Siemens
СРЕДСТВА ПРОМЫШЛЕННОЙ АВТОМАТИЗАЦИИ
официальный партнер Сименс
Каталог СА01 2018
(4872) 700-366
skenergo@mail.ru

Article number

6GK5208-0HA00-2AS6

6GK5208-0HA00-2TS6

6GK5208-0HA00-2ES6

6GK5208-0UA00-5ES6

Transmission rate

 

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

10 Mbit/s, 100 Mbit/s

Interfaces for communication integrated

 

 

 

 

Number of electrical connections

 

 

 

 

  • в—Џ for network components or terminal equipment

8

8

8

8

Number of 10/100 Mbit/s M12-ports (D-coded) Integrated

8

8

8

4

  • в—Џ with PoE

4

Interfaces others

 

 

 

 

Number of electrical connections

 

 

 

 

  • в—Џ for operator console

1

1

1

1

  • в—Џ for signaling contact

1

1

1

1

  • в—Џ for power supply

1

1

1

1

  • в—Џ for redundant voltage supply

1

1

1

1

Type of electrical connection

 

 

 

 

  • в—Џ for operator console

5 pin M12 socket (A coded)

5 pin M12 socket (A coded)

5 pin M12 socket (A coded)

5 pin M12 socket (A coded)

design of the removable storage

 

 

 

 

  • в—Џ C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

 

Operating voltage of the signaling contacts

 

 

 

 

  • в—Џ at DC Rated value

24 V

24 V

24 V

54 V

Operating current of the signaling contacts

 

 

 

 

  • в—Џ at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • в—Џ external

24 V

24 V

24 V

54 V

  • в—Џ external minimum

19.2 V

19.2 V

19.2 V

46 V

  • в—Џ external maximum

28.8 V

28.8 V

28.8 V

57 V

Supply voltage 1 Rated value

  • в—Џ Consumed current 1 at rated supply voltage maximum

0.2 A

0.2 A

0.2 A

2.5 A

  • в—Џ Power loss [W] 1 Rated value

4.8 W

4.8 W

4.8 W

9 W

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Consumed current maximum

0.21 A

0.21 A

0.21 A

2.4 A

Power loss [W]

 

 

 

 

  • в—Џ at DC at 24 V

5 W

5 W

5 W

  • в—Џ maximum

9 W

Supplied active power of PSE with PoE

 

 

 

 

  • в—Џ per port maximum

120 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • в—Џ during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • в—Џ during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • в—Џ during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

 

 

  • в—Џ at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Protection class IP

IP65

IP65

IP65

IP65

Design, dimensions and weight

 

 

 

 

Design

compact

compact

compact

compact

Width

200 mm

200 mm

200 mm

200 mm

Height

200 mm

200 mm

200 mm

200 mm

Depth

49 mm

49 mm

49 mm

49 mm

Net weight

1.8 kg

1.8 kg

1.8 kg

1.8 kg

Product feature conformal coating

Yes

Yes

Material of the enclosure

Aluminum

Aluminum

Aluminum

Aluminum

Mounting type

ET200pro module carrier

ET200pro module carrier

ET200pro module carrier

ET200pro module carrier

  • в—Џ wall mounting

Yes

Yes

Yes

Yes

Product properties, functions, components general

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

50

50

50

50

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

 

Product function

 

 

 

 

  • в—Џ CLI

Yes

Yes

Yes

Yes

  • в—Џ web-based management

Yes

Yes

Yes

Yes

  • в—Џ MIB support

Yes

Yes

Yes

Yes

  • в—Џ TRAPs via email

Yes

Yes

Yes

Yes

  • в—Џ Configuration with STEP 7

Yes

Yes

Yes

Yes

  • в—Џ RMON

Yes

Yes

Yes

Yes

  • в—Џ Port mirroring

Yes

Yes

Yes

Yes

  • в—Џ multiport mirroring

Yes

Yes

Yes

Yes

  • в—Џ CoS

Yes

Yes

Yes

Yes

  • в—Џ with IRT PROFINET IO switch

No

No

No

No

  • в—Џ PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • в—Џ switch-managed

Yes

Yes

Yes

Yes

Telegram length for Ethernet maximum

1 518 byte

1 518 byte

1 518 byte

1 518 byte

Protocol is supported

 

 

 

 

  • в—Џ Telnet

Yes

Yes

Yes

Yes

  • в—Џ HTTP

Yes

Yes

Yes

Yes

  • в—Џ HTTPS

Yes

Yes

Yes

Yes

  • в—Џ TFTP

Yes

Yes

Yes

Yes

  • в—Џ FTP

Yes

Yes

Yes

Yes

  • в—Џ BOOTP

No

No

No

No

  • в—Џ DCP

Yes

Yes

Yes

Yes

  • в—Џ LLDP

Yes

Yes

Yes

Yes

  • в—Џ EtherNet/IP

Yes

Yes

Yes

Yes

  • в—Џ SNMP v1

Yes

Yes

Yes

Yes

  • в—Џ SNMP v2

Yes

Yes

Yes

Yes

  • в—Џ SNMP v3

Yes

Yes

Yes

Yes

  • в—Џ IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

 

 

 

 

  • в—Џ I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • в—Џ I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

 

Product function

 

 

 

 

  • в—Џ Port diagnostics

Yes

Yes

Yes

Yes

  • в—Џ Statistics Packet Size

Yes

Yes

Yes

Yes

  • в—Џ Statistics packet type

Yes

Yes

Yes

Yes

  • в—Џ Error statistics

Yes

Yes

Yes

Yes

  • в—Џ SysLog

Yes

Yes

Yes

Yes

  • в—Џ loopback diagnostics

Yes

Yes

Yes

Yes

Product functions VLAN

 

 

 

 

Product function

 

 

 

 

  • в—Џ VLAN - port based

Yes

Yes

Yes

Yes

  • в—Џ VLAN - protocol-based

No

No

No

No

  • в—Џ VLAN - IP-based

No

No

No

No

  • в—Џ VLAN dynamic

No

No

No

No

Number of VLANs maximum

4 094

4 094

4 094

4 094

Product functions DHCP

 

 

 

 

Product function

 

 

 

 

  • в—Џ DHCP server

Yes

Yes

Yes

Yes

  • в—Џ DHCP client

Yes

Yes

Yes

Yes

  • в—Џ DHCP Option 82

Yes

Yes

Yes

Yes

  • в—Џ DHCP Option 66

Yes

Yes

Yes

Yes

  • в—Џ DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

 

 

 

 

Product function

 

 

 

 

  • в—Џ Ring redundancy

Yes

Yes

Yes

Yes

  • в—Џ High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • в—Џ high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • в—Џ high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

 

 

 

 

  • в—Џ media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • в—Џ redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • в—Џ redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • в—Џ Passive listening

Yes

Yes

Yes

Yes

Product functions Security

 

 

 

 

Product function

 

 

 

 

  • в—Џ RADIUS client

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • в—Џ SSH

Yes

Yes

Yes

Yes

  • в—Џ SSL

Yes

Yes

Yes

Yes

Product functions Time

 

 

 

 

Product function

 

 

 

 

  • в—Џ SICLOCK support

Yes

Yes

Yes

Yes

  • в—Џ NTP-client

Yes

Yes

Yes

Yes

  • в—Џ SNTP client

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • в—Џ NTP

Yes

Yes

Yes

Yes

  • в—Џ SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • в—Џ for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • в—Џ for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • в—Џ for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • в—Џ for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • в—Џ for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • в—Џ for interference immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Standards, specifications, approvals CE

 

 

 

 

Certificate of suitability CE marking

Yes

Yes

Yes

Yes

Certificate of suitability RoHS conformity

Yes

Yes

Yes

Yes

Standards, specifications, approvals miscellaneous

 

 

 

 

Certificate of suitability

  • в—Џ C-Tick

Yes

Yes

Yes

Yes

  • в—Џ E1 approval

Yes

Yes

  • в—Џ e1 approval

Yes

Yes

  • в—Џ Railway application in accordance with EN 50155

No

No

Yes

Yes

  • в—Џ Railway application in accordance with EN 50124-1

No

No

Yes

Yes

  • в—Џ Fire protection in accordance with EN 45545-2

Yes

Yes

  • в—Џ KC approval

Yes

Yes

Yes

Yes

Standards, specifications, approvals product conformity

 

 

 

 

MTBF at 40 °C

77 y

77 y

77 y

55 y

Accessories

 

 

 

 

Product extension optional C-PLUG

Yes

Yes

Yes

Yes


Article number

6GK5216-0HA00-2AS6

6GK5216-0HA00-2TS6

6GK5216-0HA00-2ES6

6GK5216-0UA00-5ES6

Transmission rate

 

 

 

 

Transfer rate

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

10 Mbit/s, 100 Mbit/s, 1 000 Mbit/s

Interfaces for communication integrated

 

 

 

 

Number of electrical connections

 

 

 

 

  • в—Џ for network components or terminal equipment

16

16

16

16

Number of 10/100 Mbit/s M12-ports (D-coded) Integrated

12

12

12

10

  • в—Џ with PoE

2

Number of 10/100/1000 Mbit/s M12-ports (X-coded)

 

 

 

 

  • в—Џ Integrated

4

4

4

2

  • в—Џ integrated with PoE

2

Interfaces others

 

 

 

 

Number of electrical connections

 

 

 

 

  • в—Џ for operator console

1

1

1

1

  • в—Џ for signaling contact

1

1

1

1

  • в—Џ for power supply

1

1

1

1

  • в—Џ for redundant voltage supply

1

1

1

1

Type of electrical connection

 

 

 

 

  • в—Џ for operator console

5 pin M12 socket (A coded)

5 pin M12 socket (A coded)

5 pin M12 socket (A coded)

5 pin M12 socket (A coded)

design of the removable storage

 

 

 

 

  • в—Џ C-PLUG

Yes

Yes

Yes

Yes

Signal-Inputs/outputs

 

 

 

 

Operating voltage of the signaling contacts

 

 

 

 

  • в—Џ at DC Rated value

24 V

24 V

24 V

54 V

Operating current of the signaling contacts

 

 

 

 

  • в—Џ at DC maximum

0.1 A

0.1 A

0.1 A

0.1 A

Supply voltage, current consumption, power loss

 

 

 

 

Type of voltage of the supply voltage

DC

DC

DC

DC

Supply voltage

 

 

 

 

  • в—Џ external

24 V

24 V

24 V

54 V

  • в—Џ external minimum

19.2 V

19.2 V

19.2 V

46 V

  • в—Џ external maximum

28.8 V

28.8 V

28.8 V

57 V

Supply voltage 1 Rated value

  • в—Џ Consumed current 1 at rated supply voltage maximum

0.4 A

0.4 A

0.4 A

2.5 A

  • в—Џ Power loss [W] 1 Rated value

9.6 W

9.6 W

9.6 W

13 W

Product component fusing at power supply input

Yes

Yes

Yes

Yes

Consumed current maximum

0.335 A

0.335 A

0.335 A

2.5 A

Power loss [W]

 

 

 

 

  • в—Џ at DC at 24 V

8 W

8 W

8 W

  • в—Џ maximum

13 W

Supplied active power of PSE with PoE

 

 

 

 

  • в—Џ per port maximum

120 W

Permitted ambient conditions

 

 

 

 

Ambient temperature

 

 

 

 

  • в—Џ during operation

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • в—Џ during storage

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

  • в—Џ during transport

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

-40 ... +70 °C

Relative humidity

 

 

 

 

  • в—Џ at 25 °C without condensation during operation maximum

95 %

95 %

95 %

95 %

Protection class IP

IP65

IP65

IP65

IP65

Design, dimensions and weight

 

 

 

 

Design

compact

compact

compact

compact

Width

280 mm

280 mm

280 mm

280 mm

Height

200 mm

200 mm

200 mm

200 mm

Depth

49 mm

49 mm

49 mm

49 mm

Net weight

2.5 kg

2.5 kg

2.5 kg

2.5 kg

Product feature conformal coating

Yes

Yes

Material of the enclosure

Aluminum

Aluminum

Aluminum

Aluminum

Mounting type

ET200pro module carrier

ET200pro module carrier

ET200pro module carrier

ET200pro module carrier

  • в—Џ wall mounting

Yes

Yes

Yes

Yes

Product properties, functions, components general

 

 

 

 

Cascading in the case of a redundant ring at reconfiguration time of <\~0.3\~s

50

50

50

50

Cascading in cases of star topology

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

any (depending only on signal propagation time)

Product functions management, configuration

 

 

 

 

Product function

 

 

 

 

  • в—Џ CLI

Yes

Yes

Yes

Yes

  • в—Џ web-based management

Yes

Yes

Yes

Yes

  • в—Џ MIB support

Yes

Yes

Yes

Yes

  • в—Џ TRAPs via email

Yes

Yes

Yes

Yes

  • в—Џ Configuration with STEP 7

Yes

Yes

Yes

Yes

  • в—Џ RMON

Yes

Yes

Yes

Yes

  • в—Џ Port mirroring

Yes

Yes

Yes

Yes

  • в—Џ multiport mirroring

Yes

Yes

Yes

Yes

  • в—Џ CoS

Yes

Yes

Yes

Yes

  • в—Џ with IRT PROFINET IO switch

No

No

No

No

  • в—Џ PROFINET IO diagnosis

Yes

Yes

Yes

Yes

  • в—Џ switch-managed

Yes

Yes

Yes

Yes

Telegram length for Ethernet maximum

1 518 byte

1 518 byte

1 518 byte

1 518 byte

Protocol is supported

 

 

 

 

  • в—Џ Telnet

Yes

Yes

Yes

Yes

  • в—Џ HTTP

Yes

Yes

Yes

Yes

  • в—Џ HTTPS

Yes

Yes

Yes

Yes

  • в—Џ TFTP

Yes

Yes

Yes

Yes

  • в—Џ FTP

Yes

Yes

Yes

Yes

  • в—Џ BOOTP

No

No

No

No

  • в—Џ DCP

Yes

Yes

Yes

Yes

  • в—Џ LLDP

Yes

Yes

Yes

Yes

  • в—Џ EtherNet/IP

Yes

Yes

Yes

Yes

  • в—Џ SNMP v1

Yes

Yes

Yes

Yes

  • в—Џ SNMP v2

Yes

Yes

Yes

Yes

  • в—Џ SNMP v3

Yes

Yes

Yes

Yes

  • в—Џ IGMP (snooping/querier)

Yes

Yes

Yes

Yes

Identification & maintenance function

 

 

 

 

  • в—Џ I&M0 - device-specific information

Yes

Yes

Yes

Yes

  • в—Џ I&M1 – higher-level designation/location designation

Yes

Yes

Yes

Yes

Product functions Diagnosis

 

 

 

 

Product function

 

 

 

 

  • в—Џ Port diagnostics

Yes

Yes

Yes

Yes

  • в—Џ Statistics Packet Size

Yes

Yes

Yes

Yes

  • в—Џ Statistics packet type

Yes

Yes

Yes

Yes

  • в—Џ Error statistics

Yes

Yes

Yes

Yes

  • в—Џ SysLog

Yes

Yes

Yes

Yes

  • в—Џ loopback diagnostics

Yes

Yes

Yes

Yes

Product functions VLAN

 

 

 

 

Product function

 

 

 

 

  • в—Џ VLAN - port based

Yes

Yes

Yes

Yes

  • в—Џ VLAN - protocol-based

No

No

No

No

  • в—Џ VLAN - IP-based

No

No

No

No

  • в—Џ VLAN dynamic

No

No

No

No

Number of VLANs maximum

4 094

4 094

4 094

4 094

Product functions DHCP

 

 

 

 

Product function

 

 

 

 

  • в—Џ DHCP server

Yes

Yes

Yes

Yes

  • в—Џ DHCP client

Yes

Yes

Yes

Yes

  • в—Џ DHCP Option 82

Yes

Yes

Yes

Yes

  • в—Џ DHCP Option 66

Yes

Yes

Yes

Yes

  • в—Џ DHCP Option 67

Yes

Yes

Yes

Yes

Product functions Redundancy

 

 

 

 

Product function

 

 

 

 

  • в—Џ Ring redundancy

Yes

Yes

Yes

Yes

  • в—Џ High Speed Redundancy Protocol (HRP)

Yes

Yes

Yes

Yes

  • в—Џ high speed redundancy protocol (HRP) with redundancy manager

Yes

Yes

Yes

Yes

  • в—Џ high speed redundancy protocol (HRP) with standby redundancy

Yes

Yes

Yes

Yes

Protocol is supported Media Redundancy Protocol (MRP)

Yes

Yes

Yes

Yes

Product function

 

 

 

 

  • в—Џ media redundancy protocol (MRP) with redundancy manager

Yes

Yes

Yes

Yes

  • в—Џ redundancy procedure RSTP

Yes

Yes

Yes

Yes

  • в—Џ redundancy procedure MSTP

Yes

Yes

Yes

Yes

  • в—Џ Passive listening

Yes

Yes

Yes

Yes

Product functions Security

 

 

 

 

Product function

 

 

 

 

  • в—Џ RADIUS client

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • в—Џ SSH

Yes

Yes

Yes

Yes

  • в—Џ SSL

Yes

Yes

Yes

Yes

Product functions Time

 

 

 

 

Product function

 

 

 

 

  • в—Џ SICLOCK support

Yes

Yes

Yes

Yes

  • в—Џ NTP-client

Yes

Yes

Yes

Yes

  • в—Џ SNTP client

Yes

Yes

Yes

Yes

Protocol is supported

 

 

 

 

  • в—Џ NTP

Yes

Yes

Yes

Yes

  • в—Џ SNTP

Yes

Yes

Yes

Yes

Standards, specifications, approvals

 

 

 

 

Standard

 

 

 

 

  • в—Џ for FM

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

FM3611: Class 1, Divison 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4

  • в—Џ for hazardous zone

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X

  • в—Џ for safety from CSA and UL

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

UL 60950-1, CSA C22.2 No. 60950-1

  • в—Џ for hazardous zone from CSA and UL

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4

  • в—Џ for emitted interference

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

EN 61000-6-4 (Class A)

  • в—Џ for interference immunity

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

EN 61000-6-2

Standards, specifications, approvals CE

 

 

 

 

Certificate of suitability CE marking

Yes

Yes

Yes

Yes

Certificate of suitability RoHS conformity

Yes

Yes

Yes

Yes

Standards, specifications, approvals miscellaneous

 

 

 

 

Certificate of suitability

  • в—Џ C-Tick

Yes

Yes

Yes

Yes

  • в—Џ E1 approval

Yes

Yes

  • в—Џ e1 approval

Yes

Yes

  • в—Џ Railway application in accordance with EN 50155

No

No

Yes

Yes

  • в—Џ Railway application in accordance with EN 50124-1

No

No

Yes

Yes

  • в—Џ Fire protection in accordance with EN 45545-2

Yes

Yes

  • в—Џ KC approval

Yes

Yes

Yes

Yes

Standards, specifications, approvals product conformity

 

 

 

 

MTBF at 40 °C

48 y

48 y

48 y

35 y

Accessories

 

 

 

 

Product extension optional C-PLUG

Yes

Yes

Yes

Yes


















skener.ru

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Арматура DENDOR

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Датчики и измерители

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Регуляторы и регистраторы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Пневматическое оборудование

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Краны и Клапаны

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Измерительные приборы

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Системы беспроводного управления «умный дом»

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
Бесконтактные выключатели Конечные выключатели Оптические датчики Энкодеры

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FS - Установка умягчения

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 23

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30

Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30


Deprecated: Function eregi() is deprecated in /home/h101150-2/siemens71.ru/docs/kip/kip.php on line 30
SKW-FK - Установка обезжелезивания
Каталог оборудования 2018
Siemens Industry Catalog Drive technology Automation technology Automation systems Operator control and monitoring systems SIMATIC HMI Identification systems Industrial communication Introduction Industrial Ethernet Introduction Data communication Communication overview Topologies Network selection criteria Cabling technology Industrial media converters Layer 2 switches Overview Compact switch modules SCALANCE X-000 unmanaged SCALANCE X-100 unmanaged SCALANCE X-200 managed SCALANCE X-200 managed SIPLUS SCALANCE X-200 managed SCALANCE X-200PRO managed SCALANCE XB-200 managed SCALANCE XC-200 managed SCALANCE XP-200 managed SCALANCE XF-200 managed SCALANCE XF204-2BA (managed) SCALANCE XF204-2BA DNA (Y-switch) SCALANCE X200RNA managed SCALANCE X-200IRT managed SCALANCE X-300 managed RUGGEDCOM i800 unmanaged or managed RUGGEDCOM RS900 / M900 managed RUGGEDCOM RS950 RNA managed RUGGEDCOM RSG2100 / M2100 managed RUGGEDCOM RSG2200 / M2200 managed RUGGEDCOM RSG2300 managed RUGGEDCOM RSG2488 managed RUGGEDCOM RS8000 managed RUGGEDCOM Accessories RUGGEDCOM Technology Modules Layer 3 switches/routers Serial Device Servers Power over Ethernet Injector Industrial Ethernet Security System Interfaces SCALANCE accessories RUGGEDCOM Accessories Network management and diagnostics Network transitions Industrial Network Services Partner solutions PROFINET PROFIBUS AS-Interface IO-Link Industrial wireless communication Industrial remote communication Industrial security Industrial controls Industry software PC-based Automation Process control systems Process instrumentation Process analytics SITOP power supply Products for specific requirements Energy Building Technologies Low-Voltage controls and distribution Safety Systems - Safety Integrated Market-specific solutions Industry Services Software ... and everything else you need




  © ООО "СК ЭНЕРГО" 2007-2022
  (4872) 700-366  skenergo@mail.ru