPC377E, 12" TOUCH

SIMATIC IPC377E, 12" TOUCH

SIMATIC IPC377E, 15" TOUCH

SIMATIC IPC377E, 15" TOUCH

SIMATIC IPC377E, 19" TOUCH

SIMATIC IPC377E, 19" TOUCH

Installation type/mounting

Mounting

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Panel mount and VESA, horizontal and vertical

Design

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Panel PC, built-in unit

Supply voltage

Type of supply voltage

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

24 V DC

Mains buffering

  • Mains/voltage failure stored energy time

10ms

10ms

10ms

10ms

10ms

10ms

Processor

Processor type

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Intel Celeron N3160

Drives

Hard disk

500 GB HDD

500 GB HDD

500 GB HDD

500 GB HDD

500 GB HDD

500 GB HDD

Memory

Type of memory

DDR3L

DDR3L

DDR3L

DDR3L

DDR3L

DDR3L

Main memory

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

4 GB (pre-installed)

Capacity of main memory, max.

8Gbyte

8Gbyte

8Gbyte

8Gbyte

8Gbyte

8Gbyte

Hardware configuration

Slots

  • free slots

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

1x mPCIe (half-size), 1x mSATA (full-size)

Interfaces

Number of industrial Ethernet interfaces

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

2; 2x RJ45 (independent)

USB port

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

2x USB 2.0, 2x USB 3.0 (high current)

Video interfaces

  • Graphics interface

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

1x DisplayPort, 1x VGA

Industrial Ethernet

  • Industrial Ethernet interface

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

  • 100 Mbps

Yes

Yes

Yes

Yes

Yes

Yes

  • 1000 Mbps

Yes

Yes

Yes

Yes

Yes

Yes

Protocols

Protocols (Ethernet)

  • TCP/IP

Yes

Yes

Yes

Yes

Yes

Yes

Integrated Functions

Monitoring functions

  • Temperature monitoring

Yes

Yes

Yes

Yes

Yes

Yes

  • Watchdog

Yes

Yes

Yes

Yes

Yes

Yes

  • Status LEDs

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

POWER, HDD

  • Fan

No

No

No

No

No

No

EMC

Interference immunity against discharge of static electricity

  • Interference immunity against discharge of static electricity

6 kV contact; 8 kV air (to IEC 1000-4-2; ESD)

6 kV contact; 8 kV air (to IEC 1000-4-2; ESD)

6 kV contact; 8 kV air (to IEC 1000-4-2; ESD)

6 kV contact; 8 kV air (to IEC 1000-4-2; ESD)

6 kV contact; 8 kV air (to IEC 1000-4-2; ESD)

6 kV contact; 8 kV air (to IEC 1000-4-2; ESD)

  • Interference immunity against discharge of static electricity acc. to IEC 61000-4-2

  • Test voltage at air discharge

8kV

8kV

8kV

8kV

8kV

8kV

  • Test voltage at contact discharge

6kV

6kV

6kV

6kV

6kV

6kV

Interference immunity against high-frequency electromagnetic fields

  • Interference immunity against high frequency radiation

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

10 V/m for 80 ... 1 000 MHz, 80 % AM according to IEC 61000-4-3; 3 V/m for 1.4 ... 6 GHz, 80 % AM according to IEC 61000-4-3

Interference immunity to cable-borne interference

  • Interference immunity on supply cables

2 kV (according to IEC 61000-4-4, burst); 1 kV (according to IEC 61000-4-5, surge pulse/line to line); 2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

2 kV (according to IEC 61000-4-4, burst); 1 kV (according to IEC 61000-4-5, surge pulse/line to line); 2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

2 kV (according to IEC 61000-4-4, burst); 1 kV (according to IEC 61000-4-5, surge pulse/line to line); 2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

2 kV (according to IEC 61000-4-4, burst); 1 kV (according to IEC 61000-4-5, surge pulse/line to line); 2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

2 kV (according to IEC 61000-4-4, burst); 1 kV (according to IEC 61000-4-5, surge pulse/line to line); 2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

2 kV (according to IEC 61000-4-4, burst); 1 kV (according to IEC 61000-4-5, surge pulse/line to line); 2 kV (according to IEC 61000-4-5, surge pulse/line to ground)

  • Interference immunity on signal cables >30m

2 kV acc. to IEC 61000-4-4, burst; 2 kV acc. to IEC 61000-4-5, surge

2 kV acc. to IEC 61000-4-4, burst; 2 kV acc. to IEC 61000-4-5, surge

2 kV acc. to IEC 61000-4-4, burst; 2 kV acc. to IEC 61000-4-5, surge

2 kV acc. to IEC 61000-4-4, burst; 2 kV acc. to IEC 61000-4-5, surge

2 kV acc. to IEC 61000-4-4, burst; 2 kV acc. to IEC 61000-4-5, surge

2 kV acc. to IEC 61000-4-4, burst; 2 kV acc. to IEC 61000-4-5, surge

  • Interference immunity on signal cables < 30m

1 kV acc. to IEC 61000-4-4, Burst

1 kV acc. to IEC 61000-4-4, Burst

1 kV acc. to IEC 61000-4-4, Burst

1 kV acc. to IEC 61000-4-4, Burst

1 kV acc. to IEC 61000-4-4, Burst

1 kV acc. to IEC 61000-4-4, Burst

Interference immunity against voltage surge

  • asymmetric interference

2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

2 kV acc. to IEC 61000-4-5, surge asymmetric

  • symmetric interference

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

1 kV acc. to IEC 61000-4-5, surge symmetric

Interference immunity to magnetic fields

  • Interference immunity to magnetic fields at 50 Hz

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

100A/m; to IEC 61000-4-8

Degree and class of protection

IP (at the front)

IP65

IP65

IP65

IP65

IP65

IP65

IP (rear)

IP40

IP40

IP40

IP40

IP40

IP40

Standards, approvals, certificates

CE mark

Yes

Yes

Yes

Yes

Yes

Yes

cULus

No

No

No

No

No

No

RCM (formerly C-TICK)

Yes

Yes

Yes

Yes

Yes

Yes

EAC (formerly Gost-R)

Yes

Yes

Yes

Yes

Yes

Yes

FCC

Yes

Yes

Yes

Yes

Yes

Yes

Dust protection

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Protection against foreign bodies > 1 mm

Ambient conditions

Ambient temperature during operation

  • Ambient temperature during operation

0 to +40 C

0 to +40 C

0 to +40 C

0 to +40 C

0 to +40 C

0 to +40 C

  • min.

0C

0C

0C

0C

0C

0C

  • max.

40C

40C

40C

40C

40C

40C

Ambient temperature during storage/transportation

  • min.

-20C

-20C

-20C

-20C

-20C

-20C

  • max.

60C

60C

60C

60C

60C

60C

Relative humidity

  • Relative humidity

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 C (no condensation)

Tested according to IEC 60068-2-78, IEC 60068-2-30: Operation: 5 % to 85 % at 30 C (no condensation), storage / transport: 5 % to 95 % at 25 / 55 C (no condensation)

Vibrations

  • Vibration resistance during operation acc. to IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s; tested according to DIN IEC 60068-2-6

58 Hz to 200 Hz: 4.9 m/s; tested according to DIN IEC 60068-2-6

Shock testing

  • Shock load during operation

With HDD: 9.81 m/s, 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s, 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s, 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s, 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s, 20 ms; tested according to IEC 60068-2-27

With HDD: 9.81 m/s, 20 ms; tested according to IEC 60068-2-27

Operating systems

without operating system

Yes

Yes

Yes

Yes

Yes

Yes

Dimensions

Width

320mm

320mm

320mm

320mm

320mm

320mm

Height

225.6mm

225.6mm

225.6mm

225.6mm

225.6mm

225.6mm

Depth

95.2mm

95.2mm

95.2mm

95.2mm

95.2mm

95.2mm



















  © " " 2007-2022
  (4872) 700-366  skenergo@mail.ru
.